Minimum Weight Prediction Methods Cross-Validated by the Four-Component Model
The DOI matches its Crossref record; 2 of the 2 references it cites were found in a registry or an index.
Abstract
UNLABELLED: The National Collegiate Athletic Association (NCAA) requires prediction of minimum weight (MW) for collegiate wrestlers. The rule was implemented to minimize unhealthy weight loss practices and requires assessment of body composition before the competitive season. PURPOSE: This study cross-validated the body composition methods of dual energy x-ray absorptiometry (DXA), leg-to-leg bioelectrical impedance analysis (BIA), hydrostatic weighing (HW), and skinfolds (SF) for predicting MW using a four-component criterion (4C). METHODS: Criterion MW was calculated by the 4C model using independent measurement of body density (BD), bone mineral content (BMC), and total body water (TBW). Subjects were 53 Division I athletes from the University of Wisconsin (mean +/- SD; age = 19.7 +/- 1.3 yr, height = 176.2 +/- 7.4 cm, weight = 75.6 +/- 8.9 kg). Accuracy, precision, and systematic bias were examined in the predictions. RESULTS: There were no significant differences in mean MW from HW (70.5 +/- 7.3 kg, P = 0.57), SF (70.5 +/- 7.2 kg, P = 0.29) BIA (70.6 +/- 7.6 kg, P = 0.39), DXA (70.3 +/- 7.5, P = 0.97), and the 4C criterion (70.3 +/- 7.4 kg). The regression for the relationships between 4C and HW (y = 0.994 x HW + 0.077 kg), 4C and SF (y = 1.003 x SF-0.437 kg), 4C and DXA (y = 0.942 x DXA + 4.034 kg), and 4C and BIA (y = 0.896 x BIA + 6.987 kg) did not significantly deviate from the line of identity. Pure error (PE) values ranged from 1.34 kg for HW to 3.08 kg for BIA. CONCLUSION: Comparable means, high correlations, regression lines that did not significantly deviate from the line of identity, and no systematic bias were found. However, the methods differed widely in precision. The best precision, based on SEE and PE values, were seen in the HW and SF methods. In conclusion, this rigorous four-component cross-validation study supports the NCAA methods as the most accurate and precise MW prediction methods in this sample.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Measurement in Medicine: The Analysis of Method Comparison Studies
Altman, D. G., & Bland, J. M. (1983) · The Statistician · doi:10.2307/2987937 · Cited by 4,300
Validation of tetrapolar bioelectrical impedance method to assess human body composition
Lukaski, H. C., Bolonchuk, W. W., Hall, C. B., & Siders, W. A. (1986) · Journal of Applied Physiology · doi:10.1152/jappl.1986.60.4.1327 · Cited by 1,370
Cited by
Exercise and Fluid Replacement
(2007) · Medicine & Science in Sports & Exercise · doi:10.1249/mss.0b013e31802ca597 · Cited by 1,497
Nana, A., Slater, G. J., Stewart, A. D., & Burke, L. M. (2015) · International Journal of Sport Nutrition and Exercise Metabolism · doi:10.1123/ijsnem.2013-0228 · Cited by 372
Carrel, A. L., Clark, R. R., Peterson, S. E., Nemeth, B. A., Sullivan, J., & Allen, D. B. (2005) · Archives of Pediatrics & Adolescent Medicine · doi:10.1001/archpedi.159.10.963 · Cited by 318
Self-citationHangartner, T. N., Warner, S., Braillon, P., Jankowski, L., & Shepherd, J. (2013) · Journal of Clinical Densitometry · doi:10.1016/j.jocd.2013.08.007 · Cited by 242
“5% (56) Fat mass Various review article 0.”
BackgroundInfluentialMoon, J. R. (2013) · European Journal of Clinical Nutrition · doi:10.1038/ejcn.2012.165 · Cited by 237
Metadata
- Authors
- CLARK, R. R., BARTOK, C., SULLIVAN, J. C., & SCHOELLER, D. A.
- Venue
- Medicine & Science in Sports & Exercise
- Published
- 2004-04
- Volume
- 36
- Issue
- 4
- Pages
- 639-647
- ISSN
- 0195-9131 (ISSN-L)
- OpenAlex
- W2080733648
- Cited by
- 45
- References
- 2
- FWCI
- 1.52
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.