The DOI matches its Crossref record; 10 of the 10 references it cites were found in a registry or an index.
Risk Factors Affecting Outcome of Metal-on-Metal Surface Arthroplasty of the Hip
Abstract
We evaluated radiologic and clinical features affecting the outcome of hybrid metal-on-metal surface arthroplasty of the hip in 119 hips in patients 40 years and younger. Only the hips that had either failed or had minimum 2-year followup were reviewed. Ninety-four hips in 83 patients with a mean age of 34.2 years (range, 15–40 years) were reviewed. Seventy-one percent of the patients were males and 29% of the patients were females; 14% had previous surgery. The Chandler index and surface arthroplasty risk index were calculated. The mean followup at 3 years (range, 2–5 years) showed that three hips were converted to a total hip replacement at a mean of 27 months (range, 2–50 months) after the original surgery, and 10 hips had significant radiologic changes. The mean surface arthroplasty risk index for these 13 problematic hips versus the remaining hips was significantly higher, 4.7 and 2.6, respectively. The mean angle between the prosthesis stem and femoral shaft in the problematic group was significantly smaller than in the remaining hips: 133° and 139°, respectively. With a surface arthroplasty risk index score greater than 3 the relative risk of early problems is 12 times greater than if surface arthroplasty risk index less than or equal to 3.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Assessing activity in joint replacement patients
Zahiri, C. A., Schmalzried, T. P., Szuszczewicz, E. S., & Amstutz, H. C. (1998) · The Journal of Arthroplasty · doi:10.1016/s0883-5403(98)90195-4 · Cited by 914
Self-citationMechanism and Clinical Significance of Wear Debris-Induced Osteolysis
AMSTUTZ, H. C., CAMPBELL, P., KOSSOVSKY, N., & CLARKE, I. C. (1992) · Clinical Orthopaedics and Related Research · doi:10.1097/00003086-199203000-00003 · Cited by 670
Self-citationWear Is a Function of Use, Not Time
Schmalzried, T. P., Shepherd, E. F., Dorey, F. J., Jackson, W. O., dela Rosa, M., Fa???vae, F., McKellop, H. A., McClung, C. D., Martell, J., Moreland, J. R., et al. (2000) · Clinical Orthopaedics and Related Research · doi:10.1097/00003086-200012000-00005 · Cited by 474
Self-citationRelationship of Acetabular Wear to Osteolysis and Loosening in Total Hip Arthroplasty
Sochart, D. H. (1999) · Clinical Orthopaedics and Related Research · doi:10.1097/00003086-199906000-00018 · Cited by 272
A study of implant failure in the Wagner resurfacing arthroplasty.
Bell, R. S., Schatzker, J., Fornasier, V. L., & Goodman, S. B. (1985) · The Journal of Bone & Joint Surgery · doi:10.2106/00004623-198567080-00004 · Cited by 192
Step activity monitor: Increased accuracy in quantifying ambulatory activity
Shepherd, E. F., Toloza, E., McClung, C. D., & Schmalzried, T. P. (1999) · Journal of Orthopaedic Research · doi:10.1002/jor.1100170512 · Cited by 182
Total Hip Arthroplasty with Cement in Patients Less Than Twenty Years Old. Long-Term Results*
Torchia, M. E., Klassen, R. A., & Bianco, A. J. (1996) · Journal of Bone and Joint Surgery · doi:10.2106/00004623-199607000-00003 · Cited by 177
Geometry of proximal femur in the prediction of hip fracture in osteoporotic women.
Gnudi, S., Ripamonti, C., Gualtieri, G., & Malavolta, N. (1999) · British Journal of Radiology · doi:10.1259/bjr.72.860.10624337 · Cited by 166
Alumina-on-Alumina Total Hip Prostheses in Patients 40 Years of Age or Younger
Bizot, P., Banallec, L., Sedel, L., & Nizard, R. (2000) · Clinical Orthopaedics and Related Research · doi:10.1097/00003086-200010000-00010 · Cited by 103
Activity and socket wear in the Charnley low-friction arthroplasty
Feller, J. A., Kay, P., Hodgkinson, J. P., & Wroblewski, B. M. (1994) · The Journal of Arthroplasty · doi:10.1016/0883-5403(94)90042-6 · Cited by 62
Cited by
The operation of the century: total hip replacement
Learmonth, I. D., Young, C., & Rorabeck, C. (2007) · The Lancet · doi:10.1016/s0140-6736(07)60457-7 · Cited by 2,848
Osteonecrosis of the femoral head: Etiology, imaging and treatment
Malizos, K. N., Karantanas, A. H., Varitimidis, S. E., Dailiana, Z. H., Bargiotas, K., & Maris, T. (2007) · European Journal of Radiology · doi:10.1016/j.ejrad.2007.03.019 · Cited by 316
Smith, A. J., Dieppe, P., Howard, P. W., & Blom, A. W. (2012) · The Lancet · doi:10.1016/s0140-6736(12)60989-1 · Cited by 281
Metadata
- Authors
- Beaul??, P. E., Dorey, F. J., LeDuff, M., Gruen, T., & Amstutz, H. C.
- Venue
- Clinical Orthopaedics and Related Research
- Published
- 2004-01
- Volume
- 418
- Pages
- 87-93
- ISSN
- 0009-921X (ISSN-L)
- OpenAlex
- W4320581067
- Cited by
- 254
- References
- 10
- FWCI
- 19.99
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Risk Factors Affecting Outcome of Metal-on-Metal Surface Arthroplasty of the Hip. https://app.cochat.ai/papers/10.1097/00003086-200401000-00015
- The paper
- Beaul??, P. E., Dorey, F. J., LeDuff, M., Gruen, T., & Amstutz, H. C. (2004). Risk Factors Affecting Outcome of Metal-on-Metal Surface Arthroplasty of the Hip. Clinical Orthopaedics and Related Research. https://doi.org/10.1097/00003086-200401000-00015
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.