Validity of the Stryd Power Meter in Measuring Running Parameters at Submaximal Speeds
Open accessThe DOI matches its Crossref record; 61 of the 62 references it cites were found in a registry or an index.
Abstract
This study assessed the Stryd running power meter validity at sub-maximal speeds (8 to 19 km/h). Six recreational runners performed an incremental indoor running test. Power output (PO), ground contact time (GCT) and leg spring stiffness (LSS) were compared to reference measures recorded by portable metabolic analyser, force platforms and motion capture system. A Bayesian framework was conducted for systems validity and comparisons. We observed strong and positive linear relationships between Stryd PO and oxygen consumption ( R 2 = 0.82 , B F 10 > 100 ), and between Stryd PO and external mechanical power ( R 2 = 0.88 , B F 10 > 100 ). Stryd power meter underestimated PO ( B F 10 > 100 ) whereas GCT and LSS values did not show any significant differences with the reference measures ( B F 10 = 0.008 , B F 10 = 0.007 , respectively). We conclude that the Stryd power meter provides valid measures of GCT and LSS but underestimates the absolute values of PO.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Figures

![Figure 2 Mechanical stride changes during the MAS test. The top plots (a,b) represent changes in GCT over speed and stride frequency respectively. The bottom plots (c,d) represent changes in leg stiffness (kleg) over speed and stride frequency according to McMahon and Cheng [22]. In each figures, dots represent the group mean values, error bars the standard deviation in both x, y axes. The solid line is the regression line from the Bayesian linear model, surrounded by the 95% credible intervals.](https://figures.cochat.ai/paper-figures/01e73a6d9c1844629d06f725e2ba1430/validity-of-the-stryd-power-meter-in-measuring-running-parameters-at-submaximal-figure-2.jpg)



Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
The source backs part of the claim, not all of it — or backs it for a different population, condition or comparison.
In the citing paper
“The same applied to the validity and reliability of the running power meter (Stryd) for variables of contact time and leg spring stiffness during a maximal incremental test (Imbach et al., 2020).”
From The relationship of muscle oxygen saturation analyzer with other monitoring and quantification tools in a maximal incremental treadmill test (2023) · cites this paper as Imbach et al., 2020
Experimental — accuracy not yet measuredThe cited source says what the claim attributes to it.
In the citing paper
“Also, the study showed that it is a useful tool for quantifying running intensity at submaximal speeds (Imbach et al., 2020).”
From The relationship of muscle oxygen saturation analyzer with other monitoring and quantification tools in a maximal incremental treadmill test (2023) · cites this paper as Imbach et al., 2020
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
STATISTICAL METHODS FOR ASSESSING AGREEMENT BETWEEN TWO METHODS OF CLINICAL MEASUREMENT
Martin Bland, J., & Altman, D. (1986) · The Lancet · doi:10.1016/s0140-6736(86)90837-8 · Cited by 47,965
Random effects structure for confirmatory hypothesis testing: Keep it maximal
Barr, D. J., Levy, R., Scheepers, C., & Tily, H. J. (2013) · Journal of Memory and Language · doi:10.1016/j.jml.2012.11.001 · Cited by 10,328 · cited 1×
“Through a design-driven approach [35], subject varying intercept and slopes were included in addition to fixed effects.”
Methodbrms : An R Package for Bayesian Multilevel Models Using Stan
Bürkner, P.-C. (2017) · Journal of Statistical Software · doi:10.18637/jss.v080.i01 · Cited by 9,476 · cited 1×
“Bayes factors were estimated through a bridge sampling and using the R package “brms” [39].”
MethodVehtari, A., Gelman, A., Simpson, D., Carpenter, B., & Bürkner, P.-C. (2021) · Bayesian Analysis · doi:10.1214/20-ba1221 · Cited by 1,810 · cited 1×
“The Hamilton Monte Carlo algorithm was used to infer the parameters of models and caution has been taken to diagnose their convergence [32].”
MethodBayesian Cognitive Modeling: A Practical Course
Lee, M. D., & Wagenmakers, E.-J. (2014) · doi:10.1017/cbo9781139087759 · Cited by 1,795
The spring-mass model for running and hopping
Blickhan, R. (1989) · Journal of Biomechanics · doi:10.1016/0021-9290(89)90224-8 · Cited by 1,673
The mechanics of running: How does stiffness couple with speed?
McMahon, T. A., & Cheng, G. C. (1990) · Journal of Biomechanics · doi:10.1016/0021-9290(90)90042-2 · Cited by 1,121
Leg stiffness and stride frequency in human running
Farley, C. T., & González, O. (1996) · Journal of Biomechanics · doi:10.1016/0021-9290(95)00029-1 · Cited by 737
Mechanical work and efficiency in level walking and running
Cavagna, G. A., & Kaneko, M. (1977) · The Journal of Physiology · doi:10.1113/jphysiol.1977.sp011866 · Cited by 664
The Slow Component of Oxygen Uptake Kinetics in Humans
GAESSER, G. A., & POOLE, D. C. (1996) · Exercise and Sport Sciences Reviews · doi:10.1249/00003677-199600240-00004 · Cited by 663
Research works printed but not linked: 2
- Smith S. Digital Signal Processing: A Practical Guide for Engineers and Scientists Elsevier Burlington, MA, USA 2013
- Jeffreys H. Theory of Probability Oxford Univ. Press Oxford, UK 1961
Cited by
Wearables for Running Gait Analysis: A Systematic Review
Mason, R., Pearson, L. T., Barry, G., Young, F., Lennon, O., Godfrey, A., & Stuart, S. (2022) · Sports Medicine · doi:10.1007/s40279-022-01760-6 · Cited by 196
Migliaccio, G. M., Padulo, J., & Russo, L. (2024) · Applied Sciences · doi:10.3390/app14156649 · Cited by 95
Ruiz‐Alias, S. A., Olaya-Cuartero, J., Ñancupil‐Andrade, A. A., & García‐Pinillos, F. (2022) · International Journal of Sports Physiology and Performance · doi:10.1123/ijspp.2022-0069 · Cited by 53
Training Monitoring in Sports: It Is Time to Embrace Cognitive Demand
Perrey, S. (2022) · Sports · doi:10.3390/sports10040056 · Cited by 52
Self-citationRunning power: lab based vs . portable devices measurements and its relationship with aerobic power
Taboga, P., Giovanelli, N., Spinazzè, E., Cuzzolin, F., Fedele, G., Zanuso, S., & Lazzer, S. (2021) · European Journal of Sport Science · doi:10.1080/17461391.2021.1966104 · Cited by 42
Metadata
- Authors
- Imbach, F., Candau, R., Chailan, R., & Perrey, S.
- Affiliations
- Institut National de Recherche pour l'Agriculture, l'Alimentation et l'Environnement (FR)
- Seenovate, 34000 Montpellier, France
- EuroMov Digital Health in Motion, Univ Montpellier, IMT Mines Ales, 34090 Montpellier, France
- Corresponding author
- Imbach, Frank
- Venue
- Sports
- Publisher
- MDPI AG
- Published
- 2020-07-20
- Volume
- 8
- Issue
- 7
- Pages
- 103
- ISSN
- 2075-4663 (ISSN-L)
- PMC
- PMC7404478
- OpenAlex
- W3044114303
- Cited by
- 72
- References
- 62
- Citations by year
- 2026: 9 · 2025: 14 · 2024: 13 · 2023: 21 · 2022: 8 · 2021: 7
- FWCI
- 9.00
- Type
- journal article
- Language
- en
- Open access
- gold
- doi.org
- Licence
- Locations
- Sports (publishedVersion, cc-by)
- PubMed Central (publishedVersion, cc-by)
- PubMed (publishedVersion)
- HAL (submittedVersion, cc-by)
- DOAJ (DOAJ: Directory of Open Access Journals) (submittedVersion, cc-by-sa)
- Funders
- Association Nationale de la Recherche et de la Technologie (2018/0653)
- Topics
- Health Sciences › Medicine › Orthopedics and Sports Medicine › Sports Performance and Training
- Physical Sciences › Engineering › Biomedical Engineering › Lower Extremity Biomechanics and Pathologies
- Physical Sciences › Engineering › Biomedical Engineering › Sports Dynamics and Biomechanics
- Keywords
- running power, ground contact time, oxygen consumption, incremental running test, recreational runners
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Validity of the Stryd Power Meter in Measuring Running Parameters at Submaximal Speeds. https://app.cochat.ai/papers/10.3390/sports8070103
- The paper
- Imbach, F., Candau, R., Chailan, R., & Perrey, S. (2020). Validity of the Stryd Power Meter in Measuring Running Parameters at Submaximal Speeds. Sports. https://doi.org/10.3390/sports8070103
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.