The DOI matches its Crossref record; 45 of the 45 references it cites were found in a registry or an index.
Techniques of EMG signal analysis: detection, processing, classification and applications
Open accessAbstract
Electromyography (EMG) signals can be used for clinical/biomedical applications, Evolvable Hardware Chip (EHW) development, and modern human computer interaction. EMG signals acquired from muscles require advanced methods for detection, decomposition, processing, and classification. The purpose of this paper is to illustrate the various methodologies and algorithms for EMG signal analysis to provide efficient and effective ways of understanding the signal and its nature. We further point up some of the hardware implementations using EMG focusing on applications related to prosthetic hand control, grasp recognition, and human computer interaction. A comparison study is also given to show performance of various EMG signal analysis methods. This paper provides researchers a good understanding of EMG signal and its analysis procedures. This knowledge will help them develop more powerful, flexible, and efficient applications.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Габор, Д. (1946) · Journal of the IEE · Cited by 5,036
The Use of Surface Electromyography in Biomechanics
De Luca, C. J. (1997) · Journal of Applied Biomechanics · doi:10.1123/jab.13.2.135 · Cited by 3,268
(2009) · Encyclopedia of Neuroscience · doi:10.1007/978-3-540-29678-2_6014 · Cited by 2,850
(1996) · Adapted Wavelet Analysis · doi:10.1201/9781439863619-15 · Cited by 2,703
Bispectrum estimation: A digital signal processing framework
Nikias, C. L., & Raghuveer, M. R. (1987) · Proceedings of the IEEE · doi:10.1109/proc.1987.13824 · Cited by 1,377
Introduction to Surface Electromyography
Cram, J. R., Kasman, G. S., & Holtz, J. (1998) · Cited by 1,199
Higher order spectra analysis, a nonlinear signal processing framework
(1994) · Control Engineering Practice · doi:10.1016/0967-0661(94)90335-2 · Cited by 1,133
Signal processing with higher-order spectra
Nikias, C. L., & Mendel, J. M. (1993) · IEEE Signal Processing Magazine · doi:10.1109/79.221324 · Cited by 952
Introduction to Surface Electromyography
Pope, G. D. (1998) · Physiotherapy · doi:10.1016/s0031-9406(05)61482-4 · Cited by 841
Electrophysiological estimation of the number of motor units within a human muscle
McComas, A. J., Fawcett, P. R. W., Campbell, M. J., & Sica, R. E. P. (1971) · Journal of Neurology, Neurosurgery & Psychiatry · doi:10.1136/jnnp.34.2.121 · Cited by 666
Wigner-Ville spectral analysis of nonstationary processes
Martin, W., & Flandrin, P. (1985) · IEEE Transactions on Acoustics, Speech, and Signal Processing · doi:10.1109/tassp.1985.1164760 · Cited by 554
Ramachandra Rao, A., Hamed, K. H., & Chen, H.-L. (2003) · Water Science and Technology Library · doi:10.1007/978-94-010-0117-5_5 · Cited by 437
Fuzzy EMG classification for prosthesis control
Chan, F. H. Y., Yang, Y.-S., Lam, F. K., Zhang, Y.-T., & Parker, P. A. (2000) · IEEE Transactions on Rehabilitation Engineering · doi:10.1109/86.867872 · Cited by 376
Bonato, P., D'Alessio, T., & Knaflitz, M. (1998) · IEEE Transactions on Biomedical Engineering · doi:10.1109/10.661154 · Cited by 375
Rosenfalck, P. (1969) · PubMed · Cited by 373
Functional Separation of EMG Signals via ARMA Identification Methods for Prosthesis Control Purposes
Graupe, D., & Cline, W. K. (1975) · IEEE Transactions on Systems, Man, and Cybernetics · doi:10.1109/tsmc.1975.5408479 · Cited by 354 · cited 1×
“In 1975, Graupe and Cline (30) first introduced the autoregressive moving average (ARMA) model to represent EMG signals.”
BackgroundA fast and reliable technique for muscle activity detection from surface EMG signals
Merlo, A., Farina, D., & Merletti, R. (2003) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.2003.808829 · Cited by 284
Wavelet analysis of surface electromyography
Kumar, D., Pah, N. D., & Bradley, A. (2003) · IEEE Transactions on Neural Systems and Rehabilitation Engineering · doi:10.1109/tnsre.2003.819901 · Cited by 180
Upper Extremity Limb Function Discrimination Using EMG Signal Analysis
Doerschuk, P. C., Gustafon, D. E., & Willsky, A. S. (1983) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.1983.325162 · Cited by 179
Electromyography in the biomechanical analysis of human movement and its clinical application
Kleissen, R. F. M., Buurke, J. H., Harlaar, J., & Zilvold, G. (1998) · Gait & Posture · doi:10.1016/s0966-6362(98)00025-3 · Cited by 174
Graupe, D., Magnussen, J., & Beex, A. A. L. (1978) · IEEE Transactions on Automatic Control · doi:10.1109/tac.1978.1101783 · Cited by 154
Kanosue, K., Yoshida, M., Akazawa, K., & FUJII, K. (1979) · The Japanese Journal of Physiology · doi:10.2170/jjphysiol.29.427 · Cited by 153
Boashash, B., & O’Shea, P. (1990) · IEEE Transactions on Acoustics Speech and Signal Processing · doi:10.1109/29.103085 · Cited by 147
Analysis of the distribution of the action currents of nerve in volume conductors.
Lorente de No, R. (1947) · PubMed · Cited by 147
A Discrete-Time Model of Electrcally Stimulated Muscle
Bernotas, L. A., Crago, P. E., & Chizeck, H. J. (1986) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.1986.325776 · Cited by 122
Hefftner, G., Zucchini, W., & Jaros, G. G. (1988) · IEEE Transactions on Biomedical Engineering · doi:10.1109/10.1370 · Cited by 120
Physiologically Based Simulation of Clinical EMG Signals
Hamilton-Wright, A., & Stashuk, D. W. (2005) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.2004.840501 · Cited by 116
Duchêne, J., & Hogrel, J. (2000) · IEEE Transactions on Biomedical Engineering · doi:10.1109/10.821754 · Cited by 115
Gestures as input: neuroelectric joysticks and keyboards
Wheeler, K., & Jorgensen, C. C. (2003) · IEEE Pervasive Computing · doi:10.1109/mprv.2003.1203754 · Cited by 106
Time-scale analysis of motor unit action potentials
Pattichis, C. S., & Pattichis, M. S. (1999) · IEEE Transactions on Biomedical Engineering · doi:10.1109/10.797992 · Cited by 105
Pathologic gait diagnosis with computer-averaged electromyographic profiles.
Winter, D. A. (1984) · PubMed · Cited by 103
Improving detection of muscle activation intervals
Micera, S., Vannozzi, G., Sabatini, A. M., & Dario, P. (2001) · IEEE Engineering in Medicine and Biology Magazine · doi:10.1109/51.982274 · Cited by 95
Blind Separation of Linear Instantaneous Mixtures of Nonstationary Surface Myoelectric Signals
Farina, D., Févotte, C., Doncarli, C., & Merletti, R. (2004) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.2004.828048 · Cited by 88
Cheron, G. A., Draye, J.-P., Bourgeios, M., & Libert, G. (1996) · IEEE Transactions on Biomedical Engineering · doi:10.1109/10.488803 · Cited by 86
"Unvoiced speech recognition using EMG - mime speech recognition"
Manabe, H., Hiraiwa, A., & Sugimura, T. (2003) · CHI Conference Extended Abstracts on Human Factors in Computing Systems (CHI EA) · doi:10.1145/765891.765996 · Cited by 77
Thexton, A. J. (1996) · Journal of Neuroscience Methods · doi:10.1016/0165-0270(96)00004-0 · Cited by 73
Simulations of motor unit number estimation techniques
Major, L. A., & Jones, K. E. (2005) · Journal of Neural Engineering · doi:10.1088/1741-2560/2/2/003 · Cited by 39
Continuous wavelet transform application to EMG signals during human gait
Ismail, A., & ASFOUR, S. S. (2002) · Asilomar Conference on Signals, Systems and Computers (ACSSC) · doi:10.1109/acssc.1998.750880 · Cited by 37
Single motor unit myoelectric signal analysis with nonstationary data
Englehart, K. B., & Parker, P. A. (1994) · IEEE Transactions on Biomedical Engineering · doi:10.1109/10.284928 · Cited by 28
An evolvable hardware chip for prosthetic hand controller
Kajitani, I., Murakawa, M., Nishikawa, D., Yokoi, H., Kajihara, N., Iwata, M., Keymeulen, D., Sakanashi, H., & Higuchi, T. (2003) · International Conference on Microelectronics for Neural, Fuzzy and Bio-Inspired Systems (MicroNeuro) · doi:10.1109/mn.1999.758862 · Cited by 25
Investigation on parametric analysis of dynamic EMG signals by a muscle-structured simulation model
Kiryu, T., Saitoh, Y., & Ishioka, K. (1992) · IEEE Transactions on Biomedical Engineering · doi:10.1109/10.125013 · Cited by 21
Estimation of intramuscular EMG signals from surface EMG signal analysis
Zhou, Y.-T., Chellappa, R., & Bekey, G. A. (2005) · IEEE International Conference on Acoustics Speech and Signal Processing · doi:10.1109/icassp.1986.1168914 · Cited by 13
Analog integrated circuit design for the wireless bio-signal transmission system
Yen, C.-J., Chung, W., Lin, K.-P., Tsai, C.-L., Lee, S.-H., & Chen, T.-S. (2003) · AP-ASIC'99. First IEEE Asia Pacific Conference on ASICs (Cat. No.99EX360) · doi:10.1109/apasic.1999.824099 · Cited by 10
Real-time system for EMG signal analysis of static and dynamic contractions
Karlsson, S., & Nyström, L. (2002) · Annual International Conference of the IEEE Engineering in Medicine and Biology Society (EMBC) · doi:10.1109/iembs.1995.579720 · Cited by 3
Estimation of motor unit firing statistics from surface EMG
Xu, Z., & Xiao, S. (2002) · Annual International Conference of the IEEE Engineering in Medicine and Biology Society (EMBC) · doi:10.1109/iembs.1998.745114 · Cited by 2
Cited by
Surface Electromyography Signal Processing and Classification Techniques
Chowdhury, R., Reaz, M., Ali, M., Bakar, A., Chellappan, K., & Chang, T. (2013) · Sensors · doi:10.3390/s130912431 · Cited by 1,000
Self-citationDeep Learning for Electromyographic Hand Gesture Signal Classification Using Transfer Learning
Cote-Allard, U., Fall, C. L., Drouin, A., Campeau-Lecours, A., Gosselin, C., Glette, K., Laviolette, F., & Gosselin, B. (2019) · IEEE Transactions on Neural Systems and Rehabilitation Engineering · doi:10.1109/tnsre.2019.2896269 · Cited by 738
Bi, L., Feleke, A. >., & Guan, C. (2019) · Biomedical Signal Processing and Control · doi:10.1016/j.bspc.2019.02.011 · Cited by 418
Control of Hand Prostheses Using Peripheral Information
Micera, S., Carpaneto, J., & Raspopovic, S. (2010) · IEEE Reviews in Biomedical Engineering · doi:10.1109/rbme.2010.2085429 · Cited by 403
A novel attention-based hybrid CNN-RNN architecture for sEMG-based gesture recognition
Hu, Y., Wong, Y., Wei, W., Du, Y., Kankanhalli, M., & Geng, W. (2018) · PLOS ONE · doi:10.1371/journal.pone.0206049 · Cited by 398
Metadata
- Authors
- Reaz, M. B. I., Hussain, M. S., & Mohd-Yasin, F.
- Venue
- Biological Procedures Online
- Published
- 2006-12
- Volume
- 8
- Issue
- 1
- Pages
- 11-35
- ISSN
- 1480-9222 (ISSN-L)
- OpenAlex
- W2158728671
- Cited by
- 1,629
- References
- 45
- FWCI
- 14.63
- Type
- journal article
- Language
- en
- Open access
- hybrid
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.