Heart rate indices of the anaerobic threshold
The DOI matches its Crossref record.
Abstract
Although heart rate (HR) cannot be used to identify the anaerobic threshold (AT), it may be used to regulate activity intensity above or below AT. This study examined the HR response and percent maximal HR (%HRmax) at the AT in 20 young women. The AT, VO2max, and HRmax were assessed during incremental (25 W each min) cycle exercise to exhaustion. Ventilation and gas exchange were measured ever 30 s, and HR was measured each minute. Anaerobic threshold was identified by departure from linearity of the oxygen-ventilation equivalent (VEo2), pulmonary ventilation (VE), and Vco2 relative to VO2. Heart rate at AT was found by regressing HR on VO2 with individual equations. The mean (±SD) VO2max was 38.4 ± 4.7 ml·min-1·kg-1 with HRmax of 183.0 ± 8.0 bpm. Anaerobic threshold averaged 27.0 ml·min-1·kg11 (70.1% VO2max) with corresponding HR of 158.4 ± 12.4 bpm (86.3% HRmax). A zone of non-uniform work stress with respect to AT was found between 75–90% HRmax (58–75% VO2max): exercise at any intensity in this zone results in as few as one or as many as 14 subjects working above their AT. If AT represents a transition point in metabolic stress, it may be a better basis for activity prescription than an arbitrary percent VO2max or percent HRmax. Heart rate can be used to regulate activity above or below AT, but this requires individual assessment of HRAT because the correlation (r) between %HRmaxAT and %Vo2maxAT was 0.60. Exercise between 50–85% VO2max, or 70–90% HRmax results in dissimilar work stress in subjects with different AT but similar VO2max. More uniform activity prescriptions, with respect to intensity, could be attained if work is equated on the basis of AT.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Ekkekakis, P., Parfitt, G., & Petruzzello, S. J. (2011) · Sports Medicine · doi:10.2165/11590680-000000000-00000 · Cited by 1,215
Mann, T. N., Lamberts, R. P., & Lambert, M. I. (2014) · Sports Medicine · doi:10.1007/s40279-014-0197-3 · Cited by 379
Ekkekakis, P., Hall, E. E., & Petruzzello, S. J. (2005) · Journal of Sports Sciences · doi:10.1080/02640410400021492 · Cited by 371
Methods of Prescribing Relative Exercise Intensity: Physiological and Practical Considerations
Mann, T., Lamberts, R. P., & Lambert, M. I. (2013) · Sports Medicine · doi:10.1007/s40279-013-0045-x · Cited by 333
“For example, Dwyer and Bybee [16] observed that for any intensity between 58 and 75 % VO2max, some of their participants were below, and others above the AnT.”
BackgroundMyers, J., & Ashley, E. (1997) · Chest · doi:10.1378/chest.111.3.787 · Cited by 200
Metadata
- Authors
- DWYER, J., & BYBEE, R.
- Venue
- Medicine & Science in Sports & Exercise
- Published
- 1983
- Volume
- 15
- Issue
- 1
- Pages
- 72???76
- ISSN
- 0195-9131 (ISSN-L)
- OpenAlex
- W2094743847
- Cited by
- 75
- References
- 0
- FWCI
- 6.13
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Heart rate indices of the anaerobic threshold. https://app.cochat.ai/papers/10.1249/00005768-198315010-00013
- The paper
- DWYER, J., & BYBEE, R. (1983). Heart rate indices of the anaerobic threshold. Medicine & Science in Sports & Exercise. https://doi.org/10.1249/00005768-198315010-00013
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.