Hemoglobin desaturation in highly trained athletes during heavy exercise
The DOI matches its Crossref record.
Abstract
It has been generally accepted that during exercise at sea level, the pulmonary system of normal, healthy individuals is capable of maintaining arterial oxygen tension at near resting levels. However, recent evidence questions whether this generalization applies to the highly trained endurance athlete who is capable of achieving very high levels of metabolic demand. Hence, the purpose of these experiments was to examine the relationship between maximal oxygen consumption (VO2max) and arterial oxygen-hemoglobin saturation (%SaO2) during short-term heavy exercise in trained athletes and untrained individuals. Ten trained distance runners and 7 untrained males exercised at 95% of VO2max for 3 min. Minute-by-minute measurement of %SaO2 was obtained via ear oximetry. The correlation coefficients between %SaO2 and VO2max during exercise were r = -0.68, r = -0.74, and r = -0.72 (P less than 0.05) for minutes 1 through 3, respectively. In general those individuals with the highest VO2max showed the greatest decrease in %SaO2. By comparison there was no difference (P greater than 0.05) in resting %SaO2 between the trained (96.3 +/- 0.2% [SE]) and the untrained (96.3 +/- 0.4%) subjects. However, at minute 3 of exercise, %SaO2 was significantly lower (P less than 0.05) in the trained subjects (87.0 +/- 0.7%) than in the untrained subjects (92.6 +/- 0.7%). These data demonstrate that arterial desaturation occurs in healthy, highly trained endurance athletes during heavy exercise and that the level of the arterial desaturation is inversely related to VO2max.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Significance of the Velocity at &OV0312;O2max and Time to Exhaustion at this Velocity
Billat, L. V., & Koralsztein, J. P. (1996) · Sports Medicine · doi:10.2165/00007256-199622020-00004 · Cited by 380
Prevention of Cold Injuries during Exercise
Castellani, J. W., Young, A. J., Ducharme, M. B., Giesbrecht, G. G., Glickman, E., & Sallis, R. E. (2006) · Medicine & Science in Sports & Exercise · doi:10.1249/01.mss.0000241641.75101.64 · Cited by 350
Carlsen, K. H., Anderson, S. D., Bjermer, L., Bonini, S., Brusasco, V., Canonica, W., Cummiskey, J., Delgado, L., Del Giacco, S. R., Drobnic, F., et al. (2008) · Allergy · doi:10.1111/j.1398-9995.2008.01662.x · Cited by 315
Meta-analysis of arterial oxygen saturation monitoring by pulse oximetry in adults
Jensen, L. A., Onyskiw, J. E., & Prasad, N. G. N. (1998) · Heart & Lung · doi:10.1016/s0147-9563(98)90086-3 · Cited by 243
Potential errors in pulse oximetry: II. Effects of changes in saturation and signal quality*
WEBB, R. K., RALSTON, A. C., & RUNCIMAN, W. B. (1991) · Anaesthesia · doi:10.1111/j.1365-2044.1991.tb09411.x · Cited by 213
Incidence of exercise induced hypoxemia in elite endurance athletes at sea level
Powers, S. K., Dodd, S., Lawler, J., Landry, G., Kirtley, M., McKnight, T., & Grinton, S. (1988) · European Journal of Applied Physiology and Occupational Physiology · doi:10.1007/bf00417266 · Cited by 173
“The decision to use a _< 91% SaO2 as the cutoff for defining EIH was based on data which suggests that healthy untrained or moderately trained subjects generally have SaO2 values around 95% during maximal exercise (Astrand and Rodahl 1986; Williams et al. 1986).”
BackgroundMethodSelf-citationStroke volume does not plateau during graded exercise in elite male distance runners
ZHOU, B., CONLEE, R. K., JENSEN, R., FELLINGHAM, G. W., GEORGE, J. D., & GARTH FISHER, A. (2001) · Medicine and Science in Sports and Exercise · doi:10.1097/00005768-200111000-00008 · Cited by 160
The respiratory system as an exercise limiting factor in normal sedentary subjects
Boutellier, U., & Piwko, P. (1992) · European Journal of Applied Physiology and Occupational Physiology · doi:10.1007/bf00717952 · Cited by 82
Arterial hypoxemia and performance during intense exercise
Koskolou, M. D., & McKenzie, D. C. (1994) · European Journal of Applied Physiology and Occupational Physiology · doi:10.1007/bf00599246 · Cited by 37
Factors limiting maximal O2 consumption: effects of acute changes in ventilation
Ferretti, G., & di Prampero, P. E. (1995) · Respiration Physiology · doi:10.1016/0034-5687(94)00092-e · Cited by 32
Metadata
- Authors
- WILLIAMS, J. H., POWERS, S. K., & STUART, M. K.
- Venue
- Medicine & Science in Sports & Exercise
- Published
- 1986-04
- Volume
- 18
- Issue
- 2
- Pages
- 168???173
- ISSN
- 0195-9131 (ISSN-L)
- OpenAlex
- W2039762283
- Cited by
- 107
- References
- 0
- FWCI
- 5.92
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.