Elastography for Muscle Biomechanics: Toward the Estimation of Individual Muscle Force
Abstract
In Brief Estimation of individual muscle force remains one of the main challenges in biomechanics. This review presents a series of experiments that used ultrasound shear wave elastography to support the hypothesis that muscle stiffness is linearly related to both active and passive muscle forces. Examples of studies that used measurement of muscle stiffness to estimate changes in muscle force are presented. Stiffness measured using shear wave elastography can be used to estimate change in muscle force during isometric contractions, therefore providing new insights in muscle biomechanics.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Supersonic shear imaging: a new technique for soft tissue elasticity mapping
Bercoff, J., Tanter, M., & Fink, M. (2004) · IEEE Transactions on Ultrasonics, Ferroelectrics and Frequency Control · doi:10.1109/tuffc.2004.1295425 · Cited by 2,476
Self-citationMoving differently in pain: A new theory to explain the adaptation to pain
Hodges, P. W., & Tucker, K. (2011) · Pain · doi:10.1016/j.pain.2010.10.020 · Cited by 1,269
Self-citationUltrasound elastography: Principles and techniques
Gennisson, J.-L., Deffieux, T., Fink, M., & Tanter, M. (2013) · Diagnostic and Interventional Imaging · doi:10.1016/j.diii.2013.01.022 · Cited by 1,052
Self-citationBuchanan, T. S., Lloyd, D. G., Manal, K., & Besier, T. F. (2004) · Journal of Applied Biomechanics · doi:10.1123/jab.20.4.367 · Cited by 941
Model-based estimation of muscle forces exerted during movements
Erdemir, A., McLean, S., Herzog, W., & van den Bogert, A. J. (2007) · Clinical Biomechanics · doi:10.1016/j.clinbiomech.2006.09.005 · Cited by 872
Predictability of skeletal muscle tension from architectural determinations in guinea pig hindlimbs
Powell, P. L., Roy, R. R., Kanim, P., Bello, M. A., & Edgerton, V. R. (1984) · Journal of Applied Physiology · doi:10.1152/jappl.1984.57.6.1715 · Cited by 555
Validation of shear wave elastography in skeletal muscle
Eby, S. F., Song, P., Chen, S., Chen, Q., Greenleaf, J. F., & An, K.-N. (2013) · Journal of Biomechanics · doi:10.1016/j.jbiomech.2013.07.033 · Cited by 545
The relation between stiffness and filament overlap in stimulated frog muscle fibres.
Ford, L. E., Huxley, A. F., & Simmons, R. M. (1981) · The Journal of Physiology · doi:10.1113/jphysiol.1981.sp013582 · Cited by 483
Myoelectric signal versus force relationship in different human muscles
Lawrence, J. H., & De Luca, C. J. (1983) · Journal of Applied Physiology · doi:10.1152/jappl.1983.54.6.1653 · Cited by 453
3D ultrafast ultrasound imaging in vivo
Provost, J., Papadacci, C., Arango, J. E., Imbault, M., Fink, M., Gennisson, J.-L., Tanter, M., & Pernot, M. (2014) · Physics in Medicine and Biology · doi:10.1088/0031-9155/59/19/l1 · Cited by 356
Self-citationUltrasound Elastography: The New Frontier in Direct Measurement of Muscle Stiffness
Brandenburg, J. E., Eby, S. F., Song, P., Zhao, H., Brault, J. S., Chen, S., & An, K.-N. (2014) · Archives of Physical Medicine and Rehabilitation · doi:10.1016/j.apmr.2014.07.007 · Cited by 327
The relation between force and integrated electrical activity in fatigued muscle
Edwards, R. G., & Lippold, O. C. J. (1956) · The Journal of Physiology · doi:10.1113/jphysiol.1956.sp005558 · Cited by 324
Magnetic resonance elastography of skeletal muscle
Dresner, M. A., Rose, G. H., Rossman, P. J., Muthupillai, R., Manduca, A., & Ehman, R. L. (2001) · Journal of Magnetic Resonance Imaging · doi:10.1002/1522-2586(200102)13:2<269::aid-jmri1039>3.0.co;2-1 · Cited by 307
Maïsetti, O., Hug, F., Bouillard, K., & Nordez, A. (2012) · Journal of Biomechanics · doi:10.1016/j.jbiomech.2012.01.009 · Cited by 263
Self-citationSupersonic shear imaging provides a reliable measurement of resting muscle shear elastic modulus
Lacourpaille, L., Hug, F., Bouillard, K., Hogrel, J.-Y., & Nordez, A. (2012) · Physiological Measurement · doi:10.1088/0967-3334/33/3/n19 · Cited by 237
Self-citationSonoelastography: Musculoskeletal Applications
Klauser, A. S., Miyamoto, H., Bellmann-Weiler, R., Feuchtner, G. M., Wick, M. C., & Jaschke, W. R. (2014) · Radiology · doi:10.1148/radiol.14121765 · Cited by 211
Relationship between shear elastic modulus and passive muscle force: An ex-vivo study
Koo, T. K., Guo, J.-Y., Cohen, J. H., & Parker, K. J. (2013) · Journal of Biomechanics · doi:10.1016/j.jbiomech.2013.05.016 · Cited by 197
Yoshitake, Y., Takai, Y., Kanehisa, H., & Shinohara, M. (2014) · Muscle & Nerve · doi:10.1002/mus.24104 · Cited by 196
Couade, M., Pernot, M., Messas, E., Bel, A., Ba, M., Hagege, A., Fink, M., & Tanter, M. (2011) · IEEE Transactions on Medical Imaging · doi:10.1109/tmi.2010.2076829 · Cited by 190
Self-citationBrum, J., Bernal, M., Gennisson, J. L., & Tanter, M. (2014) · Physics in Medicine and Biology · doi:10.1088/0031-9155/59/3/505 · Cited by 190
Self-citationEstimation of Individual Muscle Force Using Elastography
Bouillard, K., Nordez, A., & Hug, F. (2011) · PLoS ONE · doi:10.1371/journal.pone.0029261 · Cited by 187
Self-citationKoo, T. K. K., Guo, J., Cohen, J. H., & Parker, K. J. (2013) · Clinical Biomechanics · doi:10.1016/j.clinbiomech.2013.11.009 · Cited by 157
Ateş, F., Hug, F., Bouillard, K., Jubeau, M., Frappart, T., Couade, M., Bercoff, J., & Nordez, A. (2015) · Journal of Electromyography and Kinesiology · doi:10.1016/j.jelekin.2015.02.005 · Cited by 155
Self-citationLacourpaille, L., Nordez, A., Hug, F., Couturier, A., Dibie, C., & Guilhem, G. (2014) · Acta Physiologica · doi:10.1111/apha.12272 · Cited by 155
Self-citationNon‐invasive assessment of muscle stiffness in patients with duchenne muscular dystrophy
Lacourpaille, L., Hug, F., Guével, A., Péréon, Y., Magot, A., Hogrel, J., & Nordez, A. (2014) · Muscle & Nerve · doi:10.1002/mus.24445 · Cited by 139
Self-citationUltrasound Elastography – Review of Techniques and its Clinical Applications
Zaleska–Dorobisz, U., Kaczorowski, K., Pawluś, A., Puchalska, A., & Inglot, M. (2014) · Advances in Clinical and Experimental Medicine · doi:10.17219/acem/26301 · Cited by 121
Massage induces an immediate, albeit short‐term, reduction in muscle stiffness
Crommert, M. E., Lacourpaille, L., Heales, L., Tucker, K. J., & Hug, F. (2014) · Scandinavian Journal of Medicine and Science in Sports · doi:10.1111/sms.12341 · Cited by 111
Self-citationBouillard, K., Hug, F., Guével, A., & Nordez, A. (2012) · Journal of Applied Physiology · doi:10.1152/japplphysiol.00858.2012 · Cited by 108
Self-citationA new method for measuring passive length–tension properties of human gastrocnemius muscle in vivo
Hoang, P. D., Gorman, R. B., Todd, G., Gandevia, S. C., & Herbert, R. (2004) · Journal of Biomechanics · doi:10.1016/j.jbiomech.2004.05.046 · Cited by 105
Bouillard, K., Jubeau, M., Nordez, A., & Hug, F. (2013) · Journal of Neurophysiology · doi:10.1152/jn.00595.2013 · Cited by 97
Self-citationComb-Push Ultrasound Shear Elastography (CUSE) With Various Ultrasound Push Beams
Song, P., Urban, M. W., Manduca, A., Zhao, H., Greenleaf, J. F., & Chen, S. (2013) · IEEE Transactions on Medical Imaging · doi:10.1109/tmi.2013.2257831 · Cited by 94
Influence of Passive Muscle Tension on Electromechanical Delay in Humans
Lacourpaille, L., Hug, F., & Nordez, A. (2013) · PLoS ONE · doi:10.1371/journal.pone.0053159 · Cited by 75
Self-citationLength-force characteristics of in vivo human muscle reflected by supersonic shear imaging
Sasaki, K., Toyama, S., & Ishii, N. (2014) · Journal of Applied Physiology · doi:10.1152/japplphysiol.01058.2013 · Cited by 64
Cited by
Application of ultrasound for muscle assessment in sarcopenia: 2020 SARCUS update
Perkisas, S., Bastijns, S., Baudry, S., Bauer, J., Beaudart, C., Beckwée, D., Cruz-Jentoft, A., Gasowski, J., Hobbelen, H., Jager-Wittenaar, H., et al. (2021) · European Geriatric Medicine · doi:10.1007/s41999-020-00433-9 · Cited by 329
Cunningham, R. J., & Loram, I. D. (2020) · Journal of The Royal Society Interface · doi:10.1098/rsif.2019.0715 · Cited by 36
“SWE has a maximum sampling rate of 1 Hz [14].”
BackgroundMethodInfluential
Metadata
- Authors
- Hug, F., Tucker, K., Gennisson, J.-L., Tanter, M., & Nordez, A.
- Venue
- Exercise and Sport Sciences Reviews
- Published
- 2015-07
- Volume
- 43
- Issue
- 3
- Pages
- 125-133
- ISSN
- 0091-6331 (ISSN-L)
- OpenAlex
- W2085190694
- Cited by
- 342
- References
- 33
- FWCI
- 17.24
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.