Student or educator? Sign up with your school email and get 6 months of Pro free.
Cited by 362

The DOI matches its Crossref record; 1 of the 1 references it cites were found in a registry or an index.

Evaluation of the SenseWear Pro Armband™ to Assess Energy Expenditure during Exercise

JAKICIC, JOHN M., MARCUS, MARSHA, GALLAGHER, KARA I., RANDALL, COLBY, THOMAS, ERIN, GOSS, FREDRIC L., ROBERTSON, ROBERT J.·2004·Medicine & Science in Sports & Exercise

Abstract

PURPOSE: To assess the accuracy of the SenseWear Pro Armband for estimating energy expenditure during exercise. METHODS: : Forty subjects (age = 23.2 +/- 3.8 yr; body mass index = 23.8 +/- 3.1 kg x m) performed four exercises (walking, cycling, stepping, arm ergometry) with each exercise lasting 20-30 min and workload increasing at 10-min intervals. Subjects wore the SenseWear Pro Armband on the right arm, and energy expenditure was estimated using proprietary equations developed by the manufacturer. Estimated energy expenditure from the SenseWear Pro Armband was compared with energy expenditure determined from indirect open-circuit calorimetry, which served as the criterion measure. RESULTS: : When a generalized proprietary algorithm was applied to the data, the SenseWear Pro Armband significantly underestimated total energy expenditure by 14.9 +/- 17.5 kcal (6.9 +/- 8.5%) during walking exercise, 32.4 +/- 18.8 kcal (28.9 +/- 13.5%) during cycle ergometry, 28.2 +/- 20.3 kcal (17.7 +/- 11.8%) during stepping exercise, and overestimated total energy expenditure by 21.7 +/- 8.7 kcal (29.3 +/- 13.8%) during arm ergometer exercise (P < or = 0.001). At the request of the investigators, exercise-specific algorithms were developed by the manufacturer and applied to the data that resulted in nonsignificant differences in total energy expenditure between indirect calorimetry and the SenseWear Pro Armband of 4.6 +/- 18.1 kcal (2.8 +/- 9.4%), 0.3 +/- 11.3 kcal (0.9 +/- 10.7%), 2.5 +/- 18.3 kcal (0.9 +/- 11.9%), and 3.2 +/- 8.1 kcal (3.8 +/- 9.9%) for the walk, cycle ergometer, step, and arm ergometer exercises, respectively. CONCLUSIONS: It appears that it is necessary to apply exercise-specific algorithms to the SenseWear Pro Armband to enhance the accuracy of estimating energy expenditure during periods of exercise. When exercise-specific algorithms are used, the SenseWear Pro Armband provides an accurate estimate of energy expenditure when compared to indirect calorimetry during exercise periods examined in this study.

Overview

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1249/01.mss.0000126805.32659.43

Cites

1 of 1 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 1 references

Cited by

See all 362

Metadata

Authors
JAKICIC, J. M., MARCUS, M., GALLAGHER, K. I., RANDALL, C., THOMAS, E., GOSS, F. L., & ROBERTSON, R. J.
Venue
Medicine & Science in Sports & Exercise
Published
2004-05
Volume
36
Issue
5
Pages
897-904
ISSN
0195-9131 (ISSN-L)
OpenAlex
W2078569103
Cited by
362
References
1
FWCI
6.65
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Evaluation of the SenseWear Pro Armband™ to Assess Energy Expenditure during Exercise. https://app.cochat.ai/papers/10.1249/01.mss.0000126805.32659.43
The paper
JAKICIC, J. M., MARCUS, M., GALLAGHER, K. I., RANDALL, C., THOMAS, E., GOSS, F. L., & ROBERTSON, R. J. (2004). Evaluation of the SenseWear Pro Armband™ to Assess Energy Expenditure during Exercise. Medicine & Science in Sports & Exercise. https://doi.org/10.1249/01.mss.0000126805.32659.43

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.