A prospective study of causes of haemolysis during venepuncture: tourniquet time should be kept to a minimum
The DOI matches its Crossref record; 1 of the 1 references it cites were found in a registry or an index.
Abstract
Background: Haemolysis is defined as the release of cellular components of erythrocytes and other blood cells into the extracellular space of blood. These cellular components can cause interference in laboratory measurements, potassium being a commonly measured analyte to be affected. A number of factors have been implicated in the aetiology of haemolysis. We undertook this study to enable us to identify and hence rectify causes of haemolysis in samples from patients on acute medical and surgical wards. Methods: We performed a prospective study of 353 blood sampling events during February and March 2007. A proforma was used to obtain detailed information of each blood-taking episode. Information from the proforma was linked to the incidence of haemolysis obtained from the hospital computer system. Results: The incidence of haemolysis among the samples studied was 6.5%. While staff group, method of sampling, tourniquet time and number of attempts at venepuncture were each univariately associated with haemolysis, stepwise logistic regression resulted in a final model which only included tourniquet time (odds ratio for haemolysis if tourniquet time >1 min was 19.5 [95% confidence interval [CI] 5.6–67.4%]). Conclusion: Tourniquet time of more than a minute is associated with a significant increase in risk of haemolysis. Advice on tourniquet time is included in phlebotomy training within the hospital; hence a campaign of appropriately channelled continuing education on this issue may be successful in reducing the haemolysis rate.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Pseudohyperkalemia Caused by Fist Clenching during Phlebotomy
Don, B. R., Sebastian, A., Cheitlin, M., Christiansen, M., & Schambelan, M. (1990) · New England Journal of Medicine · doi:10.1056/nejm199005033221806 · Cited by 132
Cited by
Variation in phlebotomy techniques in emergency medicine and the incidence of haemolysed samples
Berg, J. E., Ahee, P., & Berg, J. D. (2011) · Annals of Clinical Biochemistry: International Journal of Laboratory Medicine · doi:10.1258/acb.2011.011099 · Cited by 39
Mrazek, C., Simundic, A.-M., Wiedemann, H., Krahmer, F., Felder, T. K., Kipman, U., Hoppe, U., Haschke-Becher, E., & Cadamuro, J. (2017) · Clinical Chemistry and Laboratory Medicine (CCLM) · doi:10.1515/cclm-2016-0940 · Cited by 24
Twibell, K. R., Hofstetter, P., Siela, D., Brown, D., & Jones, H. M. (2019) · Journal of Infusion Nursing · doi:10.1097/nan.0000000000000338 · Cited by 8
Metadata
- Authors
- Saleem, S., Mani, V, Chadwick, M. A., Creanor, S., & Ayling, R. M.
- Venue
- Annals of Clinical Biochemistry: International Journal of Laboratory Medicine
- Publisher
- SAGE Publications
- Published
- 2009-04-23
- Volume
- 46
- Issue
- 3
- Pages
- 244-246
- ISSN
- 0004-5632 (ISSN-L)
- 1758-1001
- OpenAlex
- W2026866098
- Cited by
- 52
- References
- 1
- FWCI
- 1.18
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: A prospective study of causes of haemolysis during venepuncture: tourniquet time should be kept to a minimum. https://app.cochat.ai/papers/10.1258/acb.2009.008228
- The paper
- Saleem, S., Mani, V, Chadwick, M. A., Creanor, S., & Ayling, R. M. (2009). A prospective study of causes of haemolysis during venepuncture: tourniquet time should be kept to a minimum. Annals of Clinical Biochemistry: International Journal of Laboratory Medicine. https://doi.org/10.1258/acb.2009.008228
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.