CoChat

Laboratory Calibration and Validation of the Biotrainer and Actitrac Activity Monitors

WELK, GREGORY J., ALMEIDA, JOAO, MORSS, GINA · 2003 · Medicine & Science in Sports & Exercise
Cited by 62

The DOI matches its Crossref record; 2 of the 2 references it cites were found in a registry or an index.

Abstract

PURPOSE: The Biotrainer and Actitrac activity monitors (IM Systems) offer potential research advantages over existing accelerometry-based activity monitors, but they have not been tested under controlled conditions. The purpose of this study was to develop and test laboratory-based prediction equations for both monitors to estimate energy expenditure (EE) for walking/running movements. METHODS: Participants in the study wore a Biotrainer and Actitrac monitor on both hips and completed three paced bouts on the treadmill (3, 4, and 6 mph for 6 min each). Metabolic data collected using an indirect calorimetry system were used as the criterion measure. Multiple regression techniques were performed to develop prediction equations, and these equations were then applied to data from a separate sample for cross-validation purposes. Reliability was also examined. RESULTS: The correlations between the raw counts from each monitor and the measured metabolic variables ranged from r = 0.74-0.88 for the Biotrainer and from r = 0.81-0.91 for the Actitrac. The equations predicting EE (kcal x min-1) from counts yielded strong validation results for both the Biotrainer (R2 = 0.88, SEE = 1.47) and the Actitrac (R2 = 0.91, SEE = 1.24). When used on the cross-validation sample, the correlations between measured and predicted EE were r = 0.93 (Biotrainer) and r = 0.94 (Actitrac). Intraclass reliability coefficients computed between the left and right monitors ranged from 0.60 to 0.71 (Biotrainer) and 0.80 to 0.87 (Actitrac). When the equation developed from one side was applied to data from the monitor on the other side, there were no significant differences in predicted and measured EE for most comparisons. CONCLUSION: The results support the validity of Biotrainer and Actitrac monitors for estimating energy expenditure under controlled conditions.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1249/01.mss.0000069525.56078.22

Cites

2 of 2 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 2 references

Cited by

See all 62

Metadata

Authors
WELK, G. J., ALMEIDA, J., & MORSS, G.
Venue
Medicine & Science in Sports & Exercise
Published
2003-06
Volume
35
Issue
6
Pages
1057-1064
ISSN
0195-9131 (ISSN-L)
OpenAlex
W2020817928
Cited by
62
References
2
FWCI
2.53
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Laboratory Calibration and Validation of the Biotrainer and Actitrac Activity Monitors. https://app.cochat.ai/papers/10.1249/01.mss.0000069525.56078.22
The paper
WELK, G. J., ALMEIDA, J., & MORSS, G. (2003). Laboratory Calibration and Validation of the Biotrainer and Actitrac Activity Monitors. Medicine & Science in Sports & Exercise. https://doi.org/10.1249/01.mss.0000069525.56078.22

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.