Student or educator? Sign up with your school email and get 6 months of Pro free.
CoChat
Cited by 292

The DOI matches its Crossref record; 10 of the 10 references it cites were found in a registry or an index.

Specific Findings of the Standard 12-Lead ECG in Patients With 'Takotsubo' Cardiomyopathy-Comparison With the Findings of Acute Anterior Myocardial Infarction-

Open access
Ogura, Riyo, Hiasa, Yoshikazu, Takahashi, Takefumi, Yamaguchi, Koji, Fujiwara, Kensuke, Ohara, Yoshikazu, Nada, Teru, Ogata, Tatsuro, Kusunoki, Kanji, Yuba, Kenichiro, Hosokawa, Shinobu, Kishi, Koichi, Ohtani, Ryuji · 2003 · Circulation Journal

Abstract

The clinical course of 'Takotsubo' cardiomyopathy closely resembles that of acute myocardial infarction (AMI) and coronary angiography (CAG) is usually performed to distinguish the 2 conditions during the acute phase. The present study was designed to determine whether the standard 12-lead electrocardiogram (ECG) findings could help to distinguish 'Takotsubo' cardiomyopathy from anterior AMI. The study group comprised 13 patients with 'Takotsubo' cardiomyopathy and 13 consecutive patients with anterior AMI. Patients with 'Takotsubo' cardiomyopathy had abnormal Q waves less frequently than patients with anterior AMI (15% vs 69%, p=0.008). No reciprocal changes were seen in the inferior leads in patients with 'Takotsubo' cardiomyopathy (p=0.0003). The ratio of ST-segment elevation in leads V(4-6) to V(1-3) (SigmaSTeV(4-6)/V(1-3)) was significantly higher in patients with 'Takotsubo' cardiomyopathy (1.55+/-0.53 vs 0.57+/-0.58, p=0.0004). The QTc interval was significantly longer in patients with 'Takotsubo' cardiomyopathy. The absence of reciprocal changes, absence of abnormal Q waves, and a SigmaSTeV(4-6)/V(1-3) >/=1 all showed a high sensitivity and specificity for diagnosing 'Takotsubo' cardiomyopathy. Furthermore, the combination of the absence of reciprocal changes and a SigmaSTeV(4-6)/V (1-3) >/=1 had a greater specificity (100%) and overall accuracy (91%) than either criteria. Therefore, the standard 12-lead ECG on admission can help to distinguish 'Takotsubo' cardiomyopathy from anterior AMI.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1253/circj.67.687

Cites

10 of 10 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 10 references

Cited by

See all 292

Metadata

Authors
Ogura, R., Hiasa, Y., Takahashi, T., Yamaguchi, K., Fujiwara, K., Ohara, Y., Nada, T., Ogata, T., Kusunoki, K., Yuba, K., Hosokawa, S., Kishi, K., & Ohtani, R.
Venue
Circulation Journal
Published
2003
Volume
67
Issue
8
Pages
687-690
ISSN
  • 1346-9843 (ISSN-L)
  • 1347-4820
OpenAlex
W1998446710
Cited by
292
References
10
FWCI
6.50
Type
journal article
Language
en
Open access
bronze

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Specific Findings of the Standard 12-Lead ECG in Patients With 'Takotsubo' Cardiomyopathy-Comparison With the Findings of Acute Anterior Myocardial Infarction-. https://app.cochat.ai/papers/10.1253/circj.67.687
The paper
Ogura, R., Hiasa, Y., Takahashi, T., Yamaguchi, K., Fujiwara, K., Ohara, Y., Nada, T., Ogata, T., Kusunoki, K., Yuba, K., Hosokawa, S., Kishi, K., & Ohtani, R. (2003). Specific Findings of the Standard 12-Lead ECG in Patients With 'Takotsubo' Cardiomyopathy-Comparison With the Findings of Acute Anterior Myocardial Infarction-. Circulation Journal. https://doi.org/10.1253/circj.67.687

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.