Effect of exercise testing protocol on parameters of aerobic function
The DOI matches its Crossref record.
Abstract
Four different patterns of increasing work rate (ramp and 1-min, 2-min, and 3-min steps) to maximum tolerance were studied in eight normal male subjects during cycle ergometer exercise testing to determine the effect of the work rate protocol on the parameters of aerobic function. The overall rate of work rate increase was kept constant. Measurements included VO2max, anaerobic threshold (AT), and the O2 uptake increase with respect to work rate increase (delta VO2/delta WR). VO2, VCO2, VE, respiratory exchange ratio (R), PETCO2, and PETO2 were calculated breath-by-breath. No significant difference was found in VO2max, AT, AT/VO2max, and delta VO2/delta WR among the four work rate protocols. Other measurements such as total work, maximal work rate, VCO2, VE, R, HR, O2 pulse, and the VO2 at which VE increases disproportionately to VCO2 (ventilatory compensation point) were also similar among the four protocols. Both the ramp and 1-min step work rate tests had no step pattern in either VO2 or VCO2, and the step pattern for the 2-min and 3-min step tests was attenuated or disappeared at work rates above AT. We conclude that the parameters of aerobic function, and other physiological responses at maximum work rate, were independent of the pattern of work rate increase, provided that the overall rate of work rate increase was the same.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
ATS/ACCP statement on cardiopulmonary exercise testing
(2003) · American Journal of Respiratory and Critical Care Medicine · doi:10.1164/rccm.167.2.211 · Cited by 3,026
ATS/ACCP statement on cardiopulmonary exercise testing
Ross, R. M. (2003) · American Journal of Respiratory and Critical Care Medicine · doi:10.1164/ajrccm.167.10.950 · Cited by 2,073
The maximally attainable V̇o2during exercise in humans: the peak vs. maximum issue
Day, J. R., Rossiter, H. B., Coats, E. M., Skasick, A., & Whipp, B. J. (2003) · Journal of Applied Physiology · doi:10.1152/japplphysiol.00024.2003 · Cited by 447
ERS statement on standardisation of cardiopulmonary exercise testing in chronic lung diseases
Radtke, T., Crook, S., Kaltsakas, G., Louvaris, Z., Berton, D., Urquhart, D. S., Kampouras, A., Rabinovich, R. A., Verges, S., Kontopidis, D., et al. (2019) · European Respiratory Review · doi:10.1183/16000617.0101-2018 · Cited by 338
Metadata
- Authors
- ZHANG, Y.-Y., JOHNSON, M. C., CHOW, N., & WASSERMAN, K.
- Venue
- Medicine and Science in Sports and Exercise
- Published
- 1991-05
- Volume
- 23
- Issue
- 5
- Pages
- 625???630
- ISSN
- 0195-9131 (ISSN-L)
- OpenAlex
- W2026248735
- Cited by
- 108
- References
- 0
- FWCI
- 2.21
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Effect of exercise testing protocol on parameters of aerobic function. https://app.cochat.ai/papers/10.1249/00005768-199105000-00016
- The paper
- ZHANG, Y.-Y., JOHNSON, M. C., CHOW, N., & WASSERMAN, K. (1991). Effect of exercise testing protocol on parameters of aerobic function. Medicine and Science in Sports and Exercise. https://doi.org/10.1249/00005768-199105000-00016
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.