Dynamic and steady-state ventilatory and gas exchange responses to arm exercise
The DOI matches its Crossref record.
Abstract
Previous studies have suggested that, for the same power output, arm exercise requires higher oxygen uptake (VO2), carbon dioxide output (VCO2), and ventilation (VE) than leg exercise and that response kinetics are slower. To evaluate these differences, four healthy subjects performed a total of 95 arm cranking tests. Each subject performed several tests at each of three or four power outputs spaced evenly below the maximum the subject could sustain (average = 53 W). Breath-by-breath responses to identical stimuli were averaged. End-exercise blood lactate was determined at each power output. Responses were compared to leg exercise responses in these subjects (J. Appl. Physiol. 67:547-555, 1989). For power outputs unassociated with lactic acidosis, differences between steady-state VO2, VCO2, and VE responses for arm and leg exercise were not significant. At higher power outputs, the higher VO2, VCO2, and VE during arm exercise were well correlated with higher lactate. For power outputs not engendering lactic acidosis, the time constants (tau) for VO2, VCO2 and VE were not greatly different for arm than for leg exercise. For each variable, at higher power outputs tau became longer by an amount correlated with higher lactate level. Like leg exercise, the slower kinetics of VO2 and VE (but not VCO2) at higher power outputs were well described as a superimposed slower component. We conclude that both dynamic and steady-state responses of VE and gas exchange to arm exercise do not differ substantially from those to leg exercise so long as the power output does not elevate blood lactate.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
ATS/ACCP statement on cardiopulmonary exercise testing
(2003) · American Journal of Respiratory and Critical Care Medicine · doi:10.1164/rccm.167.2.211 · Cited by 3,026
ATS/ACCP statement on cardiopulmonary exercise testing
Ross, R. M. (2003) · American Journal of Respiratory and Critical Care Medicine · doi:10.1164/ajrccm.167.10.950 · Cited by 2,073
Poole, D. C., & Jones, A. M. (2012) · Comprehensive Physiology · doi:10.1002/cphy.c100072 · Cited by 514
Oxygen Uptake Kinetics during Exercise
Xu, F., & Rhodes, E. C. (1999) · Sports Medicine · doi:10.2165/00007256-199927050-00003 · Cited by 258
Coupling of external to cellular respiration during exercise: the wisdom of the body revisited
Wasserman, K. (1994) · American Journal of Physiology-Endocrinology and Metabolism · doi:10.1152/ajpendo.1994.266.4.e519 · Cited by 121
Self-citation
Metadata
- Authors
- CASABURI, R., BARSTOW, T. J., ROBINSON, T., & WASSERMAN, K.
- Venue
- Medicine & Science in Sports & Exercise
- Published
- 1992-12
- Volume
- 24
- Issue
- 12
- Pages
- 1365???1374
- ISSN
- 0195-9131 (ISSN-L)
- OpenAlex
- W2043056314
- Cited by
- 75
- References
- 0
- FWCI
- 2.91
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Dynamic and steady-state ventilatory and gas exchange responses to arm exercise. https://app.cochat.ai/papers/10.1249/00005768-199212000-00010
- The paper
- CASABURI, R., BARSTOW, T. J., ROBINSON, T., & WASSERMAN, K. (1992). Dynamic and steady-state ventilatory and gas exchange responses to arm exercise. Medicine & Science in Sports & Exercise. https://doi.org/10.1249/00005768-199212000-00010
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.