The simplified V-slope method of detecting the gas exchange threshold
The DOI matches its Crossref record.
Abstract
A simplified V-slope method was used to visually determine the first point of departure from linearity of carbon dioxide output (VCO2) plotted against oxygen uptake (VO2). The point at which VCO2 departed from a line with a slope equal to 1.00 was visually selected as the gas exchange threshold during incremental exercise. The simplified method of threshold detection was compared with a computerized V-slope method. Both methods were used to determine the gas exchange threshold during incremental cycling (10 W.min-1) in 17 untrained female subjects. The thresholds occurred at 41.1% and 45.1% of VO2max using the computerized and simplified V-slope methods, respectively. The correlation between the oxygen uptake measured at the threshold using the two methods was 0.95. Power output, VO2, and heart rate values determined at the gas exchange threshold using the simplified V-slope method were significantly higher than the corresponding values obtained using the computerized V-slope method. The simplified V-slope method consistently placed the gas exchange threshold at the work rate that was about 10 W above the power output determined by the computerized method. Although the two methods were highly correlated, the simplified V-slope method tended to overestimate threshold values determined from a computerized gas exchange method.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Bizjak, D. A., Tomschi, F., Bales, G., Nader, E., Romana, M., Connes, P., Bloch, W., & Grau, M. (2020) · Journal of Sport and Health Science · doi:10.1016/j.jshs.2019.02.002 · Cited by 49
Siervo, M., Oggioni, C., Jakovljevic, D. G., Trenell, M., Mathers, J. C., Houghton, D., Celis-Morales, C., Ashor, A. W., Ruddock, A., Ranchordas, M., et al. (2016) · Nutrition Research · doi:10.1016/j.nutres.2016.11.004 · Cited by 37
El-Ashker, S., Chaabene, H., Negra, Y., Prieske, O., & Granacher, U. (2018) · Sports · doi:10.3390/sports6040119 · Cited by 28
“The VO2AT was calculated using the gas exchange V-slope in addition to the ventilatory techniques, as described previously [18,19].”
MethodContreras-Briceño, F., Espinosa-Ramirez, M., Keim-Bagnara, V., Carreño-Román, M., Rodríguez-Villagra, R., Villegas-Belmar, F., Viscor, G., Gabrielli, L., Andía, M. E., Araneda, O. F., et al. (2022) · Life · doi:10.3390/life12030444 · Cited by 17
“VO2 [24,44,45], breakpoint at heart-rate variability [46–50], or lactate blood level curves [11,41,51]; however, in order to diminish the variability inter- and intra- evaluator, we chose the method widely used for exercise”
Metadata
- Authors
- SCHNEIDER, D. A., PHILLIPS, S. E., & STOFFOLANO, S.
- Venue
- Medicine & Science in Sports & Exercise
- Published
- 1993-08
- Volume
- 25
- Issue
- 10
- Pages
- 1180???1184
- ISSN
- 0195-9131 (ISSN-L)
- OpenAlex
- W2103421273
- Cited by
- 153
- References
- 0
- FWCI
- 4.88
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: The simplified V-slope method of detecting the gas exchange threshold. https://app.cochat.ai/papers/10.1249/00005768-199310000-00015
- The paper
- SCHNEIDER, D. A., PHILLIPS, S. E., & STOFFOLANO, S. (1993). The simplified V-slope method of detecting the gas exchange threshold. Medicine & Science in Sports & Exercise. https://doi.org/10.1249/00005768-199310000-00015
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.