CoChat

The Respiratory Compensation Point is Not a Valid Surrogate for Critical Power

LEO, JEFFREY A., SABAPATHY, SURENDRAN, SIMMONDS, MICHAEL J., CROSS, TROY J. · 2017 · Medicine & Science in Sports & Exercise
Cited by 47

The DOI matches its Crossref record; 1 of the 1 references it cites were found in a registry or an index.

Abstract

PURPOSE: It is unclear whether the respiratory compensation point (RCP) may be used as a valid surrogate for critical power (CP). Accordingly, we sought to determine the measurement agreement between the CP and the RCP obtained during incremental cycling of varying ramp slopes. METHODS: Eleven recreationally active men completed three separate ramp-incremental cycling protocols, where the work rate increment was slow (SR, 15 W·min), medium (MR, 30 W·min), or fast (FR, 45 W·min). The RCP was obtained using the ventilatory equivalent for CO2 output method. The CP was determined via Morton's model for ramp-incremental exercise. The assumption that the RCP and the CP occur at equivalent external work rates was assessed by one-way repeated-measures ANOVA and by evaluating the concordance correlation coefficient (CCC) and typical error (root-mean-square error [RMSE]) for each ramp protocol, separately. RESULTS: The external work rate corresponding to the RCP increased with increases in the ramp-incremental slope (P < 0.05). The RCP values in MR (268 ± 37 W) and FR (292 ± 41 W), but not SR (243 ± 35 W), were different (P < 0.05) from CP (247 ± 43 W). The degree to which the relationship between the CP and the RCP approximated the line of identity was relatively poor for SR (CCC = 0.73 and RMSE = 28 W), MR (CCC = 0.63 and RMSE = 36 W), and FR (CCC = 0.42 and RMSE = 55 W). CONCLUSIONS: Our data confirm that the external work rate associated with the RCP is labile and that these power outputs display poor measurement agreement with the CP. Taken together, these findings indicate that the RCP does not provide an accurate estimation of CP.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1249/mss.0000000000001226

Cites

1 of 1 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 1 references

Cited by

See all 47

Metadata

Authors
LEO, J. A., SABAPATHY, S., SIMMONDS, M. J., & CROSS, T. J.
Venue
Medicine & Science in Sports & Exercise
Published
2017-07
Volume
49
Issue
7
Pages
1452-1460
ISSN
0195-9131 (ISSN-L)
OpenAlex
W2588564599
Cited by
47
References
1
FWCI
7.23
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: The Respiratory Compensation Point is Not a Valid Surrogate for Critical Power. https://app.cochat.ai/papers/10.1249/mss.0000000000001226
The paper
LEO, J. A., SABAPATHY, S., SIMMONDS, M. J., & CROSS, T. J. (2017). The Respiratory Compensation Point is Not a Valid Surrogate for Critical Power. Medicine & Science in Sports & Exercise. https://doi.org/10.1249/mss.0000000000001226

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.