Body composition by DXA: tried and true?
The DOI matches its Crossref record.
Abstract
Dual-energy x-ray absorptiometry (DXA) is unquestionably the method of choice for the assessment of bone mass. Recent generations of DXA instruments also have the capability of assessing soft tissue mass, thereby providing a three-compartment model of body composition, i.e., bone mineral, fat, and bone-free lean masses. Although hydrodensitometry has long been considered the reference method of assessing body composition, assumptions regarding the constancy of the constituents of fat-free mass may compromise its validity in some populations. Because DXA appears to be less dependent on assumptions regarding biological consistency, it is possible that it has the potential to provide a more accurate assessment of body composition across populations than does hydrodensitometry, and that it should be considered the reference method. DXA has been shown to provide precise measures of body composition, but it remains questionable as to whether those measures are accurate. Contributing to the uncertainty regarding validity is the variability among manufacturers of DXA instruments in the methods of calibration, data acquisition, and data analysis. Although DXA holds great promise in becoming the criterion method of assessing body composition, and has been promoted as such by some investigators, available data indicate that this endorsement is premature.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
ACSM Position Stand: The Female Athlete Triad
Otis, C. L., Drinkwater, B., Johnson, M., Loucks, A., & Wilmore, J. (1997) · Medicine & Science in Sports & Exercise · doi:10.1097/00005768-199705000-00037 · Cited by 515
Body Composition Methods: Comparisons and Interpretation
Duren, D. L., Sherwood, R. J., Czerwinski, S. A., Lee, M., Choh, A. C., Siervogel, R. M., & Chumlea, W. C. (2008) · Journal of Diabetes Science and Technology · doi:10.1177/193229680800200623 · Cited by 451
Nana, A., Slater, G. J., Stewart, A. D., & Burke, L. M. (2015) · International Journal of Sport Nutrition and Exercise Metabolism · doi:10.1123/ijsnem.2013-0228 · Cited by 372
Misra, M., Aggarwal, A., Miller, K. K., Almazan, C., Worley, M., Soyka, L. A., Herzog, D. B., & Klibanski, A. (2004) · Pediatrics · doi:10.1542/peds.2004-0540 · Cited by 349
In vivo validation of whole body composition estimates from dual-energy X-ray absorptiometry
Prior, B. M., Cureton, K. J., Modlesky, C. M., Evans, E. M., Sloniger, M. A., Saunders, M., & Lewis, R. D. (1997) · Journal of Applied Physiology · doi:10.1152/jappl.1997.83.2.623 · Cited by 317
Metadata
- Authors
- KOHRT, W. M.
- Venue
- Medicine & Science in Sports & Exercise
- Published
- 1995-10
- Volume
- 27
- Issue
- 10
- Pages
- 1349???1353
- ISSN
- 0195-9131 (ISSN-L)
- OpenAlex
- W2086949959
- Cited by
- 143
- References
- 0
- FWCI
- 6.33
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Body composition by DXA: tried and true? https://app.cochat.ai/papers/10.1249/00005768-199510000-00001
- The paper
- KOHRT, W. M. (1995). Body composition by DXA: tried and true? Medicine & Science in Sports & Exercise. https://doi.org/10.1249/00005768-199510000-00001
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.