Hyperspectral Imaging: A Review of Best Practice, Performance and Pitfalls for in-line and on-line Applications
The DOI matches its Crossref record; 62 of the 62 references it cites were found in a registry or an index.
Abstract
The objective of this paper is to provide a comprehensive review of best practice in hyperspectral imaging. The paper starts to review the taxonomy of the different spectral imaging techniques together with their advantages and disadvantages. The appropriate selection of cameras and spectrographs and their figures of merit are discussed and a detailed description is given of how to qualify and calibrate a pushbroom imaging system for on-line and in-line control. Special emphasis is given to detection and avoidance of specular reflection which can severely distort quantification of the spectral response. Recommendations for an ideal Lambertian illumination are given and the effects of scatter and absorption are discussed when particulate systems are investigated. Here, first principles are introduced and strategies for how to separate scatter from absorption are developed. A simple method using the Kubelka and Munk approach is examined and separated scatter and pure absorption spectra are shown. The same procedure is applied to show the lateral distribution of the separated scatter and absorption properties of an active pharmaceutical ingredient embedded in an excipient. The terms penetration and information depth are discussed and an example of penetration depth profile over wavelengths is provided. Based on a good quality optical set-up and a validated measurement procedure, a practical procedure is described to analyse the data cube using the chemometrics toolbox for hyperspectral imaging. Finally, a survey on selected applications demonstrates the future potential of hyperspectral imaging.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Chandrasekhar, S. (1950) · CERN Document Server (European Organization for Nuclear Research) · Cited by 8,702
Communication in the presence of noise
Shannon, C. E. (1949) · Proceedings of the IRE · doi:10.1109/jrproc.1949.232969 · Cited by 6,539
Ein Beitrag zur Optik der Farban striche
Kubelka, P. (1931) · Medical Entomology and Zoology · Cited by 4,654
Standard Normal Variate Transformation and De-Trending of Near-Infrared Diffuse Reflectance Spectra
Barnes, R. J., Dhanoa, M. S., & Lister, S. J. (1989) · Applied Spectroscopy · doi:10.1366/0003702894202201 · Cited by 3,867
New Contributions to the Optics of Intensely Light-Scattering Materials Part I
Kubelka, P. (1948) · Journal of the Optical Society of America · doi:10.1364/josa.38.000448 · Cited by 2,681
Introduction to remote sensing
Campbell, J. B. (1987) · Geocarto International · doi:10.1080/10106048709354126 · Cited by 2,292
Linearization and Scatter-Correction for Near-Infrared Reflectance Spectra of Meat
Geladi, P., MacDougall, D., & Martens, H. (1985) · Applied Spectroscopy · doi:10.1366/0003702854248656 · Cited by 1,513
Kortüm, G. (1969) · Springer eBooks · doi:10.1007/978-3-642-88071-1 · Cited by 1,429
Farrell, T. J., Patterson, M. S., & Wilson, B. (1992) · Medical Physics · doi:10.1118/1.596777 · Cited by 1,378
Jaumot, J., Gargallo, R., de Juan, A., & Tauler, R. (2005) · Chemometrics and Intelligent Laboratory Systems · doi:10.1016/j.chemolab.2004.12.007 · Cited by 1,148
Cited by
Manley, M. (2014) · Chem. Soc. Rev. · doi:10.1039/c4cs00062e · Cited by 973
Hyperspectral image analysis. A tutorial
Amigo, J. M., Babamoradi, H., & Elcoroaristizabal, S. (2015) · Analytica Chimica Acta · doi:10.1016/j.aca.2015.09.030 · Cited by 379
Hyperspectral imaging and its applications: A review
Bhargava, A., Sachdeva, A., Sharma, K., Alsharif, M. H., Uthansakul, P., & Uthansakul, M. (2024) · Heliyon · doi:10.1016/j.heliyon.2024.e33208 · Cited by 277
Metadata
- Authors
- Boldrini, B., Kessler, W., Rebner, K., & Kessler, R. W.
- Venue
- Journal of Near Infrared Spectroscopy
- Publisher
- SAGE Publications
- Published
- 2012-01-01
- Volume
- 20
- Issue
- 5
- Pages
- 483-508
- ISSN
- 0967-0335 (ISSN-L)
- 1751-6552
- OpenAlex
- W1996821078
- Cited by
- 192
- References
- 62
- FWCI
- 4.53
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Hyperspectral Imaging: A Review of Best Practice, Performance and Pitfalls for in-line and on-line Applications. https://app.cochat.ai/papers/10.1255/jnirs.1003
- The paper
- Boldrini, B., Kessler, W., Rebner, K., & Kessler, R. W. (2012). Hyperspectral Imaging: A Review of Best Practice, Performance and Pitfalls for in-line and on-line Applications. Journal of Near Infrared Spectroscopy. https://doi.org/10.1255/jnirs.1003
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.