CoChat

Validation of the GENEA Accelerometer

Open access
ESLIGER, DALE W., ROWLANDS, ANN V., HURST, TINA L., CATT, MICHAEL, MURRAY, PETER, ESTON, ROGER G. · 2011 · Medicine & Science in Sports & Exercise

The DOI matches its Crossref record; 32 of the 32 references it cites were found in a registry or an index.

Abstract

PURPOSE: The study aims were: 1) to assess the technical reliability and validity of the GENEA using a mechanical shaker; 2) to perform a GENEA value calibration to develop thresholds for sedentary and light-, moderate-, and vigorous-intensity physical activity; and 3) to compare the intensity classification of the GENEA with two widely used accelerometers. METHODS: A total of 47 GENEA accelerometers were attached to a shaker and vertically accelerated, generating 15 conditions of varying acceleration and/or frequency. Reliability was calculated using SD and intrainstrument and interinstrument coefficients of variation, whereas validity was assessed using Pearson correlation with the shaker acceleration as the criterion. Next, 60 adults wore a GENEA on each wrist and on the waist (alongside an ActiGraph and RT3 accelerometer) while completing 10-12 activity tasks. A portable metabolic gas analyzer provided the criterion measure of physical activity. Analyses involved the use of Pearson correlations to establish criterion and concurrent validity and receiver operating characteristic curves to establish intensity cut points. RESULTS: The GENEA demonstrated excellent technical reliability (CVintra = 1.4%, CVinter = 2.1%) and validity (r = 0.98, P < 0.001) using the mechanical shaker. The GENEA demonstrated excellent criterion validity using VO2 as the criterion (left wrist, r = 0.86; right wrist, r = 0.83; waist, r = 0.87), on par with the waist-worn ActiGraph and RT3. The GENEA demonstrated excellent concurrent validity compared with the ActiGraph (r = 0.92) and the RT3 (r = 0.97). The waist-worn GENEA had the greatest classification accuracy (area under the receiver operating characteristic curve (AUC) = 0.95), followed by the left (AUC = 0.93) and then the right wrist (AUC = 0.90). The accuracy of the waist-worn GENEA was virtually identical with that of the ActiGraph (AUC = 0.94) and RT3 (AUC = 0.95). CONCLUSION: The GENEA is a reliable and valid measurement tool capable of classifying the intensity of physical activity in adults.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1249/mss.0b013e31820513be

Cites

32 of 32 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Claims other papers make about this one

Each is checked against this paper’s own text: does it say what the citing paper says it does?

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 32 references

Cited by

See all 649

Metadata

Authors
ESLIGER, D. W., ROWLANDS, A. V., HURST, T. L., CATT, M., MURRAY, P., & ESTON, R. G.
Affiliations
  • University of Exeter (GB)
  • Unilever (United Kingdom) (GB)
Venue
Medicine & Science in Sports & Exercise
Published
2011-06
Volume
43
Issue
6
Pages
1085-1093
ISSN
0195-9131 (ISSN-L)
OpenAlex
W2084103512
Cited by
625
References
32
Citations by year
2026: 25 · 2025: 37 · 2024: 57 · 2023: 57 · 2022: 35 · 2021: 66 · 2020: 61 · 2019: 60 · 2018: 54 · 2017: 44 · 2016: 35 · 2015: 27 · 2014: 29 · 2013: 18 · 2012: 12
FWCI
7.58
Type
journal article
Language
en
Open access
Licence
cc-by-nc-nd
Locations
  • Medicine & Science in Sports & Exercise (publishedVersion)
  • PubMed (publishedVersion)
  • Loughborough University Research Repository (Loughborough University) (submittedVersion, cc-by-nc-nd)
  • Loughborough University Institutional Repository (Loughborough University) (submittedVersion, cc-by-nc-nd)
Topics
  • Health Sciences › Medicine › Public Health, Environmental and Occupational Health › Physical Activity and Health
  • Physical Sciences › Computer Science › Computer Vision and Pattern Recognition › Context-Aware Activity Recognition Systems
  • Health Sciences › Medicine › Physiology (medical) › Cardiovascular and exercise physiology
Keywords
accelerometer validation, physical activity intensity classification, sedentary behavior, criterion validity, concurrent validity, ActiGraph, VO2
MeSH terms
Acceleration, Adult, Aged, Female, Humans, Male, Middle Aged, Motor Activity, ROC Curve, Software, Reproducibility of Results, Monitoring, Ambulatory

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Validation of the GENEA Accelerometer. https://app.cochat.ai/papers/10.1249/mss.0b013e31820513be
The paper
ESLIGER, D. W., ROWLANDS, A. V., HURST, T. L., CATT, M., MURRAY, P., & ESTON, R. G. (2011). Validation of the GENEA Accelerometer. Medicine & Science in Sports & Exercise. https://doi.org/10.1249/mss.0b013e31820513be

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.