The DOI matches its Crossref record; 1 of the 1 references it cites were found in a registry or an index.
A combined PET/CT scanner: the path to true image fusion
Abstract
Software-based image fusion is used routinely for the alignment of functional and anatomical images of the brain. For other parts of the body, image registration is more problematic owing to differences in patient positioning, scanner bed profiles and the involuntary movement of internal organs. An alternative to the software approach is a scanner that acquires both function and anatomy during a single imaging session: a fusion of the technologies rather than a fusion of the images post hoc. Consequently, we designed and built a prototype combined PET and CT scanner comprising a clinical CT and a clinical PET scanner mounted together in a single gantry. Over 300 cancer patients have been imaged in the scanner to establish the clinical value of the combined PET/CT approach. The CT images were used to provide essentially noiseless attenuation correction factors for the PET data. The widespread interest created by the patient studies acquired with the prototype PET/CT stimulated commercial activity and several major vendors of medical imaging equipment now offer combined PET/CT designs. This paper reviews the development of the combined PET/CT scanner, and illustrates the clinical aspects with some typical studies in cancer patients. The potential impact on medical practice of the commercial availability of PET/CT scanner technology at affordable cost is assessed.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Attenuation correction for a combined 3D PET/CT scanner
Kinahan, P. E., Townsend, D. W., Beyer, T., & Sashin, D. (1998) · Medical Physics · doi:10.1118/1.598392 · Cited by 946
Self-citation
Cited by
Clinical biomarkers in drug discovery and development
Frank, R., & Hargreaves, R. (2003) · Nature Reviews Drug Discovery · doi:10.1038/nrd1130 · Cited by 794
Lee, H.-Y., Li, Z., Chen, K., Hsu, A. R., Xu, C., Xie, J., Sun, S., & Chen, X. (2008) · Journal of Nuclear Medicine · doi:10.2967/jnumed.108.051243 · Cited by 557
Multimodality Molecular Imaging of Tumor Angiogenesis
Cai, W., & Chen, X. (2008) · Journal of Nuclear Medicine · doi:10.2967/jnumed.107.045922 · Cited by 494
PET/MRI: Paving the Way for the Next Generation of Clinical Multimodality Imaging Applications
Pichler, B. J., Kolb, A., Nägele, T., & Schlemmer, H.-P. (2010) · Journal of Nuclear Medicine · doi:10.2967/jnumed.109.061853 · Cited by 418
Metabolic positron emission tomography imaging in cancer detection and therapy response
Zhu, A., Lee, D., & Shim, H. (2011) · Seminars in Oncology · doi:10.1053/j.seminoncol.2010.11.012 · Cited by 368
“Although FDG-PET has shown great success in cancer diagnosis and assessment of treatment response, FDG has the following limitations: (1) increased accumulation of FDG in some benign processes, such as infectious and inflammatory lesions that can give false positive results; (2) low sensitivity in well-differentiated…”
Metadata
- Authors
- Townsend, D. W., & Beyer, T.
- Venue
- The British Journal of Radiology
- Publisher
- Oxford University Press (OUP)
- Published
- 2002-11
- Volume
- 75
- Issue
- suppl_9
- Pages
- S24-S30
- ISSN
- 0007-1285 (ISSN-L)
- 1748-880X
- OpenAlex
- W2170563062
- Cited by
- 241
- References
- 1
- FWCI
- 11.90
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: A combined PET/CT scanner: the path to true image fusion. https://app.cochat.ai/papers/10.1259/bjr.75.suppl_9.750024
- The paper
- Townsend, D. W., & Beyer, T. (2002). A combined PET/CT scanner: the path to true image fusion. The British Journal of Radiology. https://doi.org/10.1259/bjr.75.suppl_9.750024
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.