Laboratory Calibration and Validation of the Biotrainer and Actitrac Activity Monitors
The DOI matches its Crossref record; 2 of the 2 references it cites were found in a registry or an index.
Abstract
PURPOSE: The Biotrainer and Actitrac activity monitors (IM Systems) offer potential research advantages over existing accelerometry-based activity monitors, but they have not been tested under controlled conditions. The purpose of this study was to develop and test laboratory-based prediction equations for both monitors to estimate energy expenditure (EE) for walking/running movements. METHODS: Participants in the study wore a Biotrainer and Actitrac monitor on both hips and completed three paced bouts on the treadmill (3, 4, and 6 mph for 6 min each). Metabolic data collected using an indirect calorimetry system were used as the criterion measure. Multiple regression techniques were performed to develop prediction equations, and these equations were then applied to data from a separate sample for cross-validation purposes. Reliability was also examined. RESULTS: The correlations between the raw counts from each monitor and the measured metabolic variables ranged from r = 0.74-0.88 for the Biotrainer and from r = 0.81-0.91 for the Actitrac. The equations predicting EE (kcal x min-1) from counts yielded strong validation results for both the Biotrainer (R2 = 0.88, SEE = 1.47) and the Actitrac (R2 = 0.91, SEE = 1.24). When used on the cross-validation sample, the correlations between measured and predicted EE were r = 0.93 (Biotrainer) and r = 0.94 (Actitrac). Intraclass reliability coefficients computed between the left and right monitors ranged from 0.60 to 0.71 (Biotrainer) and 0.80 to 0.87 (Actitrac). When the equation developed from one side was applied to data from the monitor on the other side, there were no significant differences in predicted and measured EE for most comparisons. CONCLUSION: The results support the validity of Biotrainer and Actitrac monitors for estimating energy expenditure under controlled conditions.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Calibration of the Computer Science and Applications, Inc. accelerometer
FREEDSON, P. S., MELANSON, E., & SIRARD, J. (1998) · Medicine & Science in Sports & Exercise · doi:10.1097/00005768-199805000-00021 · Cited by 3,825
Validity of the computer science and applications (CSA) activity monitor in children
TROST, S. G., WARD, D. S., MOOREHEAD, S. M., WATSON, P. D., RINER, W., & BURKE, J. R. (1998) · Medicine & Science in Sports & Exercise · doi:10.1097/00005768-199804000-00023 · Cited by 769
Cited by
Conducting accelerometer-based activity assessments in field-based research
TROST, S. G., MCIVER, K. L., & PATE, R. R. (2005) · Medicine & Science in Sports & Exercise · doi:10.1249/01.mss.0000185657.86065.98 · Cited by 2,033
Martínez-González, M. A., López-Fontana, C., Varo, J. J., Sánchez-Villegas, A., & Martinez, J. A. (2005) · Public Health Nutrition · doi:10.1079/phn2005745 · Cited by 586
Defining Accelerometer Thresholds for Activity Intensities in Adolescent Girls
The University of North Carolina at Chapel Hill University Libraries (2020) · Carolina Digital Repository (University of North Carolina at Chapel Hill) · doi:10.17615/zfsn-y805 · Cited by 496
Validity of Consumer-Based Physical Activity Monitors
LEE, J.-M., KIM, Y., & WELK, G. J. (2014) · Medicine & Science in Sports & Exercise · doi:10.1249/mss.0000000000000287 · Cited by 401
“, ActiGraph and ActiCal) have typically employed treadmill equations that have been shown to underestimate EE with an estimated range from 31 to 67% lower than measured values (13, 22).”
BackgroundSelf-citationDowd, K. P., Szeklicki, R., Minetto, M. A., Murphy, M. H., Polito, A., Ghigo, E., van der Ploeg, H., Ekelund, U., Maciaszek, J., Stemplewski, R., et al. (2018) · International Journal of Behavioral Nutrition and Physical Activity · doi:10.1186/s12966-017-0636-2 · Cited by 385
“Study methodologies included the wearing of devices over the left and right hip [337, 370, 385, 387, 406, 413, 415, 417], over the hip and lower back [409], the wearing of devices side by side at the same location on the hip [301, 344, 411, 414, 416–418], devices worn at 3 intercostal space and just below the apex of…”
Method
Metadata
- Authors
- WELK, G. J., ALMEIDA, J., & MORSS, G.
- Venue
- Medicine & Science in Sports & Exercise
- Published
- 2003-06
- Volume
- 35
- Issue
- 6
- Pages
- 1057-1064
- ISSN
- 0195-9131 (ISSN-L)
- OpenAlex
- W2020817928
- Cited by
- 62
- References
- 2
- FWCI
- 2.53
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Laboratory Calibration and Validation of the Biotrainer and Actitrac Activity Monitors. https://app.cochat.ai/papers/10.1249/01.mss.0000069525.56078.22
- The paper
- WELK, G. J., ALMEIDA, J., & MORSS, G. (2003). Laboratory Calibration and Validation of the Biotrainer and Actitrac Activity Monitors. Medicine & Science in Sports & Exercise. https://doi.org/10.1249/01.mss.0000069525.56078.22
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.