The DOI matches its Crossref record.
X-ray dual-photon absorptiometry: a new method for the measurement of bone density
Abstract
A recently introduced method (dual-photon X-ray absorptiometry, DEXA) capable of measuring skeletal density in man (at present in the spine and hips, but ultimately for the whole body) has been evaluated in terms of its ability to perform longterm assessment of bone density changes. The method, which uses X rays rather than γ rays as its photon source, represents a significant improvement over present systems both in image quality and precision (reproducibility) of results, which is better than 1% in vivo. Scannning time is approximately halved compared with present techniques and the radiation dose is reduced by 25%. First data on long-term drift of results and effects of changes in patient composition (i.e. thickness and fat content) are given and show the new method to be superior to present radionuclide systems. It is likely that this new method will become the standard for bone density measurements.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Noninvasive assessment of bone mineral and structure: State of the art
Genant, H. K., Engelke, K., Fuerst, T., Glüer, C.-C., Grampp, S., Harris, S. T., Jergas, M., Lang, T., Lu, Y., Majumdar, S., et al. (1996) · Journal of Bone and Mineral Research · doi:10.1002/jbmr.5650110602 · Cited by 941
Genant, H. K., Grampp, S., Glüer, C. C., Faulkner, K. G., Jergas, M., Engelke, K., Hagiwara, S., & van Kuijk, C. (1994) · Journal of Bone and Mineral Research · doi:10.1002/jbmr.5650091002 · Cited by 610
Quantitative computed tomography
Adams, J. E. (2009) · European Journal of Radiology · doi:10.1016/j.ejrad.2009.04.074 · Cited by 458
Dual-energy X-ray absorptiometry and body composition
Laskey, M. A. (1996) · Nutrition · doi:10.1016/0899-9007(95)00017-8 · Cited by 407
Reduced bone mineral density in patients with adult onset growth hormone deficiency
Holmes, S. J. (1994) · Journal of Clinical Endocrinology & Metabolism · doi:10.1210/jc.78.3.669 · Cited by 340
Metadata
- Authors
- Cullum, I. D., Ell, P. J., & Ryder, J. P.
- Venue
- The British Journal of Radiology
- Publisher
- Oxford University Press (OUP)
- Published
- 1989-07-01
- Volume
- 62
- Issue
- 739
- Pages
- 587-592
- ISSN
- 0007-1285 (ISSN-L)
- 1748-880X
- OpenAlex
- W1972496801
- Cited by
- 216
- References
- 0
- FWCI
- 14.47
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: X-ray dual-photon absorptiometry: a new method for the measurement of bone density. https://app.cochat.ai/papers/10.1259/0007-1285-62-739-587
- The paper
- Cullum, I. D., Ell, P. J., & Ryder, J. P. (1989). X-ray dual-photon absorptiometry: a new method for the measurement of bone density. The British Journal of Radiology. https://doi.org/10.1259/0007-1285-62-739-587
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.