Erythrocyte, plasma, and blood volume of healthy young men
The DOI matches its Crossref record.
Abstract
Insufficient data are readily available concerning the vascular fluid volumes of healthy young men. The primary purpose of this study was to develop a normative database for the erythrocyte volume, plasma volume, and blood volume of healthy young men. The secondary purposes were to relate these vascular fluid volumes to the person's body size and physical fitness level and to develop equations that enable their prediction. Fifty-one male soldiers with a mean age of 22 (range 18-35) yr and with a mean maximal aerobic power of 53 (range 42-65) ml O2.kg-1.min-1 had their lean body mass and vascular fluid volumes measured. Erythrocyte volume was measured by 51Cr, and plasma volume was measured by 125I. The findings concerning the erythrocyte volume, plasma volume, and blood volume of these young men are summarized as follows: 1) these vascular fluid volumes are accurately predicted from several indices of body size; 2) lean body mass is the anthropometric index that is most closely correlated to these vascular fluid volumes; 3) the erythrocyte volumes for a given body surface area are lower, particularly for large individuals, than values previously reported in surveys of undefined populations; 4) aerobic fitness is generally not related to vascular volumes; and 5) F-cell ratio is not related to aerobic fitness.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Dehydration: Physiology, Assessment, and Performance Effects
Cheuvront, S. N., & Kenefick, R. W. (2014) · Comprehensive Physiology · doi:10.1002/cphy.c130017 · Cited by 461
“Intracellular dehydration therefore results in a small ratio of PV to TBW losses ( ∼ 1:10), though the precise ratio may vary according to the magnitude (small vs. large losses) and mode (passive vs. active) of dehydration (184, 315).”
Heat acclimation improves exercise performance
Lorenzo, S., Halliwill, J. R., Sawka, M. N., & Minson, C. T. (2010) · Journal of Applied Physiology · doi:10.1152/japplphysiol.00495.2010 · Cited by 425
Self-citationJosé, G.-A., Mora-Rodríguez, R., Below, P. R., & Coyle, E. F. (1997) · Journal of Applied Physiology · doi:10.1152/jappl.1997.82.4.1229 · Cited by 390
Sawka, M. N., Cheuvront, S. N., & Carter, R. (2005) · Nutrition Reviews · doi:10.1111/j.1753-4887.2005.tb00152.x · Cited by 336
Self-citationTaylor, N. A. S. (2014) · Comprehensive Physiology · doi:10.1002/cphy.c130022 · Cited by 331
Metadata
- Authors
- SAWKA, M. N., YOUNG, A. J., PANDOLF, K. B., DENNIS, R. C., & VALERI, C. R.
- Venue
- Medicine & Science in Sports & Exercise
- Published
- 1992-04
- Volume
- 24
- Issue
- 4
- Pages
- 447???453
- ISSN
- 0195-9131 (ISSN-L)
- OpenAlex
- W1983277581
- Cited by
- 96
- References
- 0
- FWCI
- 0.00
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Erythrocyte, plasma, and blood volume of healthy young men. https://app.cochat.ai/papers/10.1249/00005768-199204000-00009
- The paper
- SAWKA, M. N., YOUNG, A. J., PANDOLF, K. B., DENNIS, R. C., & VALERI, C. R. (1992). Erythrocyte, plasma, and blood volume of healthy young men. Medicine & Science in Sports & Exercise. https://doi.org/10.1249/00005768-199204000-00009
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.