Validation of a dual energy X-ray absorptiometer: measurement of bone mass and soft tissue composition
Abstract
We investigated the reproducibility of total and regional body composition measurements performed on a dual energy X-ray absorptiometer (DXA). A group of 58 women aged 21-81 (mean 52.4) years was scanned twice with repositioning to determine intraobserver reproducibility of measurements of bone mineral density (BMD, g.cm-2), bone mineral content (BMC, g), lean mass (LM, kg) and fat mass (FM, kg) of the total body and of the major subregions of the body. In addition, the ability of the DXA machine to detect changes in LM and FM (simulated by placing 11.1 and 22.3 kg porcine lard on the body of 11 subjects) was examined. Coefficients of variations calculated from the root mean square averages of individual standard deviations were as follows (BMD, BMC, LM, FM) [corrected]: 1.4%, 1.1%, 1.4%, 1.7% (total body), 2.2%, 2.1%,-,- (head), 2.8%, 2.8%, 2.0%, 2.2% (trunk), 3.6%, 3.9%, 4.0%, 4.9% (arms), 2.7%, 1.3%, 2.6%, 2.8% (legs). Percentage fat (%fat) of exogenous lard was 81.3 (SD 3.5)% as assessed by the absorptiometer which corresponded well with the result of chemical analysis (82.8%). Estimated %fat of exogenous lard was not influenced by initial body mass or percentage body fat. Percentages of expected mean values with 11.1 kg lard placed on the body were 99.9 (SD 0.3) for body mass, 100.5 (SD 2.1) for LM, and 99.5 (SD 3.5) for FM. BMD was overestimated by 3.2% (P < 0.005) with 11.1 kg lard on the body. BMD as well as BMC increased significantly with 22.3 kg lard on the body (P < 0.005). The results showed that BMD, BMC, LM, and FM of the total body were precisely estimated by the DXA machine used. Regional measurements were less precise. Changes in total body soft tissue composition were precisely and accurately estimated. The lard placed on the body falsely affected BMD and BMC measurements. Changes in body mass could have a similar effect.
Integrity signals
Registry
Cites
Statistics
Claims the paper makes
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
Sleeve gastrectomy produces weight loss between that of purely restrictive and malabsorptive procedures.
“Sleeve gastrectomy is becoming increasingly common, with weight loss falling between the purely restrictive and malabsorptive procedures (1 to 2 year weight loss: 20-30%; excess BMI loss: 45-80%).36, 46-50.”
From Bone loss after bariatric surgery: causes, consequences, and management (2014) · cites this paper as [36]
After gastric banding, patients typically lose 20-30% of initial body weight and 41-54% of excess body weight.
“After GB, patients typically lose 20-30% of initial body weight and 41-54% of excess body weight36, 37.”
From Bone loss after bariatric surgery: causes, consequences, and management (2014) · cites this paper as [36]
Cites
Mazess, R., Barden, H. S., Bisek, J., & Hanson, J. (1990) · American Journal of Clinical Nutrition · doi:10.1093/ajcn/51.6.1106 · Cited by 1,465 · see citing works
Glüer, C.-C., Blake, G. M., Lü, Y., Blunt, B. A., Jergas, M. D., & Genant, H. K. (1995) · Osteoporosis International · doi:10.1007/bf01774016 · Cited by 1,282 · see citing works
Heymsfield, S. B., Wang, J., Heshka, S., Kehayias, J. J., & Pierson, R. N. (1989) · American Journal of Clinical Nutrition · doi:10.1093/ajcn/49.6.1283 · Cited by 277 · see citing works
Fuller, N. J., Laskey, M. A., & Elia, M. (1992) · Clinical Physiology · doi:10.1111/j.1475-097x.1992.tb00831.x · Cited by 232 · see citing works
Bone loss accompanying voluntary weight loss in obese humans
Jensen, L. B., QUAADE, F., & Sørensen, O. H. (1994) · Journal of Bone and Mineral Research · doi:10.1002/jbmr.5650090404 · Cited by 151 · see citing works
Self-citationMeasurement of lean body mass and total body fat using dual photon absorptiometry
Gotfredsen, A., Jensen, J., Borg, J., & Christiansen, C. (1986) · Metabolism · doi:10.1016/0026-0495(86)90101-0 · Cited by 139 · see citing works
Self-citationAssessment of whole-body composition with dual-energy x-ray absorptiometry.
Slosman, D. O., Casez, J.-P., Pichard, C., Rochat, T., Féry, F., Rizzoli, R., Bonjour, J. ‐., Morabia, A., & Donath, A. (1992) · Radiology · doi:10.1148/radiology.185.2.1410379 · Cited by 139 · see citing works
Sievänen, H. T., Oja, P., & Vuori, I. (1992) · PubMed · Cited by 129 · see citing works
Wellens, R., Chumlea, W., Guo, S., Af, R., Reo, N., & Siervogel, R. M. (1994) · American Journal of Clinical Nutrition · doi:10.1093/ajcn/59.3.547 · Cited by 95 · see citing works
CLARK, R. R., KUTA, J. M., & SULLIVAN, J. C. (1993) · Medicine & Science in Sports & Exercise · doi:10.1249/00005768-199304000-00017 · Cited by 54 · see citing works
Madsen, O. R., Lauridsen, U. B., Hartkopp, A., & S�rensen, O. H. (1997) · European Journal of Applied Physiology · doi:10.1007/s004210050154 · Cited by 46 · see citing works
Self-citationFactors influencing short-term precision of dual X-ray bone absorptiometry (DXA) of spine and femur
Engelke, K., Gl�er, C. C., & Genant, H. K. (1995) · Calcified Tissue International · doi:10.1007/bf00298739 · Cited by 42 · see citing works
Measurement of bone mineral density
Hassager, C., & Christiansen, C. (1995) · Calcified Tissue International · doi:10.1007/bf00298987 · Cited by 33 · see citing works
Flagged first, then by citations
Cited by
Sorted by citations
Nana, A., Slater, G. J., Stewart, A. D., & Burke, L. M. (2015) · International Journal of Sport Nutrition and Exercise Metabolism · doi:10.1123/ijsnem.2013-0228 · Cited by 372 · see citing works
Simulated increases in body fat and errors in bone mineral density measurements by DXA and QCT
Yu, E. W., Thomas, B. J., Brown, J. K., & Finkelstein, J. S. (2012) · Journal of Bone and Mineral Research · doi:10.1002/jbmr.506 · Cited by 300 · see citing works
Bone loss after bariatric surgery: causes, consequences, and management
Stein, E. M., & Silverberg, S. J. (2014) · The Lancet Diabetes & Endocrinology · doi:10.1016/s2213-8587(13)70183-9 · Cited by 199 · see citing works
Lalmohamed, A., de Vries, F., Bazelier, M. T., Cooper, A., van Staa, T.-P., Cooper, C., & Harvey, N. C. (2012) · BMJ · doi:10.1136/bmj.e5085 · Cited by 173 · see citing works
Bariatric surgery, bone loss, obesity and possible mechanisms
Brzozowska, M. M., Sainsbury, A., Eisman, J. A., Baldock, P. A., & Center, J. R. (2013) · Obesity Reviews · doi:10.1111/j.1467-789x.2012.01050.x · Cited by 128 · see citing works
Giusti, V, Gasteyger, C., Suter, M., Heraief, E., Gaillard, R. C., & Burckhardt, P. (2005) · International Journal of Obesity · doi:10.1038/sj.ijo.0803040 · Cited by 91 · see citing works
Lamont, H. S., Cramer, J. T., Bemben, D. A., Shehab, R. L., Anderson, M. A., & Bemben, M. G. (2011) · Journal of Strength and Conditioning Research · doi:10.1519/jsc.0b013e3181e7ffad · Cited by 25 · see citing works
Yang, Y., Zhu, W. J., & Paton, N. I. (2004) · Antiviral Therapy · doi:10.1177/135965350400900516 · Cited by 15 · see citing works
- Authors
- Madsen, O. R., Jensen, J.-E. B., & S�rensen, O. H.
- Affiliations
- University of Copenhagen (DK)
- Venue
- European Journal of Applied Physiology
- Published
- 1997-05-01
- Volume
- 75
- Issue
- 6
- Pages
- 554-558
- ISSN
- 0020-9376 (ISSN-L)
- 1439-6319
- 1439-6327
- OpenAlex
- W2021767918
- Cited by
- 60
- References
- 13
- Citations by year
- 2025: 1 · 2024: 1 · 2023: 1 · 2022: 1 · 2019: 2 · 2017: 3 · 2016: 1 · 2015: 3 · 2014: 6 · 2013: 3 · 2012: 5
- FWCI
- 1.22
- Type
- journal article
- Language
- en
- Open access
- closed
- Licence
- www.springer.com/tdm (tdm)
- Locations
- European Journal of Applied Physiology (publishedVersion)
- PubMed (publishedVersion)
- Topics
- Health Sciences › Medicine › Physiology › Body Composition Measurement Techniques
- Health Sciences › Medicine › Orthopedics and Sports Medicine › Bone health and osteoporosis research
- Health Sciences › Medicine › Emergency Medicine › HIV-related health complications and treatments
- Keywords
- dual-energy X-ray absorptiometry, measurement reproducibility, bone mineral density, bone mineral content, lean body mass, fat mass, body composition, soft tissue composition, fat detection, regional body composition, women, body mass index, body fat percentage, measurement error, coefficient of variation, body fat distribution
- MeSH terms
- Adipose Tissue, Adult, Aged, Body Composition, Dietary Fats, Female, Humans, Middle Aged, Reproducibility of Results, Absorptiometry, Photon, Bone Density
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review