PURPOSE: The aim of this study was to assess the accuracy of temporal scanning thermometry in monitoring internal temperature increases during passive heating. METHODS: Sixteen subjects (5 males and 11 females) underwent a whole-body passive heat stress (water-perfused suit) to increase internal temperature. Temperatures were obtained with a temporal scanner and with an ingestible-pill telemetry system that tracks intestinal temperature. Temperatures were recorded while subjects were normothermic (34 degrees C water-perfusing suit) and every 10 min during passive heating (48 degrees C water-perfusing suit). RESULTS: Heart rate (ECG), mean skin temperature (weighted six-site average), skin blood flow (laser Doppler flowmetry), and sweat rate (capacitance hygrometry) were all significantly elevated at the end of heating (all P < 0.001). Pre-heat stress temporal-derived temperature was not different from intestinal temperature (36.98 +/- 0.09 vs 37.01 +/- 0.09 degrees C, respectively, P = 0.76). However, after 30 min of heating (the greatest duration of heating completed by all subjects), temporal-derived temperature decreased to below the pre-heat stress baseline (-0.22 +/- 0.11), whereas intestinal temperature increased by 0.39 +/- 0.07 degrees C (P < 0.001 between the two methods). After 50 min of heating (N = 11), intestinal-derived internal temperature increased by 0.70 +/- 0.09 degrees C, whereas temporal-derived temperature decreased by 0.29 +/- 0.10 degrees C (P < 0.001). The group average (+/- SEM) R2 and slope between the two methods were 0.29 +/- 0.08 and -0.34 +/- 0.14, respectively. CONCLUSION: These results demonstrate that temporal scanning does not track internal temperature, as measured via intestinal temperature, during passive heating. Given these findings, it is recommended that this technique not be used to assess temperature in hyperthermic diaphoretic subjects.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1249/mss.0b013e318050ca3e

Cites

1 of 1 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cited by

Metadata

Authors
LOW, D. A., VU, A., BROWN, M., DAVIS, S. L., KELLER, D. M., LEVINE, B. D., & CRANDALL, C. G.
Venue
Medicine & Science in Sports & Exercise
Published
2007-07
Volume
39
Issue
7
Pages
1029-1035
ISSN
0195-9131 (ISSN-L)
OpenAlex
W2042371599
Cited by
41
References
1
FWCI
1.38
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.