The DOI matches its Crossref record; 6 of the 6 references it cites were found in a registry or an index.
Deriving Hounsfield units using grey levels in cone beam computed tomography
Open accessAbstract
OBJECTIVES: an in vitro study was performed to investigate the relationship between grey levels in dental cone beam CT (CBCT) and Hounsfield units (HU) in CBCT scanners. METHODS: a phantom containing 8 different materials of known composition and density was imaged with 11 different dental CBCT scanners and 2 medical CT scanners. The phantom was scanned under three conditions: phantom alone and phantom in a small and large water container. The reconstructed data were exported as Digital Imaging and Communications in Medicine (DICOM) and analysed with On Demand 3D(R) by Cybermed, Seoul, Korea. The relationship between grey levels and linear attenuation coefficients was investigated. RESULTS: it was demonstrated that a linear relationship between the grey levels and the attenuation coefficients of each of the materials exists at some "effective" energy. From the linear regression equation of the reference materials, attenuation coefficients were obtained for each of the materials and CT numbers in HU were derived using the standard equation. CONCLUSIONS: HU can be derived from the grey levels in dental CBCT scanners using linear attenuation coefficients as an intermediate step.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Artifacts in CT: Recognition and Avoidance
Barrett, J. F., & Keat, N. (2004) · RadioGraphics · doi:10.1148/rg.246045065 · Cited by 1,688
Quantitative evaluation of bone density using the Hounsfield index.
Shapurian, T., Damoulis, P. D., Reiser, G. M., et al. (2006) · PubMed · Cited by 296
Evaluation of cross-section airway configuration of obstructive sleep apnea
Ogawa, T., Enciso, R., Shintaku, W. H., & Clark, G. T. (2007) · Oral Surgery, Oral Medicine, Oral Pathology, Oral Radiology, and Endodontology · doi:10.1016/j.tripleo.2006.06.008 · Cited by 271
Epoxy resin based tissue substitutes
White, D. R., Martin, R. J., & Darlison, R. (1977) · The British Journal of Radiology · doi:10.1259/0007-1285-50-599-814 · Cited by 252
Flat panel detector-based cone-beam volume CT angiography imaging: system evaluation
Ning, Y., Tang, X., Conover, D. L., et al. (2000) · IEEE Transactions on Medical Imaging · doi:10.1109/42.887842 · Cited by 138
Cone Beam Computed Tomography: An Innovative Tool for Airway Assessment
Osorio, F., Perilla, M., Doyle, D. J., & Palomo, J. M. (2008) · Anesthesia & Analgesia · doi:10.1213/ane.0b013e318172fd03 · Cited by 88
Cited by
Gignac, P. M., Kley, N. J., Clarke, J. A., Colbert, M. W., Morhardt, A. C., Cerio, D., Cost, I. N., Cox, P. G., Daza, J. D., Early, C. M., et al. (2016) · Journal of Anatomy · doi:10.1111/joa.12449 · Cited by 541
Imaging software accuracy for 3-dimensional analysis of the upper airway
Weissheimer, A., Menezes, L. M. D., Sameshima, G. T., Enciso, R., Pham, J., & Grauer, D. (2012) · American Journal of Orthodontics and Dentofacial Orthopedics · doi:10.1016/j.ajodo.2012.07.015 · Cited by 263
Metadata
- Authors
- Mah, P., Reeves, T. E., & McDavid, W. D.
- Venue
- Dentomaxillofacial Radiology
- Publisher
- Oxford University Press (OUP)
- Published
- 2010-09
- Volume
- 39
- Issue
- 6
- Pages
- 323-335
- ISSN
- 0250-832X (ISSN-L)
- 1476-542X
- OpenAlex
- W2068706683
- Cited by
- 371
- References
- 6
- FWCI
- 14.49
- Type
- journal article
- Language
- en
- Open access
- green
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Deriving Hounsfield units using grey levels in cone beam computed tomography. https://app.cochat.ai/papers/10.1259/dmfr/19603304
- The paper
- Mah, P., Reeves, T. E., & McDavid, W. D. (2010). Deriving Hounsfield units using grey levels in cone beam computed tomography. Dentomaxillofacial Radiology. https://doi.org/10.1259/dmfr/19603304
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.