Student or educator? Sign up with your school email and get 6 months of Pro free.
Cited by 331

The DOI matches its Crossref record; 19 of the 19 references it cites were found in a registry or an index.

Experimental Validation of a New Ultrasound Method for the Simultaneous Assessment of Radial and Longitudinal Myocardial Deformation Independent of Insonation Angle

Open access
Langeland, Stian, D’hooge, Jan, Wouters, Patrick F., Leather, H. Alex, Claus, Piet, Bijnens, Bart, Sutherland, George R.·2005·Circulation

Abstract

Background— Strain and strain rate have been proposed as tools to quantify regional myocardial function. One of the major pitfalls of the current methodology is its angle dependency. To overcome this problem, we have developed a new method for the estimation of strain, independent of angle. The aim of this study was to validate this new methodology in an experimental setting using sonomicrometry. Methods and Results— In 5 open-chest sheep, ultrasound data were acquired. The new methodology was used to perform simultaneous measurements of radial and longitudinal strain in the inferolateral wall. Segment-length sonomicrometry crystals were used as the reference. After baseline acquisitions, deformation was modulated by pharmacologically changing the inotropic state of the myocardium and by inducing ischemia. Ultrasonically estimated radial and longitudinal strain were validated against sonomicrometry by means of Bland-Altman analysis and the intraclass correlation coefficient. For both strain components, good agreements were found between the ultrasound and the sonomicrometry measurements as shown by Bland-Altman statistics. The intraclass correlation coefficients were found to be 0.72 and 0.80 for the radial and longitudinal components, respectively. Conclusions— A new technique for the estimation of myocardial deformation was validated. It was shown that the current problem of angle dependency was solved and that 2 deformation components could be estimated simultaneously and accurately. Furthermore, the technique was less time-consuming, because anatomic tracking was performed automatically. This approach could potentially accelerate the clinical acceptance of ultrasound deformation imaging in cardiology.

Overview

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1161/circulationaha.105.554006

Cites

19 of 19 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 19 references

Cited by

See all 331

Metadata

Authors
Langeland, S., D’hooge, J., Wouters, P. F., Leather, H. A., Claus, P., Bijnens, B., & Sutherland, G. R.
Venue
Circulation
Published
2005-10-04
Volume
112
Issue
14
Pages
2157-2162
ISSN
  • 0009-7322 (ISSN-L)
  • 1524-4539
OpenAlex
W1978447366
Cited by
331
References
19
FWCI
15.27
Type
journal article
Language
en
Open access
bronze

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Experimental Validation of a New Ultrasound Method for the Simultaneous Assessment of Radial and Longitudinal Myocardial Deformation Independent of Insonation Angle. https://app.cochat.ai/papers/10.1161/circulationaha.105.554006
The paper
Langeland, S., D’hooge, J., Wouters, P. F., Leather, H. A., Claus, P., Bijnens, B., & Sutherland, G. R. (2005). Experimental Validation of a New Ultrasound Method for the Simultaneous Assessment of Radial and Longitudinal Myocardial Deformation Independent of Insonation Angle. Circulation. https://doi.org/10.1161/circulationaha.105.554006

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.