The DOI matches its Crossref record.
Evaluation of a new air displacement plethysmograph for measuring human body composition
Abstract
A new air displacement plethysmograph, the BOD POD (BP), was evaluated in comparison to hydrostatic weighing (HW). Sixty-eight adult subjects (26 F, 42 M) varying widely in age (range 20-56 yr), ethnicity, and fatness participated in this study. Same-day test-retest reliability was assessed in a subsample of 16 subjects (9 F, 7 M) and validity was assessed in all subjects (N = 68). The test-retest coefficients of variation (CV) for %FAT measured by BP (%FATBP) and HW (%FATHW) were not significantly different (1.7% +/- 1.1% and 2.3% +/- 1.9% for BP and HW, respectively (mean +/- SD)), indicating excellent reliability for both methods. Validity of percent fat measured by the BP (%FATBP) was also excellent. The mean difference in %FAT (BP - HW) was -0.3 +/- 0.2 (SEM), with a 95% confidence interval of -0.6 to 0 %FAT. The regression equation (%FATHW = 1.86 + 0.94 %FATBP; r2 = 0.93, SEE = 1.81) was not significantly different from the line of identity (%FATHW = %FATBP), and did not differ by gender. These findings indicate that the BOD POD is a highly reliable and valid method for determining %FAT in adult humans in comparison to HW. This new method has several advantages over HW in that it is quick, relatively simple to operate and may be able to accommodate special populations such as the obese, elderly, and disabled.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Garvey, W. T., Mechanick, J. I., Brett, E. M., Garber, A. J., Hurley, D. L., Jastreboff, A. M., Nadolsky, K., Pessah-Pollack, R., & Plodkowski, R. (2016) · Endocrine Practice · doi:10.4158/ep161365.gl · Cited by 1,914
Body-composition assessment via air-displacement plethysmography in adults and children: a review
Fields, D. A., Goran, M. I., & McCrory, M. A. (2002) · The American Journal of Clinical Nutrition · doi:10.1093/ajcn/75.3.453 · Cited by 638
Self-citationLean Tissue Imaging: A New Era for Nutritional Assessment and Intervention
Prado, C. M. M., & Heymsfield, S. B. (2014) · Journal of Parenteral and Enteral Nutrition · doi:10.1177/0148607114550189 · Cited by 550
Human Body Composition: Advances in Models and Methods
B. Heymsfield, S., Wang, Z., Baumgartner, R. N., & Ross, R. (1997) · Annual Review of Nutrition · doi:10.1146/annurev.nutr.17.1.527 · Cited by 527
Endocrine Control of Body Composition in Infancy, Childhood, and Puberty
Veldhuis, J. D., Roemmich, J. N., Richmond, E. J., Rogol, A. D., Lovejoy, J. C., Sheffield-Moore, M., Mauras, N., & Bowers, C. Y. (2005) · Endocrine Reviews · doi:10.1210/er.2003-0038 · Cited by 452
Metadata
- Authors
- MCCRORY, M. A., GOMEZ, T. D., BERNAUER, E. M., & MOL??, P. A.
- Venue
- Medicine & Science in Sports & Exercise
- Published
- 1995-12
- Volume
- 27
- Issue
- 12
- Pages
- 1686???1691
- ISSN
- 0195-9131 (ISSN-L)
- OpenAlex
- W2084946461
- Cited by
- 512
- References
- 0
- FWCI
- 2.53
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Evaluation of a new air displacement plethysmograph for measuring human body composition. https://app.cochat.ai/papers/10.1249/00005768-199512000-00016
- The paper
- MCCRORY, M. A., GOMEZ, T. D., BERNAUER, E. M., & MOL??, P. A. (1995). Evaluation of a new air displacement plethysmograph for measuring human body composition. Medicine & Science in Sports & Exercise. https://doi.org/10.1249/00005768-199512000-00016
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.