Measurement of urinary free cortisol using liquid chromatography-tandem mass spectrometry: comparison with the urine adapted ACS:180 serum cortisol chemiluminescent immunoassay and development of a new reference range
The DOI matches its Crossref record; 3 of the 3 references it cites were found in a registry or an index.
Abstract
Background: The measurement of urinary free cortisol (UFC) is commonly used in the investigation of possible Cushing's syndrome. With the recent availability of liquid chromatography-tandem mass spectrometry (LC-MS/MS) in hospital laboratories, we wanted to develop a specific UFC LC-MS/MS method and compare it with our current immunoassay method and develop a new LC-MS/MS reference range if required. Methods: A UFC LC-MS/MS method using deuterated cortisol as an internal standard was optimized using solid-phase extraction as a clean-up procedure. The multiple reaction-monitoring transitions used for the detection of cortisol and deuterated cortisol were 363.1>121 and 365.1>121.8, respectively. The method was investigated regarding precision, linearity, sensitivity, recovery and interference. UFC was measured by the in-house urine adapted ACS:180 serum cortisol immunoassay and the developed LC-MS/MS method in 110 urine samples from patients being investigated for possible Cushing's syndrome. Results: The within-batch precisions ( n=25) of the LC-MS/MS method were 7.6%, 4.5% and 3.3% at 25.0 nmol/L, 49.6 nmol/L and 344.6 nmol/L, respectively; the between-batch precisions ( n = 10) were 9.4%, 9.4% and 8.4%, respectively, at these concentrations. The method is sensitive down to 5 nmol/L and linear up to at least 1000 nmol/L. The method showed adequate cortisol recovery and no interference from the numerous drugs and steroids tested. The total run time for 20 samples, including sample preparation, was 120 min. A scatter plot of paired UFC measurements on the LC-MS/MS and the ACS:180 gave the equation: LC-MS/MS=0.408 (ACS:180)+2.65, r 2 = 0.6664. The 24-h measured UFC results on 110 samples (25 men and 85 women) were positively skewed. After log transformation the data were less skewed, and following back transformation of the lower 97.5th centile, the upper limit of normal was 165 nmol/24 h. The 95th centile of the untransformed data was 146 nmol/24 h ( n=110, 25 men and 85 women). Separated by sex, the 95th centile was 152 nmol/24 h for men ( n=25) and 141 nmol/24 h for women ( n=85). Conclusions: We have developed a UFC LC-MS/MS method with a solid-phase extraction clean-up step. The method shows adequate performance and is suitable for routine laboratory use. The mixed sex ( n=110, men=25, women=85) reference range was up to 165 nmol/24 h or 146 nmol/24 h, depending on how the data are manipulated.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
STATISTICAL METHODS FOR ASSESSING AGREEMENT BETWEEN TWO METHODS OF CLINICAL MEASUREMENT
Martin Bland, J., & Altman, D. (1986) · The Lancet · doi:10.1016/s0140-6736(86)90837-8 · Cited by 47,965
Passing, H., & Bablok, W. (1983) · cclm · doi:10.1515/cclm.1983.21.11.709 · Cited by 1,513
Cushing's syndrome: a review of diagnostic tests.
Crapo, L. (1979) · Metabolism · doi:10.1016/0026-0495(79)90097-0 · Cited by 393
Cited by
Nicolson, N. A. (2008) · Handbook of Physiological Research Methods in Health Psychology · doi:10.4135/9781412976244.n3 · Cited by 268
Determination of cortisol in serum, saliva and urine
Turpeinen, U., & Hämäläinen, E. (2013) · Best Practice & Research Clinical Endocrinology & Metabolism · doi:10.1016/j.beem.2013.10.008 · Cited by 214
Eisenhofer, G., Peitzsch, M., Kaden, D., Langton, K., Pamporaki, C., Masjkur, J., Tsatsaronis, G., Mangelis, A., Williams, T. A., Reincke, M., et al. (2017) · Clinica Chimica Acta · doi:10.1016/j.cca.2017.05.002 · Cited by 171
Validation of salivary oxytocin and vasopressin as biomarkers in domestic dogs
MacLean, E. L., Gesquiere, L. R., Gee, N., Levy, K., Martin, W. L., & Carter, C. S. (2018) · Journal of Neuroscience Methods · doi:10.1016/j.jneumeth.2017.08.033 · Cited by 117
Cortisol measurements in Cushing’s syndrome: immunoassay or mass spectrometry?
Casals, G., & Hanzu, F. A. (2020) · Annals of Laboratory Medicine · doi:10.3343/alm.2020.40.4.285 · Cited by 80
Metadata
- Authors
- McCann, S. J., Gillingwater, S., & Keevil, B. G.
- Venue
- Annals of Clinical Biochemistry: International Journal of Laboratory Medicine
- Publisher
- SAGE Publications
- Published
- 2005-03-01
- Volume
- 42
- Issue
- 2
- Pages
- 112-118
- ISSN
- 0004-5632 (ISSN-L)
- 1758-1001
- OpenAlex
- W2060514637
- Cited by
- 43
- References
- 3
- FWCI
- 0.91
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Measurement of urinary free cortisol using liquid chromatography-tandem mass spectrometry: comparison with the urine adapted ACS:180 serum cortisol chemiluminescent immunoassay and development of a new reference range. https://app.cochat.ai/papers/10.1258/0004563053492775
- The paper
- McCann, S. J., Gillingwater, S., & Keevil, B. G. (2005). Measurement of urinary free cortisol using liquid chromatography-tandem mass spectrometry: comparison with the urine adapted ACS:180 serum cortisol chemiluminescent immunoassay and development of a new reference range. Annals of Clinical Biochemistry: International Journal of Laboratory Medicine. https://doi.org/10.1258/0004563053492775
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.