The DOI matches its Crossref record; 1 of the 1 references it cites were found in a registry or an index.
Linearization and Scatter-Correction for Near-Infrared Reflectance Spectra of Meat
Abstract
This paper is concerned with the quantitative analysis of multicomponent mixtures by diffuse reflectance spectroscopy. Near-infrared reflectance (NIRR) measurements are related to chemical composition but in a nonlinear way, and light scatter distorts the data. Various response linearizations of reflectance (R) are compared ( R with Saunderson correction for internal reflectance, log 1/ R, and Kubelka-Munk transformations and its inverse). A multi-wavelength concept for optical correction (Multiplicative Scatter Correction, MSC) is proposed for separating the chemical light absorption from the physical light scatter. Partial Least Squares (PLS) regression is used as the multivariate linear calibration method for predicting fat in meat from linearized and scatter-corrected NIRR data over a broad concentration range. All the response linearization methods improved fat prediction when used with the MSC; corrected log 1/ R and inverse Kubelka-Munk transformations yielded the best results. The MSC provided simpler calibration models with good correspondence to the expected physical model of meat. The scatter coefficients obtained from the MSC correlated with fat content, indicating that fat affects the NIRR of meat with an additive absorption component and a multiplicative scatter component.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
The multivariate calibration problem in chemistry solved by the PLS method
Wold, S., Martens, H., & Wold, H. (1983) · Lecture notes in mathematics · doi:10.1007/bfb0062108 · Cited by 1,185
Self-citation
Cited by
Visible and near infrared spectroscopy in soil science
Stenberg, B., Viscarra Rossel, R. A., Mouazen, A. M., & Wetterlind, J. (2010) · Advances in Agronomy · doi:10.1016/s0065-2113(10)07005-7 · Cited by 1,549
NIR spectroscopy: a rapid-response analytical tool
Blanco, M., & Villarroya, I. (2002) · TrAC Trends in Analytical Chemistry · doi:10.1016/s0165-9936(02)00404-1 · Cited by 874
Review of multidimensional data processing approaches for Raman and infrared spectroscopy
Gautam, R., Vanga, S., Ariese, F., & Umapathy, S. (2015) · EPJ Techniques and Instrumentation · doi:10.1140/epjti/s40485-015-0018-6 · Cited by 696
Transfer of multivariate calibration models: a review
Feudale, R. N., Woody, N. A., Tan, H., Myles, A. J., Brown, S. D., & Ferré, J. (2002) · Chemometrics and Intelligent Laboratory Systems · doi:10.1016/s0169-7439(02)00085-0 · Cited by 555
Martens, H., & Stark, E. (1991) · Journal of Pharmaceutical and Biomedical Analysis · doi:10.1016/0731-7085(91)80188-f · Cited by 515
Self-citation
Metadata
- Authors
- Geladi, P., MacDougall, D., & Martens, H.
- Venue
- Applied Spectroscopy
- Publisher
- SAGE Publications
- Published
- 1985-05
- Volume
- 39
- Issue
- 3
- Pages
- 491-500
- ISSN
- 0003-7028 (ISSN-L)
- 1943-3530
- OpenAlex
- W2045125597
- Cited by
- 1,513
- References
- 1
- FWCI
- 10.44
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Linearization and Scatter-Correction for Near-Infrared Reflectance Spectra of Meat. https://app.cochat.ai/papers/10.1366/0003702854248656
- The paper
- Geladi, P., MacDougall, D., & Martens, H. (1985). Linearization and Scatter-Correction for Near-Infrared Reflectance Spectra of Meat. Applied Spectroscopy. https://doi.org/10.1366/0003702854248656
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.