CoChat

Actigraph Accelerometer Interinstrument Reliability during Free-Living in Adults

MCCLAIN, JAMES J., SISSON, SUSAN B., TUDOR-LOCKE, CATRINE · 2007 · Medicine & Science in Sports & Exercise
Cited by 145

The DOI matches its Crossref record; 3 of the 3 references it cites were found in a registry or an index.

Abstract

UNLABELLED: The Actigraph (AG; model 7164 v. 2.2) accelerometer is widely accepted as a valid means of physical activity (PA) assessment. However, no studies have investigated interinstrument reliability for data collection in a free-living condition. PURPOSE: To determine agreement (on raw outputs and derived variables) between AG accelerometers worn concurrently on the right hip (RH) and left hip (LH) during 24 h of free-living. METHODS: Ten distinct pairings of AG were evaluated on 10 participants (four males, six females; age=30.1+/-3.8 yr). AG were worn during waking hours (other than water activities). Raw outputs were activity counts and steps. Derived variables were time (minutes) in sedentary, light, moderate, vigorous, and MVPA (moderate+vigorous) intensity using published cut points. Intraclass correlations (ICC), absolute percent error (APE), coefficient of variation (CV), and paired t-tests were evaluated between accelerometers. RESULTS: Raw variables of total activity counts and steps, and derived variables of time in sedentary, light, vigorous, and MVPA intensity displayed high interinstrument reliability. The ICC, APE, and CV values for moderate intensity were 0.98, 18.8%, and 13.5% and, for MVPA, 0.99, 3.7%, and 4.9%, respectively. Only MVPA displayed a statistically significant mean difference (2 min) between RH versus LH AG, but the effect size was small (ES=0.07). CONCLUSION: Results display evidence of decreased interinstrument reliability of moderate-intensity time assessed during free-living. If separate moderate and vigorous categories are not necessary for specific research questions, MVPA may be the optimal intensity range to report, at least in terms of interinstrument reliability.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1249/mss.0b013e3180dc9954

Cites

3 of 3 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 3 references

Cited by

Metadata

Authors
MCCLAIN, J. J., SISSON, S. B., & TUDOR-LOCKE, C.
Venue
Medicine & Science in Sports & Exercise
Published
2007-09
Volume
39
Issue
9
Pages
1509-1514
ISSN
0195-9131 (ISSN-L)
OpenAlex
W2064860072
Cited by
145
References
3
FWCI
3.96
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.