Normal Range of Left Ventricular 2-Dimensional Strain: – Japanese Ultrasound Speckle Tracking of the Left Ventricle (JUSTICE) Study –
Open accessThe DOI matches its Crossref record; 19 of the 19 references it cites were found in a registry or an index.
Abstract
BACKGROUND: To determine the normal range of left ventricular (LV) 2- dimensional (2-D) strain and vendor-specific differences, a multicenter prospective 2-D strain study endorsed by the Japanese Society of Echocardiography was conducted. METHODS AND RESULTS: 2-D speckle tracking analysis was performed on 817 healthy subjects (age range, 0-88 years); the images included 3 LV short axis and 3 apical views using an ultrasound system from 1 of the 3 different vendors (V(1), n=333; V(2), n=330; V(3), n=337). With the 2-D speckle tracking software from each vendor, radial, circumferential and longitudinal strain were measured using an 18-segment model. Inter-vendor variability was also assessed in a subset of subjects. The feasibility for 2-D strain measurements was different among the 3 vendors (V(1), 83%; V(2), 70%; V(3), 88%, P<0.01). The global radial (V(1), 54.6±12.6%; V(2), 36.3±8.2%; V(3), 51.4±8.0%), circumferential (V(1), -22.8±2.9%; V(2), -22.2±3.2%; V(3), -30.5±3.8%), and longitudinal (V(1), -21.3±2.1%; V(2), -18.9±2.5%; V(3), -19.9±2.4%) strain measurements were significantly different for each of the vendors. Segmental strain was also different between the 3 vendors. On inter-vendor analysis, vendor agreement ranged from mild to moderate. CONCLUSIONS: Reference values are provided for normal 2-D strain for 3 different ultrasound vendors. Due to a low inter-vendor agreement, 2-D strain data are not interchangeable when conducting a longitudinal follow-up or a cross-sectional assessment of LV function.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Mor-Avi, V., Lang, R. M., Badano, L. P., Belohlavek, M., Cardim, N. M., Derumeaux, G., Galderisi, M., Marwick, T., Nagueh, S. F., Sengupta, P. P., et al. (2011) · Journal of the American Society of Echocardiography · doi:10.1016/j.echo.2011.01.015 · Cited by 1,254
Self-citationNoninvasive Myocardial Strain Measurement by Speckle Tracking Echocardiography
Amundsen, B. H., Helle-Valle, T., Edvardsen, T., Torp, H., Crosby, J., Lyseggen, E., Støylen, A., Ihlen, H., Lima, J. A. C., Smiseth, O. A., et al. (2006) · Journal of the American College of Cardiology · doi:10.1016/j.jacc.2005.10.040 · Cited by 1,252
Leitman, M., Lysyansky, P., Sidenko, S., Shir, V., Peleg, E., Binenbaum, M., Kaluski, E., Krakover, R., & Vered, Z. (2004) · Journal of the American Society of Echocardiography · doi:10.1016/j.echo.2004.06.019 · Cited by 1,187
Global longitudinal strain: a novel index of left ventricular systolic function
Reisner, S. A., Lysyansky, P., Agmon, Y., Mutlak, D., Lessick, J., & Friedman, Z. (2004) · Journal of the American Society of Echocardiography · doi:10.1016/j.echo.2004.02.011 · Cited by 735
Myocardial Strain Measurement With 2-Dimensional Speckle-Tracking Echocardiography
Marwick, T. H., Leano, R. L., Brown, J., Sun, J.-P., Hoffmann, R., Lysyansky, P., Becker, M., & Thomas, J. D. (2009) · JACC: Cardiovascular Imaging · doi:10.1016/j.jcmg.2007.12.007 · Cited by 529
Perk, G., Tunick, P. A., & Kronzon, I. (2007) · Journal of the American Society of Echocardiography · doi:10.1016/j.echo.2006.08.023 · Cited by 501
Dalen, H., Thorstensen, A., Aase, S. A., Ingul, C. B., Torp, H., Vatten, L. J., & Stoylen, A. (2010) · European Heart Journal - Cardiovascular Imaging · doi:10.1093/ejechocard/jep194 · Cited by 356
Langeland, S., D’hooge, J., Wouters, P. F., Leather, H. A., Claus, P., Bijnens, B., & Sutherland, G. R. (2005) · Circulation · doi:10.1161/circulationaha.105.554006 · Cited by 331
Nakai, H., Takeuchi, M., Nishikage, T., Lang, R. M., & Otsuji, Y. (2009) · European Journal of Echocardiography · doi:10.1093/ejechocard/jep097 · Cited by 293
Self-citationGjesdal, O., Hopp, E., Vartdal, T., Lunde, K., Helle-Valle, T., Aakhus, S., Smith, H.-J., Ihlen, H., & Edvardsen, T. (2007) · Clinical Science · doi:10.1042/cs20070066 · Cited by 193
Bansal, M., Cho, G.-Y., Chan, J., Leano, R., Haluska, B. A., & Marwick, T. H. (2008) · Journal of the American Society of Echocardiography · doi:10.1016/j.echo.2008.09.021 · Cited by 186
Koopman, L. P., Slorach, C., Hui, W., Manlhiot, C., McCrindle, B. W., Friedberg, M. K., Jaeggi, E. T., & Mertens, L. (2010) · Journal of the American Society of Echocardiography · doi:10.1016/j.echo.2010.06.014 · Cited by 164
Assessment of left ventricular function by different speckle-tracking software
Manovel, A. J., Dawson, D., Smith, B., & Nihoyannopoulos, P. (2010) · European Journal of Echocardiography · doi:10.1093/ejechocard/jep226 · Cited by 137
Goffinet, C., Chenot, F., Robert, A. R., Pouleur, A., de Waroux, J. L. P., Vancrayenest, D., Gérard, O., Pasquet, A., Gerber, B. L., & Vanoverschelde, J. (2008) · European Heart Journal · doi:10.1093/eurheartj/ehn511 · Cited by 115
Comparison of Two Different Speckle Tracking Software Systems: Does the Method Matter?
Biaggi, P., Carasso, S., Garceau, P., Greutmann, M., Gruner, C., Tsang, W., Rakowski, H., Agmon, Y., & Woo, A. (2011) · Echocardiography · doi:10.1111/j.1540-8175.2011.01386.x · Cited by 81
Ishizu, T., Seo, Y., Enomoto, Y., Sugimori, H., Yamamoto, M., Machino, T., Kawamura, R., & Aonuma, K. (2010) · European Journal of Echocardiography · doi:10.1093/ejechocard/jep221 · Cited by 77
Reckefuß, N., Butz, T., Horstkotte, D., & Faber, L. (2010) · International journal of cardiac imaging · doi:10.1007/s10554-010-9716-y · Cited by 63
Haruki, N., Takeuchi, M., Kanazawa, Y., Tsubota, N., Shintome, R., Nakai, H., Lang, R. M., & Otsuji, Y. (2010) · European Journal of Echocardiography · doi:10.1093/ejechocard/jep215 · Cited by 38
Self-citationYamawaki, K., Tanaka, H., Matsumoto, K., Hiraishi, M., Miyoshi, T., Kaneko, A., Tsuji, T., Ryo, K., Norisada, K., Fukuda, Y., et al. (2011) · Circulation Journal · doi:10.1253/circj.cj-11-1098 · Cited by 17
Cited by
Lang, R. M., Badano, L. P., Mor-Avi, V., Afilalo, J., Armstrong, A., Ernande, L., Flachskampf, F. A., Foster, E., Goldstein, S. A., Kuznetsova, T., et al. (2015) · Journal of the American Society of Echocardiography · doi:10.1016/j.echo.2014.10.003 · Cited by 12,362
Lang, R. M., Badano, L. P., Mor-Avi, V., Afilalo, J., Armstrong, A., Ernande, L., Flachskampf, F. A., Foster, E., Goldstein, S. A., Kuznetsova, T., et al. (2015) · European Heart Journal – Cardiovascular Imaging · doi:10.1093/ehjci/jev014 · Cited by 8,361
Plana, J. C., Galderisi, M., Barac, A., Ewer, M. S., Ky, B., Scherrer-Crosbie, M., Ganame, J., Sebag, I. A., Agler, D. A., Badano, L. P., et al. (2014) · Journal of the American Society of Echocardiography · doi:10.1016/j.echo.2014.07.012 · Cited by 1,795
Voigt, J.-U., Pedrizzetti, G., Lysyansky, P., Marwick, T. H., Houle, H., Baumann, R., Pedri, S., Ito, Y., Abe, Y., Metz, S., et al. (2015) · Journal of the American Society of Echocardiography · doi:10.1016/j.echo.2014.11.003 · Cited by 1,580
Voigt, J.-U., Pedrizzetti, G., Lysyansky, P., Marwick, T. H., Houle, H., Baumann, R., Pedri, S., Ito, Y., Abe, Y., Metz, S., et al. (2015) · European Heart Journal - Cardiovascular Imaging · doi:10.1093/ehjci/jeu184 · Cited by 1,304
Metadata
- Authors
- Takigiku, K., Takeuchi, M., Izumi, C., Yuda, S., Sakata, K., Ohte, N., Tanabe, K., & Nakatani, S.
- Venue
- Circulation Journal
- Publisher
- Japanese Circulation Society
- Published
- 2012
- Volume
- 76
- Issue
- 11
- Pages
- 2623-2632
- ISSN
- 1346-9843 (ISSN-L)
- 1347-4820
- OpenAlex
- W1527833619
- Cited by
- 261
- References
- 19
- FWCI
- 12.85
- Type
- journal article
- Language
- en
- Open access
- bronze
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.