The DOI matches its Crossref record.
Deciphering Drift Time Measurements from Travelling Wave Ion Mobility Spectrometry-Mass Spectrometry Studies
Open accessAbstract
Detailed knowledge of the tertiary and quaternary structure of proteins and protein complexes is of immense importance in understanding their functionality. Similarly, variations in the conformational states of proteins form the underlying mechanisms behind many biomolecular processes, numerous of which are disease-related. Thus, the availability of reliable and accurate biophysical techniques that can provide detailed information concerning these issues is of paramount importance. Ion mobility spectrometry (IMS) coupled to mass spectrometry (MS) offers a unique opportunity to separate multi-component biomolecular entities and to measure the molecular mass and collision cross-section of individual components in a single, rapid (≤ 2 min) experiment, providing 3D-architectural information directly. Here we report a method of calibrating a commercially available electrospray ionisation (ESI)-travelling wave ion mobility spectrometry (TWIMS)–mass spectrometer using known cross-sectional areas determined for a range of biomolecules by conventional IMS-MS. Using this method of calibration, we have analysed a range of proteins of differing mass and 3D architecture in their native conformations by ESI-TWIMS-MS and found that the cross-sectional areas measured in this way compare extremely favourably with cross-sectional areas calculated using an in-house computing method based on Protein Data Bank NMR-derived co-ordinates. This not only provides a high degree of confidence in the calibration method, but also suggests that the gas phase ESI-TWIMS-MS measurements relate well to solution-based measurements derived from other biophysical techniques. In order to determine which instrumental parameters affect the ESI-TWIMS-MS cross-sectional area calibration, a systematic study of the parameters used to optimise TWIMS drift time separations has been carried out, observing the effect each parameter has on drift times and IMS resolution. Finally, the ESI-TWIMS-MS cross-sectional area calibration has been applied to the analysis of the amyloidogenic protein β 2-microglobulin and measurements for three co-populated conformational families, present under denaturing conditions, have been made: the folded, partially unfolded and unfolded states.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Recommendations for reporting ion mobility Mass Spectrometry measurements
Gabelica, V., Shvartsburg, A. A., Afonso, C., Barran, P., Benesch, J. L. P., Bleiholder, C., Bowers, M. T., Bilbao, A., Bush, M. F., Campbell, J. L., et al. (2019) · Mass Spectrometry Reviews · doi:10.1002/mas.21585 · Cited by 493
Self-citationIon mobility mass spectrometry of proteins and proteinassemblies
Uetrecht, C., Rose, R. J., van Duijn, E., Lorenzen, K., & Heck, A. J. R. (2010) · Chem. Soc. Rev. · doi:10.1039/b914002f · Cited by 462
Lapthorn, C., Pullen, F., & Chowdhry, B. Z. (2013) · Mass Spectrometry Reviews · doi:10.1002/mas.21349 · Cited by 398
Interrogating viral capsid assembly with ion mobility–mass spectrometry
Uetrecht, C., Barbu, I. M., Shoemaker, G. K., van Duijn, E., & Heck, A. J. R. (2011) · Nature Chemistry · doi:10.1038/nchem.947 · Cited by 267
Ion mobility in the pharmaceutical industry: an established biophysical technique or still niche?
Campuzano, I. D., & Lippens, J. L. (2018) · Current Opinion in Chemical Biology · doi:10.1016/j.cbpa.2017.11.008 · Cited by 42
Self-citation
Metadata
- Authors
- Smith, D. P., Knapman, T. W., Campuzano, I., Malham, R. W., Berryman, J. T., Radford, S. E., & Ashcroft, A. E.
- Venue
- European Journal of Mass Spectrometry
- Publisher
- SAGE Publications
- Published
- 2009-04
- Volume
- 15
- Issue
- 2
- Pages
- 113-130
- ISSN
- 1356-1049 (ISSN-L)
- 1469-0667
- 1751-6838
- OpenAlex
- W1988308498
- Cited by
- 334
- References
- 0
- FWCI
- 12.44
- Type
- journal article
- Language
- en
- Open access
- bronze
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Deciphering Drift Time Measurements from Travelling Wave Ion Mobility Spectrometry-Mass Spectrometry Studies. https://app.cochat.ai/papers/10.1255/ejms.947
- The paper
- Smith, D. P., Knapman, T. W., Campuzano, I., Malham, R. W., Berryman, J. T., Radford, S. E., & Ashcroft, A. E. (2009). Deciphering Drift Time Measurements from Travelling Wave Ion Mobility Spectrometry-Mass Spectrometry Studies. European Journal of Mass Spectrometry. https://doi.org/10.1255/ejms.947
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.