CoChat

Validity of the Stryd Power Meter in Measuring Running Parameters at Submaximal Speeds

Open access
Imbach, Frank, Candau, Robin, Chailan, Romain, Perrey, Stephane · 2020 · Sports

The DOI matches its Crossref record; 61 of the 62 references it cites were found in a registry or an index.

Abstract

This study assessed the Stryd running power meter validity at sub-maximal speeds (8 to 19 km/h). Six recreational runners performed an incremental indoor running test. Power output (PO), ground contact time (GCT) and leg spring stiffness (LSS) were compared to reference measures recorded by portable metabolic analyser, force platforms and motion capture system. A Bayesian framework was conducted for systems validity and comparisons. We observed strong and positive linear relationships between Stryd PO and oxygen consumption ( R 2 = 0.82 , B F 10 > 100 ), and between Stryd PO and external mechanical power ( R 2 = 0.88 , B F 10 > 100 ). Stryd power meter underestimated PO ( B F 10 > 100 ) whereas GCT and LSS values did not show any significant differences with the reference measures ( B F 10 = 0.008 , B F 10 = 0.007 , respectively). We conclude that the Stryd power meter provides valid measures of GCT and LSS but underestimates the absolute values of PO.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.3390/sports8070103

Cites

61 of 61 references verified0 citation errors · 0 not checkable

Statistics

Figures

Figure 1 MAS test protocol on a 200 m indoor track. The symbol a represents the start line, b is a photoelectric cell to reset the force platform records, both c are the two motion analysis sensor modules, d is the control panel and e are the cones laid every 20 m and FP is the force platform recording area.
Figure 1 MAS test protocol on a 200 m indoor track. The symbol a represents the start line, b is a photoelectric cell to reset the force platform records, both c are the two motion analysis sensor modules, d is the control panel and e are the cones laid every 20 m and FP is the force platform recording area.CC BY · PubMed Central
Figure 2 Mechanical stride changes during the MAS test. The top plots (a,b) represent changes in GCT over speed and stride frequency respectively. The bottom plots (c,d) represent changes in leg stiffness (kleg) over speed and stride frequency according to McMahon and Cheng [22]. In each figures, dots represent the group mean values, error bars the standard deviation in both x, y axes. The solid line is the regression line from the Bayesian linear model, surrounded by the 95% credible intervals.
Figure 2 Mechanical stride changes during the MAS test. The top plots (a,b) represent changes in GCT over speed and stride frequency respectively. The bottom plots (c,d) represent changes in leg stiffness (kleg) over speed and stride frequency according to McMahon and Cheng [22]. In each figures, dots represent the group mean values, error bars the standard deviation in both x, y axes. The solid line is the regression line from the Bayesian linear model, surrounded by the 95% credible intervals.CC BY · PubMed Central
Figure 3 Consumed metabolic energy (V˙O2) – Stryd power output (PO) relationship during the incremental test. A strong and positive linear relationship was observed across participants. Lines represent each individual linear regression between V˙O2 and PO.
Figure 3 Consumed metabolic energy (V˙O2) – Stryd power output (PO) relationship during the incremental test. A strong and positive linear relationship was observed across participants. Lines represent each individual linear regression between V˙O2 and PO.CC BY · PubMed Central
Figure 4 Comparison of PO estimated by the Stryd power meter and the force platform. The left plot (a) represents the strong positive relationship between the Stryd and the reference measures. The right plot (b) represents the averaged PO in response to speed, where the dotted line is the corrected Stryd PO (see text for details).
Figure 4 Comparison of PO estimated by the Stryd power meter and the force platform. The left plot (a) represents the strong positive relationship between the Stryd and the reference measures. The right plot (b) represents the averaged PO in response to speed, where the dotted line is the corrected Stryd PO (see text for details).CC BY · PubMed Central
Figure 5 Bland–Altman plots for comparison of measurements between the force platforms (reference) and the power meter. Mean bias (middle dashed line), lower and upper limits of agreement (dashed lines) and their 95% confidence interval areas are represented.
Figure 5 Bland–Altman plots for comparison of measurements between the force platforms (reference) and the power meter. Mean bias (middle dashed line), lower and upper limits of agreement (dashed lines) and their 95% confidence interval areas are represented.CC BY · PubMed Central

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Claims other papers make about this one

Each is checked against this paper’s own text: does it say what the citing paper says it does?

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 61 references

Research works printed but not linked: 2

  1. Smith S. Digital Signal Processing: A Practical Guide for Engineers and Scientists Elsevier Burlington, MA, USA 2013
  2. Jeffreys H. Theory of Probability Oxford Univ. Press Oxford, UK 1961

Cited by

See all 88

Metadata

Authors
Imbach, F., Candau, R., Chailan, R., & Perrey, S.
Affiliations
  • Institut National de Recherche pour l'Agriculture, l'Alimentation et l'Environnement (FR)
  • Seenovate, 34000 Montpellier, France
  • EuroMov Digital Health in Motion, Univ Montpellier, IMT Mines Ales, 34090 Montpellier, France
Corresponding author
Imbach, Frank
Venue
Sports
Publisher
MDPI AG
Published
2020-07-20
Volume
8
Issue
7
Pages
103
ISSN
2075-4663 (ISSN-L)
OpenAlex
W3044114303
Cited by
72
References
62
Citations by year
2026: 9 · 2025: 14 · 2024: 13 · 2023: 21 · 2022: 8 · 2021: 7
FWCI
9.00
Type
journal article
Language
en
Open access
Locations
  • Sports (publishedVersion, cc-by)
  • PubMed Central (publishedVersion, cc-by)
  • PubMed (publishedVersion)
  • HAL (submittedVersion, cc-by)
  • DOAJ (DOAJ: Directory of Open Access Journals) (submittedVersion, cc-by-sa)
Funders
Association Nationale de la Recherche et de la Technologie (2018/0653)
Topics
  • Health Sciences › Medicine › Orthopedics and Sports Medicine › Sports Performance and Training
  • Physical Sciences › Engineering › Biomedical Engineering › Lower Extremity Biomechanics and Pathologies
  • Physical Sciences › Engineering › Biomedical Engineering › Sports Dynamics and Biomechanics
Keywords
running power, ground contact time, oxygen consumption, incremental running test, recreational runners

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Validity of the Stryd Power Meter in Measuring Running Parameters at Submaximal Speeds. https://app.cochat.ai/papers/10.3390/sports8070103
The paper
Imbach, F., Candau, R., Chailan, R., & Perrey, S. (2020). Validity of the Stryd Power Meter in Measuring Running Parameters at Submaximal Speeds. Sports. https://doi.org/10.3390/sports8070103

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.