The DOI matches its Crossref record; 70 of the 70 references it cites were found in a registry or an index.
The detection and prevention of errors in laboratory medicine
Open accessAbstract
The last few decades have seen a significant decrease in the rates of analytical errors in clinical laboratories. Evidence demonstrates that pre- and post-analytical steps of the total testing process (TTP) are more error-prone than the analytical phase. Most errors are identified in pre-pre-analytic and post-post-analytic steps outside of the laboratory. In a patient-centred approach to the delivery of health-care services, there is the need to investigate, in the TTP, any possible defect that may have a negative impact on the patient. In the interests of patients, any direct or indirect negative consequence related to a laboratory test must be considered, irrespective of which step is involved and whether the error depends on a laboratory professional (e.g. calibration/testing error) or non-laboratory operator (e.g. inappropriate test request, error in patient identification and/or blood collection). Patient misidentification and problems communicating results, which affect the delivery of diagnostic services, are recognized as the main goals for quality improvement. International initiatives aim at improving these aspects. Grading laboratory errors on the basis of their seriousness should help identify priorities for quality improvement and encourage a focus on corrective/preventive actions. It is important to consider not only the actual patient harm sustained but also the potential worst-case outcome if such an error were to reoccur. The most important lessons we have learned are that system theory also applies to laboratory testing and that errors and injuries can be prevented by redesigning systems that render it difficult for all health-care professionals to make mistakes.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
To Err Is Human: Building a Safer Health System
(2000) · National Academies Press eBooks · doi:10.17226/9728 · Cited by 14,044
Human error: models and management
Reason, J. (2000) · BMJ · doi:10.1136/bmj.320.7237.768 · Cited by 5,665
Reason, J. (1990) · doi:10.1017/cbo9781139062367 · Cited by 5,108
Diagnostic error in internal medicine
Graber, M. L., Franklin, N., & Gordon, R. (2005) · Archives of Internal Medicine · doi:10.1001/archinte.165.13.1493 · Cited by 1,549
From the Joint Commission on Accreditation of Healthcare Organizations
Loeb, J. M. (1996) · JAMA · doi:10.1001/jama.275.7.508 · Cited by 1,534
To err is human. Building a safer health system
Marano, C., Murianni, L., & Sticchi, L. (2005) · Italian Journal of Public Health · doi:10.2427/5972 · Cited by 1,271
Bonini, P., Plebani, M., Ceriotti, F., & Rubboli, F. (2002) · Clinical Chemistry · doi:10.1093/clinchem/48.5.691 · Cited by 850
Self-citationLeape, L. L. (2002) · New England Journal of Medicine · doi:10.1056/nejmnejmhpr011493 · Cited by 831
Errors in clinical laboratories or errors in laboratory medicine?
Plebani, M. (2006) · Clinical Chemistry and Laboratory Medicine (CCLM) · doi:10.1515/cclm.2006.123 · Cited by 734
Self-citationErrors in a Stat Laboratory: Types and Frequencies 10 Years Later
Carraro, P., & Plebani, M. (2007) · Clinical Chemistry · doi:10.1373/clinchem.2007.088344 · Cited by 670
Self-citationMissed and delayed diagnoses in the ambulatory setting: a study of closed malpractice claims
Gandhi, T. K., Kachalia, A., Thomas, E. J., Puopolo, A. L., Yoon, C., Brennan, T. A., & Studdert, D. M. (2006) · Annals of Internal Medicine · doi:10.7326/0003-4819-145-7-200610030-00006 · Cited by 662
Mistakes in a stat laboratory: types and frequency
Plebani, M., & Carraro, P. (1997) · Clinical Chemistry · doi:10.1093/clinchem/43.8.1348 · Cited by 572
Self-citationTate, J. R., & Ward, G. (2004) · PubMed · Cited by 548
Kachalia, A., Gandhi, T. K., Puopolo, A. L., Yoon, C., Thomas, E. J., Griffey, R., Brennan, T. A., & Studdert, D. M. (2007) · Annals of Emergency Medicine · doi:10.1016/j.annemergmed.2006.06.035 · Cited by 497
Haemolysis: an overview of the leading cause of unsuitable specimens in clinical laboratories
Lippi, G., Blanckaert, N., Bonini, P., Green, S., Kitchen, S., Palicka, V., Vassault, A. J., & Plebani, M. (2008) · Clinical Chemistry and Laboratory Medicine · doi:10.1515/cclm.2008.170 · Cited by 466
Self-citationPreanalytical variability: the dark side of the moon in laboratory testing
Lippi, G., Guidi, G. C., Mattiuzzi, C., & Plebani, M. (2006) · Clinical Chemistry and Laboratory Medicine (CCLM) · doi:10.1515/cclm.2006.073 · Cited by 415
Self-citationPatient Safety Concerns Arising from Test Results That Return after Hospital Discharge
Roy, C. L., Poon, E. G., Karson, A. S., Ladak-Merchant, Z., Johnson, R. E., Maviglia, S. M., & Gandhi, T. K. (2005) · Annals of Internal Medicine · doi:10.7326/0003-4819-143-2-200507190-00011 · Cited by 397
Exploring the iceberg of errors in laboratory medicine
Plebani, M. (2009) · Clinica Chimica Acta · doi:10.1016/j.cca.2009.03.022 · Cited by 289
Self-citationFMEA: A model for reducing medical errors
Chiozza, M. L., & Ponzetti, C. (2009) · Clinica Chimica Acta · doi:10.1016/j.cca.2009.03.015 · Cited by 270
Problem Doctors: Is There a System-Level Solution?
Leape, L. L., & Fromson, J. A. (2006) · Annals of Internal Medicine · doi:10.7326/0003-4819-144-2-200601170-00008 · Cited by 260
Acting on Significant Laboratory Results
Lundberg, G. D. (1981) · JAMA: The Journal of the American Medical Association · doi:10.1001/jama.1981.03310420052033 · Cited by 229
Leape, L. L. (2009) · Clinica Chimica Acta · doi:10.1016/j.cca.2009.03.020 · Cited by 220
Errors in Laboratory Medicine: Practical Lessons to Improve Patient Safety
Howanitz, P. J. (2005) · Archives of Pathology & Laboratory Medicine · doi:10.5858/2005-129-1252-eilmpl · Cited by 218
The Quality of Laboratory Testing Today
Westgard, J. O., & Westgard, S. A. (2006) · American Journal of Clinical Pathology · doi:10.1309/v50h4frvvwx12c79 · Cited by 190
Errors in laboratory medicine and patient safety: the road ahead
Plebani, M. (2007) · Clinical Chemistry and Laboratory Medicine (CCLM) · doi:10.1515/cclm.2007.170 · Cited by 184
Self-citationA Survey of the Accuracy of Chemical Analyses in Clinical Laboratories
Belk, W. P., & Sunderman, F. W. (1947) · American Journal of Clinical Pathology · doi:10.1093/ajcp/17.11.853 · Cited by 180
Risk management in the preanalytical phase of laboratory testing
Lippi, G., & Guidi, G. C. (2007) · Clinical Chemical Laboratory Medicine · doi:10.1515/cclm.2007.167 · Cited by 176
Medical errors: impact on clinical laboratories and other critical areas
Kalra, J. (2004) · Clinical Biochemistry · doi:10.1016/j.clinbiochem.2004.08.009 · Cited by 168
Laposata, M., & Dighe, A. (2007) · Clinical Chemical Laboratory Medicine · doi:10.1515/cclm.2007.173 · Cited by 162
Pre-analytical workstations: A tool for reducing laboratory errors
Da Rin, G. (2009) · Clinica Chimica Acta · doi:10.1016/j.cca.2009.03.024 · Cited by 161
The IFCC Working Group on laboratory errors and patient safety
Sciacovelli, L., & Plebani, M. (2009) · Clinica Chimica Acta · doi:10.1016/j.cca.2009.03.025 · Cited by 161
Self-citationFrequency of Failure to Inform Patients of Clinically Significant Outpatient Test Results
Casalino, L. P., Dunham, D., Chin, M. H., Bielang, R., Kistner, E. O., Karrison, T. G., Ong, M. K., Sarkar, U., McLaughlin, M. A., & Meltzer, D. O. (2009) · Archives of Internal Medicine · doi:10.1001/archinternmed.2009.130 · Cited by 159
Hickner, J., Graham, D. G., Elder, N. C., Brandt, E., Emsermann, C. B., Dovey, S., & Phillips, R. (2008) · Quality and Safety in Health Care · doi:10.1136/qshc.2006.021915 · Cited by 158
Classifying Laboratory Incident Reports to Identify Problems That Jeopardize Patient Safety
Shojania, K. G., Hamill, T. R., Kim, P. S., Ng, M. V. L., & Astion, M. L. (2003) · American Journal of Clinical Pathology · doi:10.1309/8u5d0ma6mfh2fg19 · Cited by 155
Wahls, T. L., & Cram, P. M. (2007) · BMC Family Practice · doi:10.1186/1471-2296-8-32 · Cited by 133
Laboratory network of excellence: enhancing patient safety and service effectiveness
Plebani, M., Ceriotti, F., Messeri, G., Ottomano, C., Pansini, N., & Bonini, P. A. (2006) · Clinical Chemistry and Laboratory Medicine (CCLM) · doi:10.1515/cclm.2006.028 · Cited by 124
Self-citationRecommendations for detection and management of unsuitable samples in clinical laboratories
Lippi, G., Banfi, G., Buttarello, M., Ceriotti, F., Daves, M., Dolci, A., Caputo, M., Giavarina, D., Montagnana, M., Miconi, V., et al. (2007) · Clinical Chemistry and Laboratory Medicine (CCLM) · doi:10.1515/cclm.2007.174 · Cited by 120
Meier, F. A., & Jones, B. A. (2005) · Archives of Pathology & Laboratory Medicine · doi:10.5858/2005-129-1262-ptesaa · Cited by 116
Westgard, J. O., & Westgard, S. A. (2006) · PubMed · Cited by 114
Errors, mistakes, blunders, outliers, or unacceptable results: how many?
Witte, D. L., VanNess, S. A., Angstadt, D. S., & Pennell, B. J. (1997) · Clinical Chemistry · doi:10.1093/clinchem/43.8.1352 · Cited by 112
The Need for an Outcomes Research Agenda for Clinical Laboratory Testing
Lundberg, G. D. (1998) · JAMA · doi:10.1001/jama.280.6.565 · Cited by 107
Evaluation of Effectiveness of a Computerized Notification System for Reporting Critical Values
Piva, E., Sciacovelli, L., Zaninotto, M., Laposata, M., & Plebani, M. (2009) · American Journal of Clinical Pathology · doi:10.1309/ajcpys80bucbxtuh · Cited by 101
Self-citationProblems in Laboratory Testing in Primary Care
Nutting, P. A. (1996) · JAMA · doi:10.1001/jama.1996.03530320059035 · Cited by 100
Does POCT reduce the risk of error in laboratory testing?
Plebani, M. (2009) · Clinica Chimica Acta · doi:10.1016/j.cca.2009.03.014 · Cited by 97
Self-citationApplication of the Six Sigma concept in clinical laboratories: a review
Gras, J. M., & Philippe, M. (2007) · Clinical Chemistry and Laboratory Medicine (CCLM) · doi:10.1515/cclm.2007.135 · Cited by 84
Keeping the Patient in the Equation — Humanism and Health Care Reform
Hartzband, P., & Groopman, J. E. (2009) · New England Journal of Medicine · doi:10.1056/nejmp0904813 · Cited by 83
Interpretative commenting: A tool for improving the laboratory–clinical interface
Plebani, M. (2009) · Clinica Chimica Acta · doi:10.1016/j.cca.2009.03.012 · Cited by 83
Self-citationInterference from endogenous antibodies in automated immunoassays: what laboratorians need to know
Ismail, A. A. (2009) · Journal of Clinical Pathology · doi:10.1136/jcp.2008.055848 · Cited by 82
Stroobants, A. K., Goldschmidt, H. M. J., & Plebani, M. (2003) · Clinica Chimica Acta · doi:10.1016/s0009-8981(03)00181-5 · Cited by 78
Self-citationError rates in Australian chemical pathology laboratories
Khoury, M., Burnett, L., & Mackay, M. A. (1996) · The Medical Journal of Australia · doi:10.5694/j.1326-5377.1996.tb124883.x · Cited by 72
Lapworth, R., & Teal, T. K. (1994) · Annals of Clinical Biochemistry International Journal of Laboratory Medicine · doi:10.1177/000456329403100113 · Cited by 65
A Public Health Approach to Reducing Error
Gostin, L. O. (2000) · JAMA · doi:10.1001/jama.283.13.1742 · Cited by 61
The reporting, classification and grading of quality failures in the medical laboratory
Kane, M. O. (2009) · Clinica Chimica Acta · doi:10.1016/j.cca.2009.03.023 · Cited by 61
Factitious Biochemical Measurements Resulting From Hematologic Conditions
Dalal, B. I., & Brigden, M. L. (2009) · American Journal of Clinical Pathology · doi:10.1309/ajcpy9rp5qytyfwc · Cited by 57
Point of care testing in Critical Care Medicine: the clinician's view
Drenck, N.-E. (2001) · Clinica Chimica Acta · doi:10.1016/s0009-8981(01)00448-x · Cited by 56
Interpretative reports and critical values
Piva, E., & Plebani, M. (2009) · Clinica Chimica Acta · doi:10.1016/j.cca.2009.03.028 · Cited by 55
Self-citationSchiff, G. D., Aggarwal, H. C., Kumar, S., & Mcnutt, R. (2000) · The American Journal of Medicine · doi:10.1016/s0002-9343(00)00546-5 · Cited by 52
Evaluation of LabRespond, a New Automated Validation System for Clinical Laboratory Test Results
Oosterhuis, W. P., Ulenkate, H. J. L. M., & Goldschmidt, H. M. J. (2000) · Clinical Chemistry · doi:10.1093/clinchem/46.11.1811 · Cited by 51
Defining the best quality-control systems by design and inspection
Hinckley, C. M. (1997) · Clinical Chemistry · doi:10.1093/clinchem/43.5.873 · Cited by 50
Missed hypothyroidism diagnosis uncovered by linking laboratory and pharmacy data
Schiff, G. D. (2005) · Archives of Internal Medicine · doi:10.1001/archinte.165.5.574 · Cited by 47
Steindel, S. J., Howanitz, P. J., & Renner, S. W. (1996) · PubMed · Cited by 41
Post-analytical errors with portable glucose meters in the hospital setting
Carraro, P., & Plebani, M. (2009) · Clinica Chimica Acta · doi:10.1016/j.cca.2009.03.013 · Cited by 37
Self-citationO’Kane, M., Lynch, P. L. M., & McGowan, N. (2008) · Annals of Clinical Biochemistry International Journal of Laboratory Medicine · doi:10.1258/acb.2007.007097 · Cited by 28
Process and risk analysis to reduce errors in clinical laboratories
Signori, C., Ceriotti, F., Sanna, A., Plebani, M., Messeri, G., Ottomano, C., Serio, F. D., & Bonini, P. A. (2007) · Clinical Chemistry and Laboratory Medicine (CCLM) · doi:10.1515/cclm.2007.172 · Cited by 26
Self-citationPatient safety in point-of-care testing
Jones, B. A., & Meier, F. A. (2004) · Clinics in Laboratory Medicine · doi:10.1016/j.cll.2004.06.001 · Cited by 24
Is it safe to have a laboratory test?
Boone, D. J. (2004) · Accreditation and Quality Assurance · doi:10.1007/s00769-004-0855-5 · Cited by 23
Types of error within a clinical laboratory.
McSwiney, R. R., & Woodrow, D. A. (1969) · PubMed · Cited by 22
Preventing Problems, Medical Errors, and Biohazards in Point-of-Care Testing
Kost, G. J. (2003) · Point of Care The Journal of Near-Patient Testing & Technology · doi:10.1097/00134384-200306000-00002 · Cited by 20
The role of in vitro diagnostic companies in reducing laboratory error
Stanković, A. K., & Romeo, P. J. (2007) · Clinical Chemistry and Laboratory Medicine (CCLM) · doi:10.1515/cclm.2007.175 · Cited by 19
The Physician and the Laboratory
Graber, M. L. (2006) · Pathology Patterns Reviews · doi:10.1309/54xr770u8wtegg1h · Cited by 16
Cited by
Photonic crystals: emerging biosensors and their promise for point-of-care applications
Inan, H., Poyraz, M., Inci, F., Lifson, M. A., Baday, M., Cunningham, B. T., & Demirci, U. (2017) · Chemical Society Reviews · doi:10.1039/c6cs00206d · Cited by 480
The Value of In Vitro Diagnostic Testing in Medical Practice: A Status Report
Rohr, U.-P., Binder, C., Dieterle, T., Giusti, F., Messina, C. G. M., Toerien, E., Moch, H., & Schäfer, H. H. (2016) · PLOS ONE · doi:10.1371/journal.pone.0149856 · Cited by 229
The challenge of diagnostic metagenomics
Greninger, A. L. (2018) · Expert Review of Molecular Diagnostics · doi:10.1080/14737159.2018.1487292 · Cited by 156
Preanalytical considerations in blood gas analysis
Baird, G. (2013) · Biochemia Medica · doi:10.11613/bm.2013.005 · Cited by 90
“Errors in the phases of laboratory testing, from (8).”
BackgroundPerformance specifications for the extra-analytical phases of laboratory testing: Why and how
Plebani, M. (2017) · Clinical Biochemistry · doi:10.1016/j.clinbiochem.2017.02.002 · Cited by 34
Self-citation
Metadata
- Authors
- Plebani, M.
- Venue
- Annals of Clinical Biochemistry: International Journal of Laboratory Medicine
- Publisher
- SAGE Publications
- Published
- 2009-12-01
- Volume
- 47
- Issue
- 2
- Pages
- 101-110
- ISSN
- 0004-5632 (ISSN-L)
- 1758-1001
- OpenAlex
- W1969393223
- Cited by
- 479
- References
- 70
- FWCI
- 10.63
- Type
- journal article
- Language
- en
- Open access
- bronze
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.