Technical Variability of the RT3 Accelerometer
The DOI matches its Crossref record; 2 of the 2 references it cites were found in a registry or an index.
Abstract
PURPOSE: To evaluate the technical performance of the RT3 triaxial accelerometer. METHODS: Twenty-three RT3 accelerometers were subjected to a specific vibration along each sensitive axis in isolation, using a motorized vibration table that produced frequencies of 2.1, 5.1, and 10.2 Hz, respectively. Data were analyzed for frequency and axis effects and inter- and intra-instrument variability. RESULTS: ANOVA showed a frequency by axis interaction (F2.1,36.8 = 19.9, P < 0.001). Post hoc tests revealed the Y axis count to be significantly higher than the X and Z axes counts at 5.1 and 10.2 Hz. There was no difference in counts between axes at 2.1 Hz. Interinstrument coefficients of variation (CV) decreased as frequency increased (21.9 to 26.7% at 2.1 Hz, 6.3 to 9.0% at 5.1 Hz, and 4.2 to 7.2% at 10.2 Hz). The intraclass correlation (ICC) between RT3s was 0.99, regardless of the axis. Intra-instrument CV also decreased as frequency increased (2.1 to 56.2%, 0.3 to 2.5%, and 0.2 to 2.9% at 2.1, 5.1, and 10.2 Hz, respectively. CONCLUSION: There were no differences in counts recorded on the X, Y, and Z axes at 2.1 Hz; however, the counts recorded along the Y axis were significantly higher than the counts at the X and Z axes at 5.1 and 10.2 Hz. Due to large coefficients of variation for both inter- and intra-instrument variability at 2.1 Hz, testing the inter- and intra-instrument variability of the accelerometers before use is recommended.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Physical Fitness and All-Cause Mortality: A Prospective Study of Healthy Men and Women
Blair, S. N. (1989) · JAMA · doi:10.1001/jama.1989.03430170057028 · Cited by 2,658
Eston, R. G., Rowlands, A. V., & Ingledew, D. K. (1998) · Journal of Applied Physiology · doi:10.1152/jappl.1998.84.1.362 · Cited by 643
Self-citation
Cited by
Conducting accelerometer-based activity assessments in field-based research
TROST, S. G., MCIVER, K. L., & PATE, R. R. (2005) · Medicine & Science in Sports & Exercise · doi:10.1249/01.mss.0000185657.86065.98 · Cited by 2,033
Strath, S. J., Kaminsky, L. A., Ainsworth, B. E., Ekelund, U., Freedson, P. S., Gary, R. A., Richardson, C. R., Smith, D. T., & Swartz, A. M. (2013) · Circulation · doi:10.1161/01.cir.0000435708.67487.da · Cited by 1,029
The Technology of Accelerometry-Based Activity Monitors: Current and Future
CHEN, K. Y., & BASSETT, D. R. (2005) · Medicine & Science in Sports & Exercise · doi:10.1249/01.mss.0000185571.49104.82 · Cited by 996
Validation of the GENEA Accelerometer
ESLIGER, D. W., ROWLANDS, A. V., HURST, T. L., CATT, M., MURRAY, P., & ESTON, R. G. (2011) · Medicine & Science in Sports & Exercise · doi:10.1249/mss.0b013e31820513be · Cited by 625
Self-citationAssessment of Physical Activity and Energy Expenditure: An Overview of Objective Measures
Hills, A. P., Mokhtar, N., & Byrne, N. M. (2014) · Frontiers in Nutrition · doi:10.3389/fnut.2014.00005 · Cited by 575
Metadata
- Authors
- POWELL, S. M., JONES, D. I., & ROWLANDS, A. V.
- Venue
- Medicine & Science in Sports & Exercise
- Published
- 2003-10
- Volume
- 35
- Issue
- 10
- Pages
- 1773-1778
- ISSN
- 0195-9131 (ISSN-L)
- OpenAlex
- W1966659385
- Cited by
- 109
- References
- 2
- FWCI
- 1.63
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.