Assessment of Wear/Nonwear Time Classification Algorithms for Triaxial Accelerometer
Open accessAbstract
PURPOSE: The objective of this study is to assess the performance of existing wear/nonwear time classification algorithms for accelerometry data collected in the free-living environment using a wrist-worn triaxial accelerometer and a waist-worn uniaxial accelerometer in older adults. METHODS: Twenty-nine adults age 76 to 96 yr wore wrist accelerometers for approximately 24 h per day and waist accelerometers during waking for approximately 7 d of free living. Wear and nonwear times were classified by existing algorithms (Alg([ActiLife]), Alg([Troiano]), and Alg([Choi])) and compared with wear and nonwear times identified by data plots and diary records. With the use of bias and probability of correct classification, the performance of the algorithms, two time windows (60 and 90 min), and vector magnitude (VM) versus vertical axis (V) counts from a triaxial accelerometer were compared. RESULTS: Automated algorithms (Alg([Choi]) and Alg([Troiano])) classified wear/nonwear time intervals more accurately from VM than V counts. The use of the 90-min time window improved wear/nonwear classification accuracy when compared with the 60-min window. The Alg([Choi]) and Alg([Troiano]) performed better than the manufacturer-provided algorithm (Alg([ActiLife])), and the Alg([Choi]) performed better than the Alg([Troiano]) for wear/nonwear time classification using the data collected by both accelerometers. CONCLUSIONS: Triaxial wrist-worn accelerometer can be used for an accurate wear/nonwear time classification in free-living older adults. The use of the 90-min window and the VM counts improves the performance of commonly used algorithms for wear/nonwear classification for both uniaxial and triaxial accelerometers.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Physical Activity in the United States Measured by Accelerometer
TROIANO, R. P., BERRIGAN, D., DODD, K. W., MÂSSE, L. C., TILERT, T., & MCDOWELL, M. (2008) · Medicine & Science in Sports & Exercise · doi:10.1249/mss.0b013e31815a51b3 · Cited by 7,638
Gait speed and survival in older adults.
Studenski, S. (2011) · JAMA · doi:10.1001/jama.2010.1923 · Cited by 4,558
Amount of Time Spent in Sedentary Behaviors in the United States, 2003-2004
Matthews, C. E., Chen, K. Y., Freedson, P. S., Buchowski, M. S., Beech, B. M., Pate, R. R., & Troiano, R. P. (2008) · American Journal of Epidemiology · doi:10.1093/aje/kwm390 · Cited by 2,631
Self-citationTalbot, L. A., Morrell, C. H., Fleg, J. L., & Metter, E. J. (2007) · Preventive Medicine · doi:10.1016/j.ypmed.2007.05.014 · Cited by 121
Progress Toward the Healthy People 2010 Goals and Objectives
Sondik, E. J., Huang, D. T., Klein, R. J., & Satcher, D. (2010) · Annual Review of Public Health · doi:10.1146/annurev.publhealth.012809.103613 · Cited by 96
Cited by
Association of Step Volume and Intensity With All-Cause Mortality in Older Women
Lee, I.-M., Shiroma, E. J., Kamada, M., Bassett, D. R., Matthews, C. E., & Buring, J. E. (2019) · JAMA Internal Medicine · doi:10.1001/jamainternmed.2019.0899 · Cited by 604
Reproducibility of Accelerometer-Assessed Physical Activity and Sedentary Time
Keadle, S. K., Shiroma, E. J., Kamada, M., Matthews, C. E., Harris, T. B., & Lee, I.-M. (2017) · American Journal of Preventive Medicine · doi:10.1016/j.amepre.2016.11.010 · Cited by 105
Normative Steps/Day Values for Older Adults: NHANES 2005-2006
Tudor-Locke, C., Schuna, J. M., Barreira, T. V., Mire, E. F., Broyles, S. T., Katzmarzyk, P. T., & Johnson, W. D. (2013) · The Journals of Gerontology Series A: Biological Sciences and Medical Sciences · doi:10.1093/gerona/glt116 · Cited by 110
LaMonte, M. J., Lewis, C. E., Buchner, D. M., Evenson, K. R., Rillamas‐Sun, E., Di, C., Lee, I., Bellettiere, J., Stefanick, M. L., Eaton, C. B., et al. (2017) · Journal of the American Heart Association · doi:10.1161/jaha.117.007064 · Cited by 97
Accelerometer‐Measured Physical Activity and Mortality in Women Aged 63 to 99
LaMonte, M. J., Buchner, D. M., Rillamas‐Sun, E., Di, C., Evenson, K. R., Bellettiere, J., Lewis, C. E., Lee, I., Tinker, L. F., Seguin, R., et al. (2018) · Journal of the American Geriatrics Society · doi:10.1111/jgs.15201 · Cited by 94
Metadata
- Authors
- CHOI, L., WARD, S. C., SCHNELLE, J. F., & BUCHOWSKI, M. S.
- Venue
- Medicine & Science in Sports & Exercise
- Published
- 2012-10
- Volume
- 44
- Issue
- 10
- Pages
- 2009-2016
- ISSN
- 0195-9131 (ISSN-L)
- OpenAlex
- W1982562953
- Cited by
- 478
- References
- 5
- FWCI
- 6.98
- Type
- journal article
- Language
- en
- Open access
- green
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Assessment of Wear/Nonwear Time Classification Algorithms for Triaxial Accelerometer. https://app.cochat.ai/papers/10.1249/mss.0b013e318258cb36
- The paper
- CHOI, L., WARD, S. C., SCHNELLE, J. F., & BUCHOWSKI, M. S. (2012). Assessment of Wear/Nonwear Time Classification Algorithms for Triaxial Accelerometer. Medicine & Science in Sports & Exercise. https://doi.org/10.1249/mss.0b013e318258cb36
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.