The DOI matches its Crossref record; 1 of the 1 references it cites were found in a registry or an index.
Assessment of Speed and Position during Human Locomotion Using Nondifferential GPS
Abstract
PURPOSE: To validate a nondifferential global positioning system (GPS) to measure speed, displacement, and position during human locomotion. METHODS: Three healthy participants walked and ran over straight and curved courses for 59 and 34 trials, respectively. A nondifferential GPS receiver provided speed data by Doppler shift and change in GPS position over time, which were compared with actual speeds determined by chronometry. Displacement data from the GPS were compared with a surveyed 100-m section, and static positions were collected for 1 h and compared with the known geodetic point. RESULTS: GPS speed values on the straight course were closely correlated with actual speeds (Doppler shift: r = 0.9994, P < 0.001, Delta GPS position/time: r = 0.9984, P < 0.001). Actual speed errors were lowest using the Doppler shift method (90.8% of values within +/- 0.1 m x s(-1)). Speed was slightly underestimated on a curved path, though still highly correlated with actual speed (Doppler shift: r = 0.9985, P < 0.001, Delta GPS distance/time: r = 0.9973, P < 0.001). Distance measured by GPS was 100.46 +/- 0.49 m, and 86.5% of static points were within 1.5 m of the actual geodetic point (mean error: 1.08 +/- 0.34 m, range 0.69-2.10 m). CONCLUSIONS: Nondifferential GPS demonstrated a highly accurate estimation of speed across a wide range of human locomotion velocities using only the raw signal data with a minimal decrease in accuracy around bends. This high level of resolution was matched by accurate displacement and position data. Coupled with reduced size, cost, and ease of use, this method offers a valid alternative to differential GPS in the study of overground locomotion.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
ATS Statement: Guidelines for the Six-Minute Walk Test
(2002) · American Journal of Respiratory and Critical Care Medicine · doi:10.1164/ajrccm.166.1.at1102 · Cited by 11,195
Cited by
The Smartphone Psychology Manifesto
Miller, G. (2012) · Perspectives on Psychological Science · doi:10.1177/1745691612441215 · Cited by 624
Worringham, C., Rojek, A., & Stewart, I. (2011) · PLoS ONE · doi:10.1371/journal.pone.0014669 · Cited by 202
Self-citationMovement patterns in cricket vary by both position and game format.
Petersen, C. J., Pyne, D., Dawson, B., Portus, M., & Kellett, A. (2010) · Journal of Sports Sciences · doi:10.1080/02640410903348665 · Cited by 182
Loveday, A., Sherar, L. B., Sanders, J. P., Sanderson, P. W., & Esliger, D. W. (2015) · Journal of Medical Internet Research · doi:10.2196/jmir.4761 · Cited by 70
Validity of the Stryd power meter in measuring running parameters at submaximal speeds
Imbach, F., Candau, R., Chailan, R., & Perrey, S. (2020) · Sports · doi:10.3390/sports8070103 · Cited by 72
Metadata
- Authors
- TOWNSHEND, A. D., WORRINGHAM, C. J., & STEWART, I. B.
- Venue
- Medicine & Science in Sports & Exercise
- Published
- 2008-01
- Volume
- 40
- Issue
- 1
- Pages
- 124-132
- ISSN
- 0195-9131 (ISSN-L)
- OpenAlex
- W1987059554
- Cited by
- 178
- References
- 1
- FWCI
- 25.29
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Assessment of Speed and Position during Human Locomotion Using Nondifferential GPS. https://app.cochat.ai/papers/10.1249/mss.0b013e3181590bc2
- The paper
- TOWNSHEND, A. D., WORRINGHAM, C. J., & STEWART, I. B. (2008). Assessment of Speed and Position during Human Locomotion Using Nondifferential GPS. Medicine & Science in Sports & Exercise. https://doi.org/10.1249/mss.0b013e3181590bc2
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.