Geometry of proximal femur in the prediction of hip fracture in osteoporotic women.
Open accessThe DOI matches its Crossref record; 1 of the 1 references it cites were found in a registry or an index.
Abstract
111 White post-menopausal women with hip fracture and 329 healthy controls were studied in order to determine whether proximal femur geometry predicts hip fracture and improves the discriminant ability of femoral neck bone mineral density (BMD) in elderly women. All subjects underwent dual X-ray photon absorptiometry (DXA) of the hip from which the femoral neck BMD, hip axis length, femoral neck width and femoral neck-shaft angle were measured. Fractured subjects had a lower femoral neck BMD, a longer hip axis length and a more valgus neck-shaft angle. The hip axis length correlated significantly with neck-shaft angle, femoral neck width and age. No significant correlation was found between neck-shaft angle and age. On standardized logistic regression, the hip axis length and the neck-shaft angle predicted fracture independently of BMD after correction for age, weight and femoral neck BMD. The femoral neck BMD significantly discriminated fractured subjects after correction for all potential confounders. The logistic models containing simultaneously one femoral geometric parameter and the neck BMD discriminated significantly better than those containing the same variables as single predictor. Our data suggest that hip axis length may play a role in fracture risk and supports a similar role for neck-shaft angle. Combining proximal femur geometric measurements and femoral neck BMD improved the discriminant ability of each measurement.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Marshall, D., Johnell, O., & Wedel, H. (1996) · BMJ · doi:10.1136/bmj.312.7041.1254 · Cited by 3,709
Cited by
Kaptoge, S., Beck, T. J., Reeve, J., Stone, K. L., Hillier, T. A., Cauley, J. A., & Cummings, S. R. (2008) · Journal of Bone and Mineral Research · doi:10.1359/jbmr.080802 · Cited by 283
Risk Factors Affecting Outcome of Metal-on-Metal Surface Arthroplasty of the Hip
Beaul??, P. E., Dorey, F. J., LeDuff, M., Gruen, T., & Amstutz, H. C. (2004) · Clinical Orthopaedics and Related Research · doi:10.1097/00003086-200401000-00015 · Cited by 254
Rivadeneira, F., Zillikens, M. C., De Laet, C. E., Hofman, A., Uitterlinden, A. G., Beck, T. J., & Pols, H. A. (2007) · Journal of Bone and Mineral Research · doi:10.1359/jbmr.070712 · Cited by 177
Bone geometry and skeletal fragility
Bouxsein, M. L., & Karasik, D. (2006) · Current Osteoporosis Reports · doi:10.1007/s11914-006-0002-9 · Cited by 165
Combination of bone mineral density and upper femur geometry improves the prediction of hip fracture
Pulkkinen, P., Partanen, J., Jalovaara, P., & J�ms�, T. (2004) · Osteoporosis International · doi:10.1007/s00198-003-1556-3 · Cited by 159
“Our finding is in good accordance with other studies, where NSA has been found to be a valuable indicator for the evaluation of hip fracture risk, especially in the case of femoral neck fracture [9, 11, 18, 19].”
BackgroundMethodResultInfluential
Metadata
- Authors
- Gnudi, S., Ripamonti, C., Gualtieri, G., & Malavolta, N.
- Venue
- The British Journal of Radiology
- Publisher
- Oxford University Press (OUP)
- Published
- 1999-08-01
- Volume
- 72
- Issue
- 860
- Pages
- 729-733
- ISSN
- 0007-1285 (ISSN-L)
- 1748-880X
- OpenAlex
- W2105567919
- Cited by
- 146
- References
- 1
- FWCI
- 2.45
- Type
- journal article
- Language
- en
- Open access
- green
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Geometry of proximal femur in the prediction of hip fracture in osteoporotic women. https://app.cochat.ai/papers/10.1259/bjr.72.860.10624337
- The paper
- Gnudi, S., Ripamonti, C., Gualtieri, G., & Malavolta, N. (1999). Geometry of proximal femur in the prediction of hip fracture in osteoporotic women. The British Journal of Radiology. https://doi.org/10.1259/bjr.72.860.10624337
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.