The DOI matches its Crossref record; 23 of the 23 references it cites were found in a registry or an index.
Effective dose of dental CBCT—a meta analysis of published data and additional data for nine CBCT units
Open accessAbstract
OBJECTIVES: This article analyses dose measurement and effective dose estimation of dental CBCT examinations. Challenges to accurate calculation of dose are discussed and the use of dose-height product (DHP) as an alternative to dose-area product (DAP) is explored. METHODS: The English literature on effective dose was reviewed. Data from these studies together with additional data for nine CBCT units were analysed. Descriptive statistics, ANOVA and paired analysis are used to characterize the data. RESULTS: PubMed and EMBASE searches yielded 519 and 743 publications, respectively, which were reduced to 20 following review. Reported adult effective doses for any protocol ranged from 46 to 1073 µSv for large fields of view (FOVs), 9-560 µSv for medium FOVs and 5-652 µSv for small FOVs. Child effective doses from any protocol ranged from 13 to 769 µSv for large or medium FOVs and 7-521 µSv for small FOVs. Effective doses from standard or default exposure protocols were available for 167 adult and 52 child exposures. Mean adult effective doses grouped by FOV size were 212 µSv (large), 177 µSv (medium) and 84 µSv (small). Mean child doses were 175 µSv (combined large and medium) and 103 µSv (small). Large differences were seen between different CBCT units. Additional low-dose and high-definition protocols available for many units extend the range of doses. DHP was found to reduce average absolute error for calculation of dose by 45% in comparison with DAP. CONCLUSIONS: Large exposure ranges make CBCT doses difficult to generalize. Use of DHP as a metric for estimating effective dose warrants further investigation.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Computed Tomography — An Increasing Source of Radiation Exposure
Brenner, D. J., & Hall, E. J. (2007) · New England Journal of Medicine · doi:10.1056/nejmra072149 · Cited by 8,748
Recommendations of the International Commission on Radiological Protection
(1961) · Postgraduate Medical Journal · doi:10.1136/pgmj.37.425.168-b · Cited by 5,862
Pearce, M. S., Salotti, J. A., Little, M. P., McHugh, K., Lee, C., Kim, K. P., Howe, N. L., Ronckers, C. M., Rajaraman, P., Craft, A. W., et al. (2012) · The Lancet · doi:10.1016/s0140-6736(12)60815-0 · Cited by 3,735
Estimated Risks of Radiation-Induced Fatal Cancer from Pediatric CT
Brenner, D. J., Elliston, C. D., Hall, E. J., & Berdon, W. E. (2001) · American Journal of Roentgenology · doi:10.2214/ajr.176.2.1760289 · Cited by 3,222 · cited 1×
“In conjunction with a longer life expectancy in which cancer can develop, children may be two times or more sensitive to radiation carcinogenesis than are mature adults.(24,25) Physical differences associated with gender are also associated with differences in risk.”
BackgroundSmith-Bindman, R. (2009) · Archives of Internal Medicine · doi:10.1001/archinternmed.2009.427 · Cited by 2,464
Mathews, J. D., Forsythe, A. V., Brady, Z., Butler, M. W., Goergen, S. K., Byrnes, G. B., Giles, G. G., Wallace, A. B., Anderson, P. R., Guiver, T. A., et al. (2013) · BMJ · doi:10.1136/bmj.f2360 · Cited by 2,029
Cancer risks attributable to low doses of ionizing radiation: Assessing what we really know
Brenner, D. J., Doll, R., Goodhead, D. T., Hall, E. J., Land, C. E., Little, J. B., Lubin, J. H., Preston, D. L., Preston, R. J., Puskin, J. S., et al. (2003) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.2235592100 · Cited by 1,765
Solid Cancer Incidence in Atomic Bomb Survivors: 1958–1998
Preston, D. L., Ron, E., Tokuoka, S., Funamoto, S., Nishi, N., Soda, M., Mabuchi, K., & Kodama, K. (2007) · Radiation Research · doi:10.1667/rr0763.1 · Cited by 1,753
Benefits and costs, an eternal balance
Dixon, A. K. (2007) · Annals of the ICRP · doi:10.1016/j.icrp.2007.09.001 · Cited by 1,355
1990 Recommendations of the International Commission on Radiological Protection.
(1991) · PubMed · Cited by 904
Comparative dosimetry of dental CBCT devices and 64-slice CT for oral and maxillofacial radiology
Ludlow, J. B., & Ivanovic, M. (2008) · Oral Surgery, Oral Medicine, Oral Pathology, Oral Radiology, and Endodontology · doi:10.1016/j.tripleo.2008.03.018 · Cited by 872
Self-citationDosimetry of 3 CBCT devices for oral and maxillofacial radiology: CB Mercuray, NewTom 3G and i-CAT
Ludlow, J., Davies-Ludlow, L., Brooks, S., & Howerton, W. (2006) · Dentomaxillofacial Radiology · doi:10.1259/dmfr/14340323 · Cited by 851
Self-citationEffective dose range for dental cone beam computed tomography scanners
Pauwels, R., Beinsberger, J., Collaert, B., Theodorakou, C., Rogers, J., Walker, A., Cockmartin, L., Bosmans, H., Jacobs, R., Bogaerts, R., et al. (2012) · European Journal of Radiology · doi:10.1016/j.ejrad.2010.11.028 · Cited by 642
Ludlow, J., Davies-Ludlow, L., & Brooks, S. (2003) · Dentomaxillofacial Radiology · doi:10.1259/dmfr/26310390 · Cited by 463
Self-citationActive bone marrow distribution as a function of age in humans
Cristy, M. (1981) · Physics in Medicine & Biology · doi:10.1088/0031-9155/26/3/003 · Cited by 411
Effective dose: how should it be applied to medical exposures?
Martin, C. J. (2007) · The British Journal of Radiology · doi:10.1259/bjr/25922439 · Cited by 377
(1991) · Annals of the ICRP · doi:10.1016/0146-6453(91)90009-6 · Cited by 295
Influence of CBCT exposure conditions on radiation dose
Palomo, J. M., Rao, P. S., & Hans, M. G. (2008) · Oral Surgery Oral Medicine Oral Pathology Oral Radiology and Endodontology · doi:10.1016/j.tripleo.2007.12.019 · Cited by 177
Theodorakou, C., Walker, A., Horner, K., Pauwels, R., Bogaerts, R., Jacobs Dds, R., & The Sedentexct Project Consortium (2012) · The British Journal of Radiology · doi:10.1259/bjr/19389412 · Cited by 173
Assessment of phantom dosimetry and image quality of i-CAT FLX cone-beam computed tomography
Ludlow, J. B., & Walker, C. (2013) · American Journal of Orthodontics and Dentofacial Orthopedics · doi:10.1016/j.ajodo.2013.07.013 · Cited by 161
Self-citationQu, X., Li, G., Ludlow, J. B., et al. (2010) · Oral Surgery Oral Medicine Oral Pathology Oral Radiology and Endodontology · doi:10.1016/j.tripleo.2010.06.013 · Cited by 115
Self-citationLoubele, M., Jacobs, R., Maes, F., Schutyser, F., Debaveye, D., Bogaerts, R., Coudyzer, W., Vandermeulen, D., Cleynenbreugel, J. V., Marchal, G., et al. (2005) · Radiation Protection Dosimetry · doi:10.1093/rpd/nci749 · Cited by 74
Upton, A. C. (2003) · Health Physics · doi:10.1097/00004032-200307000-00005 · Cited by 61
Cited by
Zehnder, M. S., Connert, T., Weiger, R., Krastl, G., & Kühl, S. (2016) · International Endodontic Journal · doi:10.1111/iej.12544 · Cited by 328
Cone-beam CT in paediatric dentistry: DIMITRA project position statement
On behalf of the DIMITRA Research Group, H. D. B., Oenning, A. C., Jacobs, R., Pauwels, R., Stratis, A., Hedesiu, M., & Salmon, B. (2018) · Pediatric Radiology · doi:10.1007/s00247-017-4012-9 · Cited by 313
Krastl, G., Zehnder, M. S., Connert, T., Weiger, R., & Kühl, S. (2016) · Dental Traumatology · doi:10.1111/edt.12235 · Cited by 308
Gazzani, F., Ruellas, A. C. D. O., Faltin, K., Franchi, L., Cozza, P., Bigliazzi, R., Cevidanes, L. H. S., & Lione, R. (2018) · BioMed Research International · doi:10.1155/2018/2568235 · Cited by 17
Metadata
- Authors
- Ludlow, J. B., Timothy, R., Walker, C., Hunter, R., Benavides, E., Samuelson, D. B., & Scheske, M. J.
- Venue
- Dentomaxillofacial Radiology
- Publisher
- Oxford University Press (OUP)
- Published
- 2015-01
- Volume
- 44
- Issue
- 1
- Pages
- 20140197
- ISSN
- 0250-832X (ISSN-L)
- 1476-542X
- OpenAlex
- W2122612676
- Cited by
- 487
- References
- 23
- FWCI
- 27.25
- Type
- journal article
- Language
- en
- Open access
- green
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.