Errors due to non-uniform distribution of fat in dual X-ray absorptiometry of the lumbar spine
The DOI matches its Crossref record.
Abstract
Errors in spinal dual X-ray absorptiometry (DXA) were studied by analysing X-ray CT scans taken for diagnostic purposes on 20 patients representing a wide range of fat content. The mean difference between the fat thickness over the vertebral bodies and that over a background area in antero-posterior (AP) scanning was 6.7 ± 8.1 mm for men and 13.4 ± 4.7 mm for women. For lateral scanning the mean fat thickness difference was only 4 mm for both sexes, but the dispersion was greater, with a standard deviation of 15 mm. To relate these differences to errors in bone mineral, measurements were made of the bone mineral equivalence of fat-equivalent materials on DXA machines from three manufacturers. 10 mm of adipose tissue was equivalent to –0.043 g/cm2 of hydroxyapatite. For AP scanning a non-uniform fat distribution leads to a mean overestimate of 0.029 g/cm2 for men and 0.057 g/cm2 for women. The error exceeded 0.1 g/cm2 in 10% of slices. For lateral scanning the error exceeded 0.1 g/cm2 (about 15% of normal) in a quarter of slices.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Noninvasive assessment of bone mineral and structure: State of the art
Genant, H. K., Engelke, K., Fuerst, T., Glüer, C.-C., Grampp, S., Harris, S. T., Jergas, M., Lang, T., Lu, Y., Majumdar, S., et al. (1996) · Journal of Bone and Mineral Research · doi:10.1002/jbmr.5650110602 · Cited by 941
Growth Hormone, Insulin-Like Growth Factors, and the Skeleton
Giustina, A., Mazziotti, G., & Canalis, E. (2008) · Endocrine Reviews · doi:10.1210/er.2007-0036 · Cited by 914
Human Body Composition: In Vivo Methods
Ellis, K. J. (2000) · Physiological Reviews · doi:10.1152/physrev.2000.80.2.649 · Cited by 825
Dual-energy X-ray absorptiometry and body composition
Laskey, M. A. (1996) · Nutrition · doi:10.1016/0899-9007(95)00017-8 · Cited by 407
Intentional and Unintentional Weight Loss Increase Bone Loss and Hip Fracture Risk in Older Women
Ensrud, K. E., Ewing, S. K., Stone, K. L., Cauley, J. A., Bowman, P. J., Cummings, S. R., & for the Study of Osteoporotic Fractures Research Group (2003) · Journal of the American Geriatrics Society · doi:10.1046/j.1532-5415.2003.51558.x · Cited by 336
Metadata
- Authors
- Tothill, P., & Pye, D. W.
- Venue
- The British Journal of Radiology
- Publisher
- Oxford University Press (OUP)
- Published
- 1992-09-01
- Volume
- 65
- Issue
- 777
- Pages
- 807-813
- ISSN
- 0007-1285 (ISSN-L)
- 1748-880X
- OpenAlex
- W2142795119
- Cited by
- 106
- References
- 0
- FWCI
- 4.86
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Errors due to non-uniform distribution of fat in dual X-ray absorptiometry of the lumbar spine. https://app.cochat.ai/papers/10.1259/0007-1285-65-777-807
- The paper
- Tothill, P., & Pye, D. W. (1992). Errors due to non-uniform distribution of fat in dual X-ray absorptiometry of the lumbar spine. The British Journal of Radiology. https://doi.org/10.1259/0007-1285-65-777-807
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.