Anomalies in dual energy X-ray absorptiometry measurements of total-body bone mineral during weight change using Lunar, Hologic and Norland instruments.
The DOI matches its Crossref record; 1 of the 1 references it cites were found in a registry or an index.
Abstract
A previous study showed that measurements of total-body bone mineral changes made with a Hologic QDR 1000W were unreliable when the subjects underwent weight change. The study has been extended to dual energy X-ray absorptiometry (DXA) apparatus from other manufacturers. Re-analysis of published results during weight loss using a Lunar DPX showed that they varied with the software used. Using the Extended mode, there was a 1% loss of bone mineral areal density (BMD), but no significant change in bone mineral content (BMC) or bone area (BA) following a weight loss of 16 kg, whereas the use of the Standard mode led to a larger fall of BMC and BMD. Similar findings arose from the consideration of two studies using Norland XR 26 HS absorptiometers. On the other hand, separation of two groups with similar weight changes from the population studied with a Hologic QDR 1000W confirmed that BMC changed directly with weight, but there was an inverse relationship for BMD, owing to an inappropriate change of BA. The use of Hologic Enhanced and Standard software modes led to significant differences in initial readings and measured changes. With each instrument there was a strong correlation between changes in BA and changes in BMC. When 6 kg of lard was wrapped around the limbs of volunteers or a semi-anthropomorphic phantom to simulate weight change, there were spurious increases of measured BMC and BA by about 5% with each instrument. There were no changes of BMD with Lunar, variable results with Norland, but decreases with Hologic. The results observed in vivo could be explained by the effects of fat changes, without there being any real change of bone mineral. Changes of BMD in the skeleton of the phantom were underestimated with all three brands. The anomaly observed with the Hologic QDR 1000W is less apparent with a Lunar DPX or a Norland XR 26, but there are sufficient uncertainties for all total-body measurements during weight change to be treated with suspicion.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Madsen, O. R., Jensen, J.-E. B., & S�rensen, O. H. (1997) · European Journal of Applied Physiology · doi:10.1007/s004210050204 · Cited by 60 · cited 2×
“However, Madsen et al [13] reported the effects of adding lard uniformly to the arms, trunk and legs of 11 subjects using Norland XR 26 equipment and software which seem to be equivalent to ours.”
BackgroundMethod
Cited by
LeBlanc, E. S., O'Connor, E., Whitlock, E. P., Patnode, C. D., & Kapka, T. (2011) · Annals of Internal Medicine · doi:10.7326/0003-4819-155-7-201110040-00006 · Cited by 400
Eser, P., Frotzler, A., Zehnder, Y., Wick, L., Knecht, H., Denoth, J., & Schiessl, H. (2004) · Bone · doi:10.1016/j.bone.2004.01.001 · Cited by 323
Obesity and fractures in postmenopausal women
Premaor, M. O., Pilbrow, L., Tonkin, C., Parker, R. A., & Compston, J. (2010) · Journal of Bone and Mineral Research · doi:10.1359/jbmr.091004 · Cited by 305
Simulated increases in body fat and errors in bone mineral density measurements by DXA and QCT
Yu, E. W., Thomas, B. J., Brown, J. K., & Finkelstein, J. S. (2012) · Journal of Bone and Mineral Research · doi:10.1002/jbmr.506 · Cited by 300
Review article: the nutritional and pharmacological consequences of obesity surgery
Stein, J., Stier, C., Raab, H., & Weiner, R. (2014) · Alimentary Pharmacology & Therapeutics · doi:10.1111/apt.12872 · Cited by 256
Metadata
- Authors
- Tothill, P., Laskey, M. A., Orphanidou, C. I., & van Wijk, M.
- Venue
- The British Journal of Radiology
- Publisher
- Oxford University Press (OUP)
- Published
- 1999-07-01
- Volume
- 72
- Issue
- 859
- Pages
- 661-669
- ISSN
- 0007-1285 (ISSN-L)
- 1748-880X
- OpenAlex
- W2035377083
- Cited by
- 96
- References
- 1
- FWCI
- 3.49
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Anomalies in dual energy X-ray absorptiometry measurements of total-body bone mineral during weight change using Lunar, Hologic and Norland instruments. https://app.cochat.ai/papers/10.1259/bjr.72.859.10624323
- The paper
- Tothill, P., Laskey, M. A., Orphanidou, C. I., & van Wijk, M. (1999). Anomalies in dual energy X-ray absorptiometry measurements of total-body bone mineral during weight change using Lunar, Hologic and Norland instruments. The British Journal of Radiology. https://doi.org/10.1259/bjr.72.859.10624323
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.