Student or educator? Sign up with your school email and get 6 months of Pro free.
Cited by 375

The DOI matches its Crossref record; 21 of the 21 references it cites were found in a registry or an index.

A statistical method for the measurement of muscle activation intervals from surface myoelectric signal during gait

Bonato, P., D'Alessio, T., Knaflitz, M.·1998·IEEE Transactions on Biomedical Engineering

Abstract

The aim of this work is to present an original double-threshold detector of muscle activation, specifically developed for gait analysis. This detector operates on the raw myoelectric signal and, hence, it does not require any envelope detection. Its performances are fixed by the values of three parameters, namely, false-alarm probability (Pfa), detection probability, and time resolution. Double-threshold detectors are preferable to single-threshold ones because, for a fixed value of the Pfa, they yield higher detection probability; furthermore, they allow the user to select the couple false alarm-detection probability with a higher degree of freedom, thus, adapting the performances of the detector to the characteristics of the myoelectric signal of interest and of the experimental situation. In this paper, first we derive the detection algorithm and describe different strategies for selecting its parameters, then we present the performances of the proposed procedure evaluated by means of computer simulations, and finally we report an example of application to myoelectric signals recorded during gait. The characterization of the proposed double-threshold detector demonstrates that, in most practical situations, the bias of the estimates of the on-off transitions is smaller than 10 ms, the standard deviation may be kept lower than 15 ms, and the percentage of erroneous patterns is below 5%. These results show that this detection approach is satisfactory in research applications as well as in the clinical practice.

Overview

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1109/10.661154

Cites

21 of 21 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 21 references

Cited by

See all 375

Metadata

Authors
Bonato, P., D'Alessio, T., & Knaflitz, M.
Venue
IEEE Transactions on Biomedical Engineering
Published
1998-03
Volume
45
Issue
3
Pages
287-299
ISSN
0018-9294 (ISSN-L)
OpenAlex
W2136908787
Cited by
375
References
21
FWCI
3.62
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: A statistical method for the measurement of muscle activation intervals from surface myoelectric signal during gait. https://app.cochat.ai/papers/10.1109/10.661154
The paper
Bonato, P., D'Alessio, T., & Knaflitz, M. (1998). A statistical method for the measurement of muscle activation intervals from surface myoelectric signal during gait. IEEE Transactions on Biomedical Engineering. https://doi.org/10.1109/10.661154

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.