CoChat

Pneumothorax rates in CT-Guided lung biopsies: a comprehensive systematic review and meta-analysis of risk factors

Open access
Huo, Ya Ruth, Chan, Michael Vinchill, Habib, Al-Rahim, Lui, Isaac, Ridley, Lloyd · 2020 · The British Journal of Radiology
Cited by 216

The DOI matches its Crossref record; 20 of the 20 references it cites were found in a registry or an index.

Abstract

Objective: This systematic review and meta-analysis investigated risk factors for pneumothorax following CT-guided percutaneous transthoracic lung biopsy. Methods: A systematic search of nine literature databases between inception to September 2019 for eligible studies was performed. Results: 36 articles were included with 23,104 patients. The overall pooled incidence for pneumothorax was 25.9% and chest drain insertion was 6.9%. Pneumothorax risk was significantly reduced in the lateral decubitus position where the biopsied lung was dependent compared to a prone or supine position [odds ratio (OR):3.15]. In contrast, pneumothorax rates were significantly increased in the lateral decubitus position where the biopsied lung was non-dependent compared to supine (OR:2.28) or prone position (OR:3.20). Other risk factors for pneumothorax included puncture site up compared to down through a purpose-built biopsy window in the CT table (OR:4.79), larger calibre guide/needles (≤18G vs >18G: OR 1.55), fissure crossed (OR:3.75), bulla crossed (OR:6.13), multiple pleural punctures (>1 vs 1: OR:2.43), multiple non-coaxial tissue sample (>1 vs 1: OR 1.99), emphysematous lungs (OR:3.33), smaller lesions (<4 cm vs 4 cm: OR:2.09), lesions without pleural contact (OR:1.73) and deeper lesions (≥3 cm vs <3cm: OR:2.38). Conclusion: This meta-analysis quantifies factors that alter pneumothorax rates, particularly with patient positioning, when planning and performing a CT-guided lung biopsy to reduce pneumothorax rates. Advances in knowledge: Positioning patients in lateral decubitus with the biopsied lung dependent, puncture site down with a biopsy window in the CT table, using smaller calibre needles and using coaxial technique if multiple samples are needed are associated with a reduced incidence of pneumothorax.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1259/bjr.20190866

Cites

20 of 20 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Metadata

Authors
Huo, Y. R., Chan, M. V., Habib, A.-R., Lui, I., & Ridley, L.
Venue
The British Journal of Radiology
Published
2020-01-03
Volume
93
Issue
1108
Pages
20190866-20190866
ISSN
  • 0007-1285 (ISSN-L)
  • 1748-880X
OpenAlex
W2996669427
Cited by
216
References
20
FWCI
2.78
Type
journal article
Language
en
Open access
green

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.