CoChat

Immune Response to a 30-Minute Walk

NIEMAN, DAVID C., HENSON, DRU A., AUSTIN, MELANIE D., BROWN, VICTOR A. · 2005 · Medicine & Science in Sports & Exercise
Cited by 143

The DOI matches its Crossref record; 1 of the 1 references it cites were found in a registry or an index.

Abstract

PURPOSE: To measure several components of immune changes related to walking 30 min with or without an exercise assist device compared with sitting. METHODS: Fifteen healthy and nonobese female subjects (37.5 +/- 3.1 yr of age) accustomed to regular walking were recruited and tested for aerobic power (VO(2max) 34.4 +/- 1.4 mL.kg(-1).min(-1)). During three randomly assigned 30-min test sessions, subjects functioned as their own controls and either sat in the laboratory, walked at approximately 60% VO(2max), or walked at the same treadmill speed using the BODY BAT Aerobic Exerciser. This exercise assist device resembles a pair of baseball bats seamlessly joined together and is held with both hands and swung to shoulder height across the body in a natural side to side pendulum motion. Saliva and blood samples were collected pre- and postexercise, and 1 h postexercise, with the data statistically analyzed using a 3 x 3 repeated measures ANOVA. RESULTS: Walking with the exercise assist device increased oxygen consumption 11 +/- 2% and heart rate 8 +/- 2 beats.min(-1). The pattern of increase in blood counts for neutrophils, lymphocytes, monocytes, and natural killer cells, plasma interleukin-6 concentration, and PHA-induced lymphocyte proliferation differed significantly when comparing walking with sitting, but no differences were found between walking with or without the exercise assist device. No significant increases over time or interaction effects were measured for plasma cortisol concentration, salivary IgA output, or plasma interleukin-1 receptor antagonist concentration. CONCLUSIONS: The use of an exercise assist device increased oxygen consumption 11% during walking, but did not alter the pattern of change in several components of immunity measured during walking alone in comparison to sitting. Walking caused modest and short-lived changes in immune parameters, most notably for neutrophil and natural killer blood cell counts.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1249/01.mss.0000149808.38194.21

Cites

1 of 1 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 1 references

Cited by

See all 143

Metadata

Authors
NIEMAN, D. C., HENSON, D. A., AUSTIN, M. D., & BROWN, V. A.
Venue
Medicine & Science in Sports & Exercise
Published
2005-01
Volume
37
Issue
1
Pages
57-62
ISSN
0195-9131 (ISSN-L)
OpenAlex
W2071463384
Cited by
143
References
1
FWCI
6.54
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Immune Response to a 30-Minute Walk. https://app.cochat.ai/papers/10.1249/01.mss.0000149808.38194.21
The paper
NIEMAN, D. C., HENSON, D. A., AUSTIN, M. D., & BROWN, V. A. (2005). Immune Response to a 30-Minute Walk. Medicine & Science in Sports & Exercise. https://doi.org/10.1249/01.mss.0000149808.38194.21

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.