The DOI matches its Crossref record.
Computerized transverse axial scanning (tomography): Part 2. Clinical application*
Abstract
A new and fundamentally different X-ray method is described. The cranium is scanned in successive layers by a narrow beam of X rays, in such a way that the transmission of the X-ray photons across a particular layer can be measured, and by means of a computer, used to construct a picture of the internal structure. Employing a suitably designed scanning gantry, a continuously operating X-ray tube, and a narrow collimated X-ray beam, the transmissions of X-ray photons across a slice of tissue may be measured by a system of crystal detectors in such a way that 28,800 readings are obtained. These form the basis of 28,000 simultaneous equations which are solved by a computer. The solutions are transformed into absorption coefficients and by means of a suitable algorithm related to their correct cells in a matrix of chosen size. The results are stored, computed, and then made available from a magnetic disc to construct a picture on a CRT. The numerical results are available from a print-out. The examination is, therefore, qualitative and quantitative. Pictures thus obtained are looked at in much the same way as radiographs. Structures are identified and shape, size, and position defined. Changes in tissue density are then looked for. Lesions are seen as alterations of normal density and are interpreted in the light of pathological changes which are known to occur. Increased density may be due to blood clot, calcium deposition in tumours, and other lesions. In haemorrhage, once clotting has occurred, the concentrated blood constituents show up as an area of high density. Average tissue density is lowered in tissue necrosis, oedema, cyst formation, and haemorrhage where clotting has not occurred. Tissue density may be artificially enhanced by the intravenous injection of substances containing large atoms;sodium iothalamate has been found to be ideal and the tissue density of a variety of tumours may be enhanced by this means.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Three-dimensional real-time in vivo magnetic particle imaging
Weizenecker, J., Gleich, B., Rahmer, J., Dahnke, H., & Borgert, J. (2009) · Physics in Medicine and Biology · doi:10.1088/0031-9155/54/5/l01 · Cited by 651
Hounsfield, G. N. (1980) · Science · doi:10.1126/science.6997993 · Cited by 366
The Validity of Criteria for the Evaluation of Cerebral Atrophy by Computed Tomography
Huckman, M. S., Fox, J., & Topel, J. (1975) · Radiology · doi:10.1148/116.1.85 · Cited by 313
Trelease, R. B. (2016) · Anatomical Sciences Education · doi:10.1002/ase.1620 · Cited by 266
Risk of Brain Tumor Induction from Pediatric Head CT Procedures: A Systematic Literature Review
Sheppard, J. P., Nguyen, T., Alkhalid, Y., Beckett, J. S., Salamon, N., & Yang, I. (2018) · Brain Tumor Research and Treatment · doi:10.14791/btrt.2018.6.e4 · Cited by 90
Metadata
- Authors
- Ambrose, J.
- Venue
- The British Journal of Radiology
- Publisher
- Oxford University Press (OUP)
- Published
- 1973-12
- Volume
- 46
- Issue
- 552
- Pages
- 1023-1047
- ISSN
- 0007-1285 (ISSN-L)
- 1748-880X
- OpenAlex
- W2164405799
- Cited by
- 840
- References
- 0
- FWCI
- 87.30
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Computerized transverse axial scanning (tomography): Part 2. Clinical application*. https://app.cochat.ai/papers/10.1259/0007-1285-46-552-1023
- The paper
- Ambrose, J. (1973). Computerized transverse axial scanning (tomography): Part 2. Clinical application*. The British Journal of Radiology. https://doi.org/10.1259/0007-1285-46-552-1023
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.