Evaluation of the SenseWear Pro Armband™ to Assess Energy Expenditure during Exercise
The DOI matches its Crossref record; 11 of the 11 references it cites were found in a registry or an index.
Abstract
PURPOSE: To assess the accuracy of the SenseWear Pro Armband for estimating energy expenditure during exercise. METHODS: : Forty subjects (age = 23.2 +/- 3.8 yr; body mass index = 23.8 +/- 3.1 kg x m) performed four exercises (walking, cycling, stepping, arm ergometry) with each exercise lasting 20-30 min and workload increasing at 10-min intervals. Subjects wore the SenseWear Pro Armband on the right arm, and energy expenditure was estimated using proprietary equations developed by the manufacturer. Estimated energy expenditure from the SenseWear Pro Armband was compared with energy expenditure determined from indirect open-circuit calorimetry, which served as the criterion measure. RESULTS: : When a generalized proprietary algorithm was applied to the data, the SenseWear Pro Armband significantly underestimated total energy expenditure by 14.9 +/- 17.5 kcal (6.9 +/- 8.5%) during walking exercise, 32.4 +/- 18.8 kcal (28.9 +/- 13.5%) during cycle ergometry, 28.2 +/- 20.3 kcal (17.7 +/- 11.8%) during stepping exercise, and overestimated total energy expenditure by 21.7 +/- 8.7 kcal (29.3 +/- 13.8%) during arm ergometer exercise (P < or = 0.001). At the request of the investigators, exercise-specific algorithms were developed by the manufacturer and applied to the data that resulted in nonsignificant differences in total energy expenditure between indirect calorimetry and the SenseWear Pro Armband of 4.6 +/- 18.1 kcal (2.8 +/- 9.4%), 0.3 +/- 11.3 kcal (0.9 +/- 10.7%), 2.5 +/- 18.3 kcal (0.9 +/- 11.9%), and 3.2 +/- 8.1 kcal (3.8 +/- 9.9%) for the walk, cycle ergometer, step, and arm ergometer exercises, respectively. CONCLUSIONS: It appears that it is necessary to apply exercise-specific algorithms to the SenseWear Pro Armband to enhance the accuracy of estimating energy expenditure during periods of exercise. When exercise-specific algorithms are used, the SenseWear Pro Armband provides an accurate estimate of energy expenditure when compared to indirect calorimetry during exercise periods examined in this study.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Measurement in Medicine: The Analysis of Method Comparison Studies
Altman, D. G., & Bland, J. M. (1983) · The Statistician · doi:10.2307/2987937 · Cited by 4,300
Accuracy of five electronic pedometers for measuring distance walked
BASSETT, D. R., AINSWORTH, B. E., LEGGETT, S. R., MATHIEN, C. A., MAIN, J. A., HUNTER, D. C., & DUNCAN, G. E. (1996) · Medicine & Science in Sports & Exercise · doi:10.1097/00005768-199608000-00019 · Cited by 552
Jakicic, J. M., Winters, C., Lang, W., & Wing, R. R. (1999) · JAMA · doi:10.1001/jama.282.16.1554 · Cited by 536
Self-citationThe utility of the Digi-Walker step counter to assess daily physical activity patterns
WELK, G. J., DIFFERDING, J. A., THOMPSON, R. W., BLAIR, S. N., DZIURA, J., & HART, P. (2000) · Medicine & Science in Sports & Exercise · doi:10.1097/00005768-200009001-00007 · Cited by 293
Recent Advances from Application of Doubly Labeled Water to Measurement of Human Energy Expenditure
Schoeller, D. A. (1999) · The Journal of Nutrition · doi:10.1093/jn/129.10.1765 · Cited by 236
Physical Activity and Long‐Term Maintenance of Weight Loss
Pronk, N. P., & Wing, R. R. (1994) · Obesity Research · doi:10.1002/j.1550-8528.1994.tb00110.x · Cited by 206
The accuracy of the TriTrac-R3D accelerometer to estimate energy expenditure
JAKICIC, J. M., WINTERS, C., LAGALLY, K., HO, J., ROBERTSON, R. J., & WING, R. R. (1999) · Medicine & Science in Sports & Exercise · doi:10.1097/00005768-199905000-00020 · Cited by 149
Self-citationRelationship of physical activity to eating behaviors and weight loss in women
JAKICIC, J. M., WING, R. R., & WINTERS-HART, C. (2002) · Medicine & Science in Sports & Exercise · doi:10.1097/00005768-200210000-00018 · Cited by 126
Self-citationA critical evaluation of heart rate monitoring to assess energy expenditure in individuals
Li, R., Deurenberg, P., & Hautvast, J. (1993) · American Journal of Clinical Nutrition · doi:10.1093/ajcn/58.5.602 · Cited by 112
Accuracy of self-reported exercise and the relationship with weight loss in overweight women
JAKICIC, J. M., POLLEY, B. A., & WING, R. R. (1998) · Medicine & Science in Sports & Exercise · doi:10.1097/00005768-199804000-00024 · Cited by 102
Self-citation
Cited by
Strath, S. J., Kaminsky, L. A., Ainsworth, B. E., Ekelund, U., Freedson, P. S., Gary, R. A., Richardson, C. R., Smith, D. T., & Swartz, A. M. (2013) · Circulation · doi:10.1161/01.cir.0000435708.67487.da · Cited by 1,029
The Technology of Accelerometry-Based Activity Monitors: Current and Future
CHEN, K. Y., & BASSETT, D. R. (2005) · Medicine & Science in Sports & Exercise · doi:10.1249/01.mss.0000185571.49104.82 · Cited by 996
Calibration of Accelerometer Output for Adults
MATTHEW, C. E. (2005) · Medicine & Science in Sports & Exercise · doi:10.1249/01.mss.0000185659.11982.3d · Cited by 659
Practical Guide to Measuring Physical Activity
Sylvia, L. G., Bernstein, E. E., Hubbard, J. L., Keating, L., & Anderson, E. J. (2014) · Journal of the Academy of Nutrition and Dietetics · doi:10.1016/j.jand.2013.09.018 · Cited by 637
Jakicic, J. M., Davis, K. K., Rogers, R. J., King, W. C., Marcus, M. D., Helsel, D., Rickman, A. D., Wahed, A. S., & Belle, S. H. (2016) · JAMA · doi:10.1001/jama.2016.12858 · Cited by 621
Self-citationAssessment of physical activity in youth
Corder, K., Ekelund, U., Steele, R. M., Wareham, N. J., & Brage, S. (2008) · Journal of Applied Physiology · doi:10.1152/japplphysiol.00094.2008 · Cited by 581
Quantifying physical activity in daily life with questionnaires and motion sensors in COPD
Pitta, F., Troosters, T., Probst, V. S., Spruit, M. A., Decramer, M., & Gosselink, R. (2006) · European Respiratory Journal · doi:10.1183/09031936.06.00064105 · Cited by 473
Accuracy of Armband Monitors for Measuring Daily Energy Expenditure in Healthy Adults
JOHANNSEN, D. L., CALABRO, M. A., STEWART, J., FRANKE, W., ROOD, J. C., & WELK, G. J. (2010) · Medicine & Science in Sports & Exercise · doi:10.1249/mss.0b013e3181e0b3ff · Cited by 424
Dowd, K. P., Szeklicki, R., Minetto, M. A., Murphy, M. H., Polito, A., Ghigo, E., van der Ploeg, H., Ekelund, U., Maciaszek, J., Stemplewski, R., et al. (2018) · International Journal of Behavioral Nutrition and Physical Activity · doi:10.1186/s12966-017-0636-2 · Cited by 385
“1%)) [282, 328, 341, 358, 367, 369, 370, 375, 376, 380, 382, 383, 385, 387]; (METs over specified durations; Additional file 1: figure S3g (-67.”
BackgroundMurphy, S. L. (2009) · Preventive Medicine · doi:10.1016/j.ypmed.2008.12.001 · Cited by 326
Validity of activity monitors in health and chronic disease: a systematic review
Van Remoortel, H., Giavedoni, S., Raste, Y., Burtin, C., Louvaris, Z., Gimeno-Santos, E., Langer, D., Glendenning, A., Hopkinson, N. S., Vogiatzis, I., et al. (2012) · International Journal of Behavioral Nutrition and Physical Activity · doi:10.1186/1479-5868-9-84 · Cited by 277
Field Validation of the MTI Actigraph and BodyMedia Armband Monitor Using the IDEEA Monitor
Welk, G. J., McClain, J. J., Eisenmann, J. C., & Wickel, E. E. (2007) · Obesity · doi:10.1038/oby.2007.624 · Cited by 244
“Proprietary algorithms that take into account gender, age, height, and weight are then used to estimate EE (13).”
BackgroundMethodShuger, S. L., Barry, V. W., Sui, X., McClain, A., Hand, G. A., Wilcox, S., Meriwether, R. A., Hardin, J. W., & Blair, S. N. (2011) · International Journal of Behavioral Nutrition and Physical Activity · doi:10.1186/1479-5868-8-41 · Cited by 198
“, physical activity and exercise) [15-20].”
O’Driscoll, R., Turicchi, J., Beaulieu, K., Scott, S., Matu, J., Deighton, K., Finlayson, G., & Stubbs, J. (2020) · British Journal of Sports Medicine · doi:10.1136/bjsports-2018-099643 · Cited by 188
Energy expenditure: components and evaluation methods.
Volp, A. C. P., de Oliveira, F. C. E., Alves, R. D. M., Esteves, E. A., & Bressan, J. (2012) · PubMed · doi:10.1590/s0212-16112011000300002 · Cited by 167
Activity Monitoring and Energy Expenditure in COPD Patients: A Validation Study
Patel, S. A., Benzo, R. P., Slivka, W. A., & Sciurba, F. C. (2007) · COPD: Journal of Chronic Obstructive Pulmonary Disease · doi:10.1080/15412550701246658 · Cited by 144
Soundy, A., Roskell, C., Stubbs, B., & Vancampfort, D. (2014) · Archives of Psychiatric Nursing · doi:10.1016/j.apnu.2013.12.002 · Cited by 131
Arribat, Y., Broskey, N. T., Greggio, C., Boutant, M., Conde Alonso, S., Kulkarni, S. S., Lagarrigue, S., Carnero, E. A., Besson, C., Cantó, C., et al. (2019) · Acta Physiologica · doi:10.1111/apha.13179 · Cited by 112
Methodology for Using Long-Term Accelerometry Monitoring to Describe Daily Activity Patterns in COPD
Hecht, A., Ma, S., Porszasz, J., Casaburi, R., & Netw, F. T. C. C. R. (2009) · COPD: Journal of Chronic Obstructive Pulmonary Disease · doi:10.1080/15412550902755044 · Cited by 91
Furlanetto, K. C., Bisca, G. W., Oldemberg, N., Sant'Anna, T. J., Morakami, F. K., Camillo, C. A., Cavalheri, V., Hernandes, N. A., Probst, V. S., Ramos, E. M., et al. (2010) · Archives of Physical Medicine and Rehabilitation · doi:10.1016/j.apmr.2009.10.024 · Cited by 87
Protective effect of aerobic physical activity on sleep behavior in breast cancer survivors
Roveda, E., Vitale, J. A., Bruno, E., Montaruli, A., Pasanisi, P., Villarini, A., Gargano, G., Galasso, L., Berrino, F., Caumo, A., et al. (2017) · Integrative Cancer Therapies · doi:10.1177/1534735416651719 · Cited by 78
“The SenseWear Pro 3 Armband (Body-Media, Pittsburgh, USA) was used to collect data on energy expenditure (EE) and motion level.(35-37) All women wore the device for 1 week on the right upper arm over the triceps muscle.”
MethodDeLany, J. P., Kelley, D. E., Hames, K. C., Jakicic, J. M., & Goodpaster, B. H. (2014) · Obesity · doi:10.1002/oby.20525 · Cited by 60
Self-citationTierney, M., Fraser, A., Purtill, H., & Kennedy, N. (2013) · Arthritis Care & Research · doi:10.1002/acr.21914 · Cited by 56
Applying a technology‐based system for weight loss in adults with obesity
Rogers, R. J., Lang, W., Barone Gibbs, B., Davis, K. K., Burke, L. E., Kovacs, S. J., Portzer, L. A., & Jakicic, J. M. (2016) · Obesity Science & Practice · doi:10.1002/osp4.18 · Cited by 40
Self-citationThe Impact of Different Degrees of Feedback on Physical Activity Levels: A 4-Week Intervention Study
Van Hoye, K., Boen, F., & Lefevre, J. (2015) · International Journal of Environmental Research and Public Health · doi:10.3390/ijerph120606561 · Cited by 30
“PA outcome variables were measured by means of the SWA, a multi-sensor activity monitor which has previously been shown to accurately estimate EE during light to moderate intensity activities [30,31].”
Method
Metadata
- Authors
- JAKICIC, J. M., MARCUS, M., GALLAGHER, K. I., RANDALL, C., THOMAS, E., GOSS, F. L., & ROBERTSON, R. J.
- Venue
- Medicine & Science in Sports & Exercise
- Published
- 2004-05
- Volume
- 36
- Issue
- 5
- Pages
- 897-904
- ISSN
- 0195-9131 (ISSN-L)
- OpenAlex
- W2078569103
- Cited by
- 362
- References
- 11
- FWCI
- 6.65
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.