Radiation dose and in vitro precision in paediatric bone mineral density measurement using dual X-ray absorptiometry.
The DOI matches its Crossref record.
Abstract
Dual X-ray absorptiometry (DXA) is one of the most widely used techniques for non-invasive assessment of bone integrity. There is a growing demand for measurement of paediatric bone status. In DXA the principal radiation risks to patients are the carcinogenic and genetic effects. Radiation dosimetry is well established for DXA in adults, but there are limited paediatric data available. We report on a study to estimate the effective doses (EDs) received by typical 5- and 10-year-old children using the paediatric scan mode on the Lunar DPX-L bone mineral density scanner. Entrance surface doses (ESDs) and percentage depth doses for the total body and PA spine scan modes were measured using lithium borate thermoluminescent dosemeters (TLDs) located at the surface and distributed at various organ locations in anthropomorphic child phantoms. The EDs were calculated from the percentage depth doses, amount of each organ irradiated and tissue weighting factors. The ESDs were measured to be 6.0 and 0.12 microGy for the posteroanterior (PA) spine and total body, respectively. PA spine EDs were calculated as 0.28 and 0.20 microSv for the 5- and 10-year-old, respectively. Total body EDs were 0.03 and 0.02 microSv for the 5- and 10-year-old children, respectively. These results compare with an adult ED of 0.21 microSv for the PA spine. They are also more than two orders of magnitude lower than reported ESDs and EDs for paediatric chest X-rays. Bone mineral density (BMD) short-term in vitro precision was 0.5% and 1% in the 5- and 10-year-old phantoms, respectively. In conclusion, the Lunar DPX-L in the paediatric mode has a high precision and very low radiation doses, similar to those reported for the adult mode.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Radiation exposure in X-ray-based imaging techniques used in osteoporosis
Damilakis, J., Adams, J. E., Guglielmi, G., & Link, T. M. (2010) · European Radiology · doi:10.1007/s00330-010-1845-0 · Cited by 356
Radiation exposure in bone mineral density assessment
Njeh, C. F., Fuerst, T., Hans, D., Blake, G. M., & Genant, H. K. (1999) · Applied Radiation and Isotopes · doi:10.1016/s0969-8043(98)00026-8 · Cited by 274
Self-citationThe relationship between lean body mass and bone mineral content in paediatric health and disease
Crabtree, N. J., Kibirige, M. S., Fordham, J. N., Banks, L. M., Muntoni, F., Chinn, D., Boivin, C. M., & Shaw, N. J. (2004) · Bone · doi:10.1016/j.bone.2004.06.009 · Cited by 212
“22 ASv [39].”
Self-citationPediatric body composition analysis with dual-energy X-ray absorptiometry.
Helba, M., & Binkovitz, L. A. (2009) · Pediatric Radiology · doi:10.1007/s00247-009-1247-0 · Cited by 127
Sciannamblo, M., Russo, G., Cuccato, D., Chiumello, G., & Mora, S. (2006) · The Journal of Clinical Endocrinology & Metabolism · doi:10.1210/jc.2005-2823 · Cited by 82
Metadata
- Authors
- Njeh, C. F., Samat, S. B., Nightingale, A., McNeil, E. A., & Boivin, C. M.
- Venue
- The British Journal of Radiology
- Publisher
- Oxford University Press (OUP)
- Published
- 1997-07-01
- Volume
- 70
- Issue
- 835
- Pages
- 719-727
- ISSN
- 0007-1285 (ISSN-L)
- 1748-880X
- OpenAlex
- W2087487995
- Cited by
- 71
- References
- 0
- FWCI
- 3.78
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Radiation dose and in vitro precision in paediatric bone mineral density measurement using dual X-ray absorptiometry. https://app.cochat.ai/papers/10.1259/bjr.70.835.9245884
- The paper
- Njeh, C. F., Samat, S. B., Nightingale, A., McNeil, E. A., & Boivin, C. M. (1997). Radiation dose and in vitro precision in paediatric bone mineral density measurement using dual X-ray absorptiometry. The British Journal of Radiology. https://doi.org/10.1259/bjr.70.835.9245884
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.