Coronary CT angiography: current status and continuing challenges
Open accessThe DOI matches its Crossref record; 84 of the 84 references it cites were found in a registry or an index.
Abstract
Coronary CT angiography has been increasingly used in the diagnosis of coronary artery disease owing to rapid technological developments, which are reflected in the improved spatial and temporal resolution of the images. High diagnostic accuracy has been achieved with multislice CT scanners (64 slice and higher), and in selected patients coronary CT angiography is regarded as a reliable alternative to invasive coronary angiography. With high-quality coronary CT imaging increasingly being performed, patients can benefit from an imaging modality that provides a rapid and accurate diagnosis while avoiding an invasive procedure. Despite the tremendous contributions of coronary CT angiography to cardiac imaging, study results reported in the literature should be interpreted with caution as there are some limitations existing within the study design or related to patient risk factors. In addition, some attention must be given to the potential health risks associated with the ionising radiation received during cardiac CT examinations. Radiation dose associated with coronary CT angiography has raised serious concerns in the literature, as the risk of developing malignancy is not negligible. Various dose-saving strategies have been implemented, with some of the strategies resulting in significant dose reduction. The aim of this review is to present an overview of the role of coronary CT angiography on cardiac imaging, with focus on coronary artery disease in terms of the diagnostic and prognostic value of coronary CT angiography. Various approaches for dose reduction commonly recommended in the literature are discussed. Limitations of coronary CT angiography are identified. Finally, future directions and challenges with the use of coronary CT angiography are highlighted.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Computed Tomography — An Increasing Source of Radiation Exposure
Brenner, D. J., & Hall, E. J. (2007) · New England Journal of Medicine · doi:10.1056/nejmra072149 · Cited by 8,748 · cited 6×
“It is reported that radiation dose from a CT scan has been significantly underestimated by radiologists and physicians [24, 27].”
InfluentialRecommendations of the International Commission on Radiological Protection
(1961) · Postgraduate Medical Journal · doi:10.1136/pgmj.37.425.168-b · Cited by 5,862
WRITING COMMITTEE MEMBERS, Smith, S. C., Feldman, T. E., Hirshfeld, J. W., Jacobs, A. K., Kern, M. J., King, S. B., Morrison, D. A., O’Neill, W. W., Schaff, H. V., et al. (2006) · Circulation · doi:10.1161/circulationaha.105.170815 · Cited by 2,218
Health Risks from Exposure to Low Levels of Ionizing Radiation:: BEIR VII Phase 2
Earth, D. O. (2006) · CERN Document Server (European Organization for Nuclear Research) · Cited by 2,190
Budoff, M. J., Dowe, D., Jollis, J. G., Gitter, M., Sutherland, J., Halamert, E., Scherer, M., Bellinger, R., Martin, A., Benton, R., et al. (2008) · Journal of the American College of Cardiology · doi:10.1016/j.jacc.2008.07.031 · Cited by 2,125 · cited 1×
“This was confirmed by the recently published ACCURACY prospective multicentre study, which included patients with high calcium scores [100].”
Preface, Executive Summary and Glossary
(2007) · Annals of the ICRP · doi:10.1016/j.icrp.2007.10.003 · Cited by 2,106
Diagnostic Performance of Coronary Angiography by 64-Row CT
Miller, J. M., Rochitte, C. E., Dewey, M., Arbab-Zadeh, A., Niinuma, H., Gottlieb, I., Paul, N., Clouse, M. E., Shapiro, E. P., Hoe, J., et al. (2008) · New England Journal of Medicine · doi:10.1056/nejmoa0806576 · Cited by 1,815
Guidelines for Percutaneous Coronary Interventions
Silber, S., Albertsson, P., Avilés, F. F., Camici, P. G., Colombo, A., Hamm, C., Jørgensen, E., Marco, J., Nordrehaug, J.-E., Ruzyllo, W., et al. (2005) · European Heart Journal · doi:10.1093/eurheartj/ehi138 · Cited by 1,609
Current Concepts of the Pathogenesis of the Acute Coronary Syndromes
Libby, P. (2001) · Circulation · doi:10.1161/01.cir.104.3.365 · Cited by 1,558 · cited 1×
“Furthermore, in those patients with coronary disease, the likelihood that an individual coronary plaque will result in acute coronary syndrome is related to many factors, independent of the degree of vascular narrowing [105].”
Material differentiation by dual energy CT: initial experience
Johnson, T. R. C., Krauß, B., Sedlmair, M., Grasruck, M., Bruder, H., Morhard, D., Fink, C., Weckbach, S., Lenhard, M., Schmidt, B., et al. (2007) · European Radiology · doi:10.1007/s00330-006-0517-6 · Cited by 1,510 · cited 1×
“Early reports support the feasibility of using DECT for comprehensive imaging of CAD: with a single-contrast enhanced scan, DECT coronary angiography allows for the assessment of coronary anatomy, detection of coronary stenosis and evaluation of myocardial perfusion imaging [69, 70].”
Cited by
Oikonomou, E. K., Marwan, M., Desai, M. Y., Mancio, J., Alashi, A., Hutt Centeno, E., Thomas, S., Herdman, L., Kotanidis, C. P., Thomas, K. E., et al. (2018) · The Lancet · doi:10.1016/s0140-6736(18)31114-0 · Cited by 1,172
Decision tree-based diagnosis of coronary artery disease: CART model
Ghiasi, M. M., Zendehboudi, S., & Mohsenipour, A. A. (2020) · Computer Methods and Programs in Biomedicine · doi:10.1016/j.cmpb.2020.105400 · Cited by 300
Molecular imaging of plaques in coronary arteries with PET and SPECT.
(2014) · PubMed Central · doi:10.11909/j.issn.1671-5411.2014.03.005 · Cited by 24
Self-citation
Metadata
- Authors
- Sun, Z., Choo, G. H., & Ng, K. H.
- Venue
- The British Journal of Radiology
- Publisher
- Oxford University Press (OUP)
- Published
- 2012-05
- Volume
- 85
- Issue
- 1013
- Pages
- 495-510
- ISSN
- 0007-1285 (ISSN-L)
- 1748-880X
- OpenAlex
- W2132060468
- Cited by
- 189
- References
- 84
- FWCI
- 12.24
- Type
- journal article
- Language
- en
- Open access
- green
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.