Vibration Control of a Wind-Excited Benchmark Tall Building with Complex Lateral-Torsional Modes of Vibration
The DOI matches its Crossref record; 1 of the 1 references it cites were found in a registry or an index.
Abstract
This paper describes a proposed wind-excited benchmark tall building incorporating three-dimensional lateral-torsional modes of vibration, which is typical of a significant number of modern tall buildings. A series of wind tunnel pressure tests were conducted on a 1:400 scale model to determine the translational and torsional wind forces acting on the benchmark building. A finite element model was also constructed and mass, damping, and stiffness matrices were subsequently formulated as an evaluation model for numerical analysis. The evaluation model was further simplified to a state reduced-order system (ROS) using the state order reduction method. A numerical vibration control example was conducted to demonstrate the suppression of the wind-induced three-dimensional lateral-torsional motions using a bi-directional tuned mass damper (TMD) incorporating two magnetorheological (MR) dampers, one in each orthogonal direction, to act as a semi-active control system, referred to as a smart tuned mass damper (STMD). The optimal control forces generated by the MR dampers were obtained through the linear quadratic regulator (LQR) to minimize the storey accelerations. The formulation details, methodology and numerical simulation results are outlined in this paper.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Performance of tuned mass dampers under wind loads
Kwok, K. C. S., & Samali, B. (1995) · Engineering Structures · doi:10.1016/0141-0296(95)00035-6 · Cited by 206
Self-citation
Cited by
Research developments in vibration control of structures using passive tuned mass dampers
Elias, S., & Matsagar, V. (2017) · Annual Reviews in Control · doi:10.1016/j.arcontrol.2017.09.015 · Cited by 556
Wind-Induced Vibration Mitigation in Tall Buildings Using the Tuned Mass-Damper-Inerter
Giaralis, A., & Petrini, F. (2017) · Journal of Structural Engineering · doi:10.1061/(asce)st.1943-541x.0001863 · Cited by 330
Semi-active vibration absorber based on real-time controlled MR damper
Weber, F. (2014) · Mechanical Systems and Signal Processing · doi:10.1016/j.ymssp.2014.01.017 · Cited by 180
Metadata
- Authors
- Tse, K. T., Kwok, K. C. S., Hitchcock, P. A., Samali, B., & Huang, M. F.
- Venue
- Advances in Structural Engineering
- Publisher
- SAGE Publications
- Published
- 2007-06
- Volume
- 10
- Issue
- 3
- Pages
- 283-304
- ISSN
- 1369-4332 (ISSN-L)
- 2048-4011
- OpenAlex
- W2144115859
- Cited by
- 49
- References
- 1
- FWCI
- 12.48
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Vibration Control of a Wind-Excited Benchmark Tall Building with Complex Lateral-Torsional Modes of Vibration. https://app.cochat.ai/papers/10.1260/136943307781422208
- The paper
- Tse, K. T., Kwok, K. C. S., Hitchcock, P. A., Samali, B., & Huang, M. F. (2007). Vibration Control of a Wind-Excited Benchmark Tall Building with Complex Lateral-Torsional Modes of Vibration. Advances in Structural Engineering. https://doi.org/10.1260/136943307781422208
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.