Thinking outside the Bag (Not Necessarily outside the Lab)
The DOI matches its Crossref record.
Abstract
Dear Editor-in-Chief: As avid users of the Douglas bag technique for indirect calorimetry in our own research, we found the commentary “Who Needs a Bag?” deeply affirming (2). We wholeheartedly resonate with the key messages that the method remains a state-of-the-art gold standard and should accordingly form a core element of research training in the “first principles” of metabolic assessment. This commentary was prompted by an equally eloquent original article in the same issue by Hopker et al. (3), who neatly evaluated potential sources of error at various steps in the process of sampling and analyzing expired gases. In doing so, however, the authors have inadvertently highlighted what appears to be an altogether overlooked and therefore widespread error in indirect calorimetric analysis arising from our long-standing reliance on the assumption that inspired gas fractions are both stable and reflective of atmospheric constants. (Hopker et al. quote the commonly cited but rarely referenced values of 20.93% oxygen and 0.03% carbon dioxide.) Although the assumed constant of 0.03% carbon dioxide might well have been valid at the beginning of the 20th century when the principles of indirect calorimetry were first realized (4) and Douglas (1) initially described his now classic method of collecting expired gases, atmospheric carbon dioxide content has since risen exponentially, with mean global values having rounded to 0.04% for over two decades already and due to surpass that absolute figure this year for the first time in human history (6). Moreover, the commonly adopted constant of 20.93% oxygen remains derived from the highly variable range of values reported until recently (5), yet reliable atmospheric oxygen data only became available within the past two decades and already reveal a decrease >0.03% in that time alone, reaching the current nadir of 20.95% (i.e., past values deviated even further from those assumed (7)). Basing contemporary calculations of metabolic substrate oxidation on atmospheric values estimated before the industrial revolution therefore systematically underestimates energy expenditure by approximately 0.6%, yet the outdated constants still widely cited in our field suggest that the extent of recent changes in atmospheric composition is not common knowledge. (Indeed, we had to search beyond the human physiology/metabolism literature to ascertain the above values.) Irrespective of global climate change, however, even well-ventilated laboratories unavoidably become “contaminated” with inhabitants’ expired gases such that ambient air about the participant can readily approach 0.1% carbon dioxide and 20.7% oxygen over the course of testing. Under such conditions, energy expenditure would be gradually overestimated by up to 7%. Unlike random errors, which can largely be managed by replicate samples/analyses to dilute “noise” in measurement, such systematic bias clearly holds profound implications for interpretation of metabolic assessments using indirect calorimetry. We therefore propose that that the composition of the ambient air actually inspired should be measured (i.e., outside the Douglas bag proximal to the participant’s mouthpiece) with these values used relative to each corresponding expired gas sample, as opposed to simply assuming constants for atmospheric air that is neither constant nor inspired. James A. Betts Dylan Thompson Human Physiology Research Group Department for Health University of Bath Bath, United Kingdom
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Gonzalez, J. T., Fuchs, C. J., Smith, F. E., Thelwall, P. E., Taylor, R., Stevenson, E. J., Trenell, M. I., Cermak, N. M., & van Loon, L. J. C. (2015) · American Journal of Physiology-Endocrinology and Metabolism · doi:10.1152/ajpendo.00376.2015 · Cited by 95
Assessment of maximal fat oxidation during exercise: A systematic review
Amaro‐Gahete, F. J., Sanchez‐Delgado, G., Jurado‐Fasoli, L., De‐la‐O, A., Castillo, M. J., Helge, J. W., & Ruiz, J. R. (2019) · Scandinavian Journal of Medicine & Science in Sports · doi:10.1111/sms.13424 · Cited by 93
Gray, E. A., Green, T. A., Betts, J. A., & Gonzalez, J. T. (2020) · International Journal of Sport Nutrition and Exercise Metabolism · doi:10.1123/ijsnem.2019-0211 · Cited by 15
Self-citation
Metadata
- Authors
- Betts, J. A., & Thompson, D.
- Venue
- Medicine & Science in Sports & Exercise
- Published
- 2012-10
- Volume
- 44
- Issue
- 10
- Pages
- 2040
- ISSN
- 0195-9131 (ISSN-L)
- OpenAlex
- W1983522368
- Cited by
- 66
- References
- 0
- FWCI
- 3.01
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Thinking outside the Bag (Not Necessarily outside the Lab). https://app.cochat.ai/papers/10.1249/mss.0b013e318264526f
- The paper
- Betts, J. A., & Thompson, D. (2012). Thinking outside the Bag (Not Necessarily outside the Lab). Medicine & Science in Sports & Exercise. https://doi.org/10.1249/mss.0b013e318264526f
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.