Cited by 111Clinical Laboratory Practices and Quality ControlAdrenal Hormones and DisordersStress Responses and Cortisol

Comparison of serum cortisol measurement by immunoassay and liquid chromatography-tandem mass spectrometry in patients receiving the 11 β -hydroxylase inhibitor metyrapone

Monaghan, Phillip J, Owen, Laura J, Trainer, Peter J, Brabant, Georg, Keevil, Brian G, Darby, Denise·2011·Annals of Clinical Biochemistry International Journal of Laboratory Medicine

Abstract

BACKGROUND: The accurate measurement of cortisol by immunoassay is compromised by the potential for cross-reactivity of reagent antibodies with structurally related steroids present in serum. This susceptibility is potentiated when normal steroid metabolism is altered pharmaceutically by antisteroidogenic drugs utilized in the management of Cushing's syndrome to moderate cortisol production. The clinical implications of falsely elevated cortisol results include over-treatment and unrecognized hypoadrenalism. To investigate the effect of the 11β-hydroxylase inhibitor metyrapone on serum cortisol assay, a comparison of measurement by immunoassay versus liquid chromatography-tandem mass spectrometry (LC-MS/MS) was conducted. METHODS: Cortisol was measured in serum from three patient groups: (1) patients receiving metyrapone (n = 112 samples from 10 patients); (2) control group of patients diagnosed with Cushing's syndrome currently receiving no treatment (n = 31); and (3) control group of patients with no adrenal pathology and not receiving medication known to interfere in cortisol immunoassay (n = 67). RESULTS: Bland-Altman plots showed agreement between methods for the control group (bias = 1.1% [-4.3 nmol/L]) and Cushing's control group (bias = 1.3% [-3.7 nmol/L]). This was in stark contrast to the metyrapone therapy group (bias = 23% [59 nmol/L]). The difference between LC-MS/MS versus immunoassay in the metyrapone therapy group positively correlated with metyrapone dose and serum 11-deoxycortisol concentration (Pearson's correlation coefficient r = 0.47, 95% CI 0.32-0.61; P < 0.0001). CONCLUSIONS: These data show that liability of immunoassay measurement of serum cortisol to interference in patients receiving metyrapone may lead to erroneous clinical decisions concerning dose titration.

Integrity signals

Registry

Crossref · 10.1258/acb.2011.011014

Cites

Statistics

Recomputing p-values needs the paper’s full text.

Claims the paper makes

This paper’s full text isn’t openly available, so its claims and self-check weren’t run. The registry and citation checks still apply.

Claims other papers make about this one

Each is checked against this paper’s own text: does it say what the citing paper says it does?

  • Immunoassay cortisol measurements in patients taking metyrapone show a positive bias relative to a routine LC-MS/MS assay.

    “Immunoassay cortisol measurements in patients taking metyrapone have also been reported to display a positive bias relative to a routine LC-MS/MS assay (10,11 ).”
  • The first generation Roche E170 and Siemens Centaur XP assays were particularly prone to over-estimation in the metyrapone cohort, likely secondary to antibody cross-reactivity with cortisol precursors.

    “Of these, the first generation Roche E170 and Siemens Centaur XP were particularly prone to over-estimation, likely secondary to antibody cross-reactivity with cortisol precursors (10,11 ).”

The citation lists haven’t been fetched yet

References 15 · Cited by 111

Authors
Monaghan, P. J., Owen, L. J., Trainer, P. J., Brabant, G., Keevil, B. G., & Darby, D.
Affiliations
  • The Christie Hospital (GB)
  • Biochemistry Department, University Hospital of South Manchester, Manchester M23 9LT
  • The Christie NHS Foundation Trust (GB)
Corresponding author
Monaghan, Phillip J
Venue
Annals of Clinical Biochemistry International Journal of Laboratory Medicine
Published
2011-08-03
Volume
48
Issue
5
Pages
441-446
ISSN
  • 0004-5632 (ISSN-L)
  • 1758-1001
OpenAlex
W2111887351
Cited by
111
References
15
Citations by year
2026: 6 · 2025: 11 · 2024: 3 · 2023: 10 · 2022: 8 · 2021: 9 · 2020: 15 · 2019: 4 · 2018: 5 · 2017: 4 · 2016: 7 · 2015: 11 · 2014: 7 · 2013: 6 · 2012: 5
FWCI
3.93
Type
journal article
Language
en
Open access
closed
Locations
  • Annals of Clinical Biochemistry International Journal of Laboratory Medicine (publishedVersion)
  • PubMed (publishedVersion)
  • Research Explorer (The University of Manchester) (submittedVersion)
Topics
  • Health Sciences › Medicine › Physiology › Clinical Laboratory Practices and Quality Control
  • Health Sciences › Medicine › Endocrinology, Diabetes and Metabolism › Adrenal Hormones and Disorders
  • Life Sciences › Neuroscience › Behavioral Neuroscience › Stress Responses and Cortisol
Keywords
metyrapone, immunoassay interference, 11β-hydroxylase inhibitor, Cushing's syndrome, 11-deoxycortisol, assay comparison, LC-MS/MS
MeSH terms
Chromatography, Liquid, Cushing Syndrome, False Positive Reactions, Humans, Hydrocortisone, Immunoassay, Metyrapone, Steroid 11-beta-Hydroxylase, Drug Monitoring, Diagnostic Techniques and Procedures, Tandem Mass Spectrometry

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review