The Respiratory Compensation Point and the Deoxygenation Break Point Are Valid Surrogates for Critical Power and Maximum Lactate Steady State
The DOI matches its Crossref record; 13 of the 13 references it cites were found in a registry or an index.
Abstract
For any type of endurance exercise, there exists a range of task-specific intensities (e.g., speed or power output) that can be sustained in steady-state conditions by oxidative metabolism without a progressive depletion of high-energy phosphates or continuous lactate accumulation. The task-specific intensity at the ceiling of this range identifies a metabolic rate above which oxidative phosphorylation must be further supported at the substrate level for exercise to continue, leading to non–steady-state conditions, accumulation of muscle metabolites, acidification of the tissue, and a hastening of exhaustion. This “critical metabolic rate” that defines sustainable from unsustainable exercise often is identified by measuring critical power (CP) or the maximal lactate steady-state (MLSS). We suggest also that the respiratory compensation point (RCP) and the near infrared spectroscopy-derived muscle deoxygenation break point (deoxy-BP) of ramp-incremental exercise reflect this important boundary. Our group showed that the oxygen uptakes (V˙O2) associated with CP, MLSS, RCP, and deoxy-BP were not different in a single cohort of healthy volunteers (1). Although this is the only study to compare simultaneously all of these variables, other comparative studies have corroborated V˙O2 as a common denominator among these indices (2,3), supporting the idea that all represent different physiological expressions of the same underlying phenomenon. Still, others have denied the equivalence…
Overview
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
In the citing paper
“Multiple studies have validated various stationary NIRS sensors with each of the physiological and performance markers outlined above, during various modes of exercise (12, 17, 22, 29–31).”
From Comparing the reliability of muscle oxygen saturation with common performance and physiological markers across cycling exercise intensity (2023) · cites this paper as [12]
Citations
Cites
Critical Power: An Important Fatigue Threshold in Exercise Physiology
POOLE, D. C., BURNLEY, M., VANHATALO, A., ROSSITER, H. B., & JONES, A. M. (2016) · Medicine & Science in Sports & Exercise · doi:10.1249/mss.0000000000000939 · Cited by 535
Exercise Intensity Thresholds: Identifying the Boundaries of Sustainable Performance
KEIR, D. A., FONTANA, F. Y., ROBERTSON, T. C., MURIAS, J. M., PATERSON, D. H., KOWALCHUK, J. M., & POGLIAGHI, S. (2015) · Medicine & Science in Sports & Exercise · doi:10.1249/mss.0000000000000613 · Cited by 205
Self-citationMeyer, T., Faude, O., Scharhag, J., Urhausen, A., & Kindermann, W. (2004) · British Journal of Sports Medicine · doi:10.1136/bjsm.2003.007815 · Cited by 114
Using ramp-incremental V̇O2 responses for constant-intensity exercise selection
Keir, D. A., Paterson, D. H., Kowalchuk, J. M., & Murias, J. M. (2018) · Applied Physiology, Nutrition, and Metabolism · doi:10.1139/apnm-2017-0826 · Cited by 97
Self-citationCritical power: How different protocols and models affect its determination
Mattioni Maturana, F., Fontana, F. Y., Pogliaghi, S., Passfield, L., & Murias, J. M. (2018) · Journal of Science and Medicine in Sport · doi:10.1016/j.jsams.2017.11.015 · Cited by 93
Self-citationCan measures of critical power precisely estimate the maximal metabolic steady-state?
Mattioni Maturana, F., Keir, D. A., McLay, K. M., & Murias, J. M. (2016) · Applied Physiology, Nutrition, and Metabolism · doi:10.1139/apnm-2016-0248 · Cited by 69
Self-citationDetermination of Maximal Lactate Steady State in Healthy Adults: Can NIRS Help?
BELLOTTI, C., CALABRIA, E., CAPELLI, C., & POGLIAGHI, S. (2013) · Medicine & Science in Sports & Exercise · doi:10.1249/mss.0b013e3182828ab2 · Cited by 65
Self-citationKeir, D. A., Benson, A. P., Love, L. K., Robertson, T. C., Rossiter, H. B., & Kowalchuk, J. M. (2016) · Journal of Applied Physiology · doi:10.1152/japplphysiol.00804.2015 · Cited by 49
Self-citationThe Respiratory Compensation Point is Not a Valid Surrogate for Critical Power
LEO, J. A., SABAPATHY, S., SIMMONDS, M. J., & CROSS, T. J. (2017) · Medicine & Science in Sports & Exercise · doi:10.1249/mss.0000000000001226 · Cited by 47
Exercise Thresholds on Trial: Are They Really Equivalent?
CAEN, K., VERMEIRE, K., BOURGOIS, J. G., & BOONE, J. (2018) · Medicine & Science in Sports & Exercise · doi:10.1249/mss.0000000000001547 · Cited by 42
Cited by
An Examination and Critique of Current Methods to Determine Exercise Intensity
Jamnick, N. A., Pettitt, R. W., Granata, C., Pyne, D. B., & Bishop, D. J. (2020) · Sports Medicine · doi:10.1007/s40279-020-01322-8 · Cited by 424
The anaerobic threshold: 50+ years of controversy
Poole, D. C., Rossiter, H. B., Brooks, G. A., & Gladden, L. B. (2021) · The Journal of Physiology · doi:10.1113/jp279963 · Cited by 312
Identification of Non-Invasive Exercise Thresholds: Methods, Strategies, and an Online App
Keir, D. A., Iannetta, D., Mattioni Maturana, F., Kowalchuk, J. M., & Murias, J. M. (2022) · Sports Medicine · doi:10.1007/s40279-021-01581-z · Cited by 193
Self-citationGalán‐Rioja, M. Á., González‐Mohíno, F., Poole, D. C., & González‐Ravé, J. M. (2020) · Sports Medicine · doi:10.1007/s40279-020-01314-8 · Cited by 144
Iannetta, D., de Almeida Azevedo, R., Keir, D. A., & Murias, J. M. (2019) · Journal of Applied Physiology · doi:10.1152/japplphysiol.00508.2019 · Cited by 109
Self-citation
Metadata
- Authors
- KEIR, D. A., POGLIAGHI, S., & MURIAS, J. M.
- Affiliations
- University Health Network (CA)
- University of Verona (IT)
- University of Calgary (CA)
- Venue
- Medicine & Science in Sports & Exercise
- Published
- 2018-11
- Volume
- 50
- Issue
- 11
- Pages
- 2375-2378
- ISSN
- 0195-9131 (ISSN-L)
- 1530-0315
- OpenAlex
- W2888031567
- Cited by
- 65
- References
- 13
- Citations by year
- 2026: 3 · 2025: 10 · 2024: 8 · 2023: 9 · 2022: 8 · 2021: 7 · 2020: 11 · 2019: 8 · 2018: 1
- FWCI
- 9.27
- Type
- journal article
- Language
- en
- Open access
- closed
- Locations
- Medicine & Science in Sports & Exercise (publishedVersion)
- PubMed (publishedVersion)
- Topics
- Health Sciences › Medicine › Physiology (medical) › Cardiovascular and exercise physiology
- Health Sciences › Medicine › Orthopedics and Sports Medicine › Sports Performance and Training
- Health Sciences › Nursing › Nutrition and Dietetics › Muscle metabolism and nutrition
- Keywords
- respiratory compensation point, critical power, maximal lactate steady state, oxygen consumption, near-infrared spectroscopy, muscle oxygenation, endurance exercise, high-energy phosphates, substrate-level phosphorylation, exercise exhaustion
- MeSH terms
- Energy Metabolism, Hemoglobins, Humans, Myoglobin, Oxygen Consumption, Anaerobic Threshold, Respiratory Mechanics, Muscle, Skeletal, Lactic Acid
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: The Respiratory Compensation Point and the Deoxygenation Break Point Are Valid Surrogates for Critical Power and Maximum Lactate Steady State. https://app.cochat.ai/papers/10.1249/mss.0000000000001698
- The paper
- KEIR, D. A., POGLIAGHI, S., & MURIAS, J. M. (2018). The Respiratory Compensation Point and the Deoxygenation Break Point Are Valid Surrogates for Critical Power and Maximum Lactate Steady State. Medicine & Science in Sports & Exercise. https://doi.org/10.1249/mss.0000000000001698
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.